• Title/Summary/Keyword: 두부CT

Search Result 140, Processing Time 0.025 seconds

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

A Case Report of Langerhans Cell Histiocytosis of Frontal Area (전두부에 발생한 랑게르한스세포 조직구증의 치험례)

  • Yang, Hae Won;Kang, Min Gu;Chang, Choong Hyun
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.1
    • /
    • pp.37-39
    • /
    • 2009
  • Purpose: Langerhans cell histiocytosis is a heterogenous group of Langerhans cell proliferative disorders and includes eosinophilic granuloma, Letterer-Siwe diseases, and Hand-Schuller Christian disease. We report a case of eosinophilic granuloma on frontal area. Methods: A 17-year-old male presented with swelling and tenderness on Lt. frontal and periorbital area. CT and MRI showed a $33{\times}25mm$ sized mass that involved Lt. frontal calvarium, frontotemporal meninges, and orbital roof. Results: Total excision of the mass and adjacent soft tissue, calvarium, and orbital roof was performed. Orbital roof defect was reconstructed with absorbable plate and calvarial defect was done with outer cortex of temporal bone flap. The histology revealed proliferation of histiocytes and eosinophils. Immunologically, these histiocytic cells expressed S-100 protein and CD1a. The patient is currently taking conservative treatment. Conclusion: The severity of these disease and their prognosis and treatments are various. For unifocal cranial Langerhans cell histiocytosis, complete excision is the treatment of choice. We report this case with review of literature.

Clinical Usefulness of MR FLAIR Image in Mild Head Injuries (경증 두부외상 환자에서 MR FLAIR 영상의 임상적 유용성)

  • Kim, Sei-Yoon;Whang, Kum;Kim, Hun-Joo;Lee, Myoung-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1182-1186
    • /
    • 2001
  • Objectives : MR fluid-attenuated inversion recovery(FLAIR) image uses paired long inversion time and relaxation time that nulls the signal from CSF. With nulling of the CSF long echo time readout could be used to increase T2-weighting, hence improving the conspicuousness of most tissue lesions without the deleterious effects of CSF artifact seen on T2 weighted sequence. We examed the usefulness of FALIR image in the diagnosis of mild head injury. Methods : A total of 38 patients with mild head injury were examined by FLAIR image. We compared those images with CT scan and T1, T2-weighted images. Careful observation of MR images were done by two well-trained neuroradiologists. Each image was compared for conspicuousness and detectability of traumatic lesions might have shown abnormal signal intensities. The Wilcoxon signed ranks test was used for statistical evaluation. Results : The FLAIR image was significantly more sensitive than those of other images(p<0.001). T2 FFE(Fast Field Echo) image was more useful for detection of small petechial hemorrhages. Conclusion : FLAIR image is considered to be more sensitive than those of conventional MR images in the evaluation of mild head injuries.

  • PDF

A Fatal Complication Associated with Combined Posterior Petrous and Suboccipital Approach to a Giant Jugular Foramen Schwannoma - A Case Report - (하후두부 접근법과 후경추체 접근법에 의한 거대 경정맥공 신경초종의 제거술과 동반된 합병증 - 증례보고 -)

  • Koh, Sung-Bum;Koh, Young-Cho;Yoo, Heon;Park, Si-Young;Park, Hyo-IL
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.9
    • /
    • pp.1144-1149
    • /
    • 2001
  • Schwannomas of the jugular foramen, originating from the glossopharyngeal nerve, vagus and accessory nerve represent approximately 0.17-0.72% of all intracranial tumor, and consists of 1.4-2.9% of all intracranial schwannomas. The clinical presentation of these tumors varies significantly according to originated nerve and it's growth pattern. Magnetic resonance(MR) image and temporal bone computed tomography(CT) scan have a major role for diagnosis of such tumor. The treatment of choice is total resection whenever possible. Generally, suboccipital approach is sufficient for the removal of the tumor, but in case with large size, combination of resection of petrous part of temporal bone with or without transection of sigmoid sinus is may be necessory. We have recently experienced one case of giant jugular foramen schwannoma and postoperative fatal complication in a 34-year-old male who was treated with combined posterior petrous and suboccipital approach with transection of sigmoid sinus

  • PDF

Non-Functioning, Malignant Pancreatic Neuroendocrine Tumor in a 16-Year-old Boy: A Case Report (16세 남아에서 발생한 췌장의 비기능성 악성 신경내분비 종양: 증례 보고)

  • Lim, Se-Woong;Lee, Young-Hwan;Choi, See-Sung;Cho, Hyun-Sun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • We report the case of a 16-year-old boy with a solid pancreatic mass which proved to be a nonfunctioning, malignant pancreatic neuroendocrine tumor (PNET). In pediatric patients, malignant pancreatic tumors are rare, especially malignant PNET. When dynamic contrast enhanced MRI showed a well enhancing solid pancreatic tumor on arterial and delayed phases and combined with malignant features, such as vascular invasion, invasion of adjascent organs, and lymphadenopathy, we should include malignant pancreatic neuroendocrine tumor in the differential diagnosis of childhood pancreatic tumors.

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

Availability of the Optic Nerve Sheath Diameter Measured by Using Ultrasonography as a Secondary Survey for Patient with Head Injuries in the Emergency Department (응급실에 내원한 두부외상환자의 2차 평가로써 초음파를 이용한 시각신경집 지름 측정은 유용한가?)

  • Lee, Dong Wook;Lee, Jung Won;Park, Sae Hoon;Park, Ihl Sung;Lee, Hyun Jung;Yoo, Byeong Dae;Moon, Hyung Jun
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.104-110
    • /
    • 2013
  • Purpose: Bedside ultrasonography is available in most emergency departments, and detecting the intracranial pressure is elevated is critical. Our objective is to evaluate the availability of bedside optic nerve ultrasound (ONUS) as a secondary survey for patients with head injuries in the emergency department (ED). Methods: From September, 2012, to March, 2013, we performed a prospective study of patients presenting to the ED after an accident. Patients with head injuries but without obvious ocular trauma or ocular disease were included. The ONUS was performed using a 3 to 12 MHz linear probe on closed eyelids after a primary survey. We analyzed the correlation between the brain computed tomography (CT) findings that suggested elevated intracranial pressure (ICP) and the Optic nerve sheath diameter (ONSD) measured by using ONUS. Results: A total of 81 patients were enrolled. Forty-seven had CT results consistent with elevated ICP, and their mean ONSD was $5.98{\pm}0.59$ mm; the mean ONSD of patients who showed no signs of elevated ICP on CT was $4.63{\pm}0.21$ mm. The sensitivity and the specificity for the ONSD, compared with elevated ICP, were 98.87% and 100%, respectively, when the cut-off value was set to 4.96 mm. The area under curve (AUC) was 0.997 in the receiver operating characteristic curve (ROC curve). Conclusion: An evaluation using ONUS is a simple noninvasive procedure and is a potentially useful tool as a secondary survey to identify an elevated ICP.

Re-conservation of the Iron Sword with Ring Pommel with Three-Pointed Leaf Decoration Excavated from Tomb No. 55 at the Dalseong Ancient Tomb Complex in Daegu and a Study of Its Production Method (대구 달성 55호분 출토 삼엽문이자태도의 재보존처리와 제작 기법 연구)

  • Lee, Huisung;Huh, Ilkwon;Ro, Jihyun;Park, Seungwon
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.1-16
    • /
    • 2020
  • This paper presents the process of re-conservation and the results of research on the production method of the Iron Sword with Ring Pommel with Three-Pointed Leaf Decoration, one of the excavation findings from Tomb No. 55 in the Dalseong Ancient Tomb Complex in Daegu. This iron sword is a double weapon with two large swords housed within a single sheath. Four smaller swords are attached to the surface of the sheath, two on the upper portion and the other two below. It is the only such two-in-one weapon excavated intact thus far from an ancient Korean tomb. The records show that it underwent conservation treatment twice in the past. In this study, it was subjected to conservation treatment again to replace the stiffener in some cracking areas, and its material, composition, and production method were analyzed by CT, XRF analysis, and stereoscopic microscopy. The sword is mainly made of copper, but the golden component contains both gold and mercury, which suggests that the copper was plated in gold using mercury amalgamation. The examination of the production methods indicates that it was intended more to demonstrate the authority of its owner rather than to serve any practical use. The two upper small swords on the sheath were made in the same manner as the main swords, and the two small lower swords were cut from a single metal sheet. The sheath was made by cutting two metal sheets. Supports were used to attach the two small swords to the upper portion of the sheath, while the lower portion of the sheath was slit to allow the other two small swords to be inserted into it. The ring pommels of the main swords have a three-pointed leaf decoration. As for the other designs, the handle of the main sword features a series of semicircles, the decorative bands on the sheath have waves in dots, and the fish tail of the sheath shows diagonal lines of dots.

FEM Analysis of the Effects of Mouth guard material properties on the Head and Brain under Mandibular Impact (구강보호장치의 재료적인 특성이 하악골 충격 시악골 및 두부에 미치는 영향에 관한 유한요소분석)

  • Kang, Nam-Hyun;Kim, Hyung-Sub;Woo, Yi-Hyung;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.325-334
    • /
    • 2008
  • Statement of problem & Purpose: The purpose of this study was to investigate the effect of a mouth guard material properties on the skull and brain when they were under impact loads on mandible. Material and methods: Two customized mouth protectors having different material propeerst ieach other were made for a female Korean who had no history of brain trauma, no cerebral diseases, nomal occlusion and natural dentition. The 3D finite element model of human skull and brain scanned by means of computed tomography was constructed. The FEM model of head was composed of 407,825 elements and 82,138 nodes, including skull, brain, maxilla, mandible, articular disc, teeth and mouth guard. The stress concentrations on maxillary teeth, maxilla and skull with two mouth guards were evaluated under oblique impact load of 800N onto mandibular 3 loading points for 0.1sec. And the brain relative displacement was compared in two different mouth guard materials under same condition. Result and Conclusion: The results were as follows; 1. In comparison of von Mises stress on maxillary teeth, a soft mouth guard material had significantly lower stress values on measuring point than a hard mouth protector materials (P < .05). 2. In comparison of von Mises stress on maxilla and skull, A soft mouth protector material had significantly lower stress values on measuring point than a hard mouth protector materials (P < .05). 3. For impact loads on mandible, there were more stress concentrated area on maxilla and skull with hard mouth guard than soft with mouth protector. 4. For impact loads on mandible, brain relative displacement had little relation with mouth guard material properties. In results of this study, soft mouth guard materials were superior to hard mouth guard materials for mandible impact loads for prevention of sports injuries. Although the results of this study were not enough to figure out the roles of needed mouth guard material properties for a human head, we got some knowledge of the pattern about stress concentration and distribution on maxilla and skull for impact loads with soft or hard mouth protector. More studies are needed to substantiate the relationship between the mouth guard materials and sports injuries.

A study on the bone thickness of midpalatal suture area for miniscrew insertion (미니스크류 식립 부위로서 정중 구개봉합부 골의 두께에 관한 연구)

  • Kyung, Seung-Hyun
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.63-70
    • /
    • 2004
  • The midpalatal suture area has some advantages for supporting miniscrews : it has no specific anatomical structure, it is composed of thick cortical bone, and covered with attached gingiva. So it is suitable area for inserting miniscrews. However, the midpalatal suture area appears thinner when seen in ceph. As a result, Clinicians can misunderstand that inserting miniscrews cause the problem, both the risk of perforation and the decrease of stability. The purpose of this article is measuring the vertical bone thickness of the midpalatal suture area for inserting miniscrews. The total of 25patient (male : 13, female : 12), who are in their twenties, were taken CT. The vertical bone thickness of the midpalatal suture area was measures from the transverse section of CT. As a result, We reached a conclusion from the differences of each area. It is as follows: 1. There is no significant difference between the thickness of male group and that of female group. 2. In coronal section, Bone thickness becomes thinner from the midpalatal suture to Left & Right side, in sagittal section, Bone thickness becomes thinner from incisive foramen to PNS. 3. The area that is within 3mm of left and right from the midpalatal suture area transversely and within 25mm backward from the incisive foramen sagittaly is enough for inserting miniscrews.