• Title/Summary/Keyword: 두부 CT검사

Search Result 55, Processing Time 0.03 seconds

Neuropsychiatric Evaluation of Head-Injured Patients(I) : Comparison of Structural and Functional Brain Studies in Post-Traumatic Organic Mental Disorder (두부외상 환자의 신경정신의학적 평가(I) : 외상후 기질성정신장애 환자에서 뇌의 구조적 및 기능적 검사소견의 비교)

  • Yi, Jang Ho;Chang, Hwan-Il
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.57-65
    • /
    • 1996
  • The Evaluation of patients complaining of psychiatric symptoms following head injury is much affected by the results of various tests. The objecive of this paper is to investigate the effectiveness of each lest by comparing the structual and fuctional brain studies. The subjects were 93 organic menial disorder in and out patients at the Dept. of Neuropsychiatry of the Kyung Hee University Hospital. After carrying out MRI, CT, SPECT, EEG, the results of each were analysed for the sesitivity and ability to detect focal lesion. The degree of inter-test correlations of lest results were also investigated. Furthermore, the characteristic features of psychological tests were studied and the relationship between each of above mentioned tests and psychological test was examined. As for the test sensitivity to diagnosis, the SPECT was the most superior followed by MRI, CT, EEG in thai order. In the case of abnormality, SPECT ranked 1st in detection of focal lesion, followed by MRI, CT in that order. In the inter-test result correlation, the correlation of SPECT-MRI was statistically significant. When mare than moderate abnormality EEG finding was reported, it correlated significantly with that of MRI findings. In the MMPI, the average scores on F, Hs, D, Hy, Pa, Pt, Sc subscales were above 60. Abnormal SPECT group scored significantly high on the F, Pd, Pa, Sc, Ma scales and therefore in comparison ot the SPECT normal group, displayed more psychotic features. In K-WAIS, the mean full scale IQ was down to 77. 23(Verbal IQ : 78.76, Performance IQ : 77.44) but there was no characterogic significant relationship between the lowered to and abnormal SPECT, MRI, CT and EEG results. In conclusion, 1) The SPECT was mast superior in sensitivity and detection of focal lesions. In comparision with other tests, the results of SPECT correlated well with MRI had thus is thought to be very usefull testing method in the evaluation of organic mental disorder patients. 2) The MRI had relatively high sensitivity, ability to detect focal lesion and superior correlation with other test. 3) Although EEG fared less an sensitivity in comparison to other tests, the results of above moderate abnormal grade group and that of MRI correlated significantly. 4) In the MMPI highly scored in F, Hs, D, Hy, Pa, Pt, Sc subscales and abnormal SPECT patients were shown to display more sever psychotic features. There was no significant character relationship between the lowered IQ(in K-WAIS) and abnormal findings on MRI, CT, SPECT, EEG.

  • PDF

Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL) (전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로)

  • Lee, Seoyoung;Kim, Kyunglee;Ha, Hyekyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 2013
  • In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were $1.0058{\pm}0.0074$. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

National Data Analysis of General Radiography Projection Method in Medical Imaging (영상의학검사 일반촬영 분야의 촬영기법에 대한 분석)

  • Kim, Jung-Su;Kim, Jung-Min;Lee, Young-Han;Seo, Deok-Nam;Choi, In-Seok;Nam, So-Ra;Yoon, Yong-Su;Kim, Hyun-Ji;Min, Hye-Lim;Her, Jea;Han, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • According to database of medical institutions of health insurance review & assessment service in 2013, 1118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

Correlation between Cephalhematomas and Intracranial Hematomas (신생아 두혈종과 두개내 혈종과의 연관성)

  • Park, Sun-Min;Oh, Ki-Won;Kim, Heng-Mi
    • Neonatal Medicine
    • /
    • v.15 no.2
    • /
    • pp.160-165
    • /
    • 2008
  • Purpose : Cephalhematomas rarely lead to serious complications, such as skull fractures and intracranial hematomas, so CT and/or MRI scans are indicated only in cases in which depressed fractures are suspected or neurologic symptoms develop. Nevertheless, we have experienced several cases of cephalhematomas associated with intracranial hematomas in the absence of remarkable neurologic symptoms. The aim of this study was to evaluate the correlation between cephalhematomas and intracranial hematomas and determine the need for neuroimaging in infants with cephalhematomas. Methods : Infants who were admitted to the NICU with cephalhematomas and underwent neuroimaging (CT and/or MRI) between January 2002 and July 2006 were evaluated. Neuroimaging was done when the symptoms suggested the development of an intracranial hematoma. Results : Among 54 infants with cephalhematomas, 18 infants underwent neuroimaging. Six of 18 infants (33.3%) had intracranial hematomas, 4 infants had epidural hematomas, and 2 infants had subdural hematomas. Four of these 6 infants had neurologic symptoms or depressed skull fractures; 2 infants had no neurologic symptoms or depressed skull fractures. The neuroimaging was done to evaluate the cause of an excessive elevation of serum bilirubin and unexplained anemia. There were no remarkable differences between the infants with and without intracranial hematomas with respect to gestational age, birth weight, head circumference, diameter of the cephalhematoma, neurologic symptoms, and other clinical signs and symptoms. Conclusion : Based on this study, intracranial hematomas are common complications of cephalhematomas, thus more careful inspection and neuroimaging may be needed in cases of cephalhematomas in newborns.

Comparison of Cervical Lymphadenitis as First Presentation of Kawasaki Disease and Acute Unilateral Cervical Lymphadenitis (경부 림프절염로 발현된 가와사키병과 급성 편측 경부 림프절염의 비교)

  • Lee, Hoon Sang;Kim, Ji Yong;Song, Bo Kyung;Kim, Yong-Woo;Park, Su Eun
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.3
    • /
    • pp.217-222
    • /
    • 2016
  • Purpose: This study aimed to identify the differential clinical, laboratory, and imaging characteristics between patients with cervical lymphadenitis as first presentation of Kawasaki disease (CLKD) and those with acute unilateral cervical lymphadenitis (AUCL). Methods: We surveyed 372 patients who visited Pusan National University Children's Hospital because of fever and cervical lymph node enlargement, and underwent neck computed tomography (CT) from January 2010 to December 2014. We compared 28 confirmed cases of Kawasaki disease and 28 cases of AUCL based on a retrospective review of the medical records of the patients. Results: Patients with CLKD and AUCL showed no differential clinical characteristics in terms of the duration of fever, antibiotic use, or the size of lymph nodes. Patients with CLKD had higher white blood cell count, absolute neutrophil count, erythrocyte sedimentation rate, and C-reactive protein levels (P<0.05) than those of patients with AUCL. The presence of retropharyngeal edema on neck CT was similar between the groups (64% vs. 33%, P=0.686). Conclusions: CLKD and AUCL showed no differentiating clinical and radiological characteristics; hence, Kawasaki disease should be the presumptive diagnosis in patients with fever and cervical lymph node enlargements who fail to respond to antibiotic treatment.

Preliminary Research on the Implementation of Information of Human Facial Part Required for the 3D Printing of Eye Shield (안구차폐체 제작에 필요한 안면부 3차원 정보 구현의 기초연구)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.955-960
    • /
    • 2019
  • The Computed tomography (CT) scan can have high radiation in a few tests, and this risk is significant given that it is often repeated in one patient. In children, the incidence of radiation-induced cancer is reported because organs are growing, are more sensitive to radiation. 3D printing has recently been studied to be applied to various applications as a research field for 3D printing applications, research on fabrication of radiation shields and materials has been conducted. The purpose of the 3D printer is to replace the existing panel-type shields and to make customized designs according to the shape of the human body. Therefore, research on 3D information processing to be input to the 3D printer is also necessary. In this study, 3D data of the human body surface, which is the preliminary step of the manufacture of patient-specific eye shield using stereo vision depth map technology, was studied. This study aims to increase the possibility of three-dimensional output. As a result of experimenting with this method, which is relatively simple compared with other methods of 3D information processing, the minimum coordinates for 3D information are extracted. The results of this study provided the advantages and limitations of stereo images using natural light and will be the basic data for the manufacture of eye shields in the future.

Influence of Regularization Parameter on Algebraic Reconstruction Technique (대수적 재구성 기법에서 정규화 인자의 영향)

  • Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.679-685
    • /
    • 2017
  • Computed tomography has widely been used to diagnose patient disease, and patient dose also increase rapidly. To reduce the patient dose by CT, various techniques have been applied. The iterative reconstruction is used in view of image reconstruction. Image quality of the reconstructed section image through algebraic reconstruction technique, one of iterative reconstruction methods, was examined by the normalized root mean square error. The computer program was written with the Visual C++ under the parallel beam geometry, Shepp-Logan head phantom of $512{\times}512$ size, projections of 360, and detector-pixels of 1,024. The forward and backward projection was realized by Joseph method. The minimum NRMS of 0.108 was obtained after 10 iterations in the regularization parameter of 0.09-0.12, and the optimum image was obtained after 8 and 6 iterations for 0.1% and 0.2% noise. Variation of optimum value of the regularization parameter was observed according to the phantom used. If the ART was used in the reconstruction, the optimal value of the regularization parameter should be found in the case-by-case. By finding the optimal regularization parameter in the algebraic reconstruction technique, the reconstruction time can be reduced.

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.