• Title/Summary/Keyword: 두부 팬텀

Search Result 46, Processing Time 0.02 seconds

A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography (디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰)

  • Yeon-Jin, Jeong;Young-Cheol, Joo;Dong-Hee, Hong;Sang-Hyeon, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.897-904
    • /
    • 2022
  • The purpose of this study is to compare the difference in dose and image quality when applying the diagnostic reference level (DRL) test conditions for head radiography in a digital radiation environment and the test conditions currently applied in clinical practice. I would like to review the conditions of radiographic examination. In this study, the head model phantom was targeted, and the investigation conditions were divided into clinical conditions (Clinic), DRL value (DRL75), and DRL average value (DRLmean). For dose, Enterance surface dose (ESD) was measured, and for image quality, signal-to-noise ratio and contrast-to-noise ratio were measured and analyzed for comparison. The average values of skull anterior posterior(AP) ESD according to the changes in test conditions were Clinic 1214.03±4.21 µGy, DRL75 3017.83±8.14 µGy, DRLmean 2283.50±7.09 µGy, and skull lateral (Lat). The average value of ESD was statistically significant with Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, and DRLmean 1654.43±6.48 µGy (p<0.01). The average values of SNR and CNR measured in the orbital, maxillary sinus, frontal sinus, and sella turcica were statistically significant (p<0.01). As a result of this study, compared to DRL, the conditions used in clinical practice showed lower dose levels of about 58% for AP and about 70% for Lat., and there was no qualitative difference in terms of image quality. Through this study, it is necessary to consider a new diagnostic reference level suitable for the digital radiation environment, and it is considered that the dose should be reduced accordingly.

Influence of Regularization Parameter on Algebraic Reconstruction Technique (대수적 재구성 기법에서 정규화 인자의 영향)

  • Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.679-685
    • /
    • 2017
  • Computed tomography has widely been used to diagnose patient disease, and patient dose also increase rapidly. To reduce the patient dose by CT, various techniques have been applied. The iterative reconstruction is used in view of image reconstruction. Image quality of the reconstructed section image through algebraic reconstruction technique, one of iterative reconstruction methods, was examined by the normalized root mean square error. The computer program was written with the Visual C++ under the parallel beam geometry, Shepp-Logan head phantom of $512{\times}512$ size, projections of 360, and detector-pixels of 1,024. The forward and backward projection was realized by Joseph method. The minimum NRMS of 0.108 was obtained after 10 iterations in the regularization parameter of 0.09-0.12, and the optimum image was obtained after 8 and 6 iterations for 0.1% and 0.2% noise. Variation of optimum value of the regularization parameter was observed according to the phantom used. If the ART was used in the reconstruction, the optimal value of the regularization parameter should be found in the case-by-case. By finding the optimal regularization parameter in the algebraic reconstruction technique, the reconstruction time can be reduced.

Evaluation the absorbed dose in brain of dental radiography (치과방사선 검사에서 두부(brain)의 흡수선량 평가)

  • Jeon, Woon-Sun;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.343-349
    • /
    • 2011
  • This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.

Comparison of Linac-based VMAT Stereotatic Radiosurgery and Conventional Stereotatic Radiosurgery for Multiple Brain Lesions (Linac 기반 VMAT 정위적 수술 뇌 병변 연구와 기존의 정위적 방사선 수술 비교)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.239-246
    • /
    • 2021
  • Portal Dosimetry was verified using EPID to secure the clinical application and reliability of the existing research dose evaluation. The dose distribution of Geant4 was compared with the measured value by 360° rotational irradiation with a 2.5 cm cone for stereotactic brain surgery. To confirm the dose distribution of patients with brain metastasis, the dose distribution investigated by inserting a Gafchromic EBT film into the parietal phantom and the dose distribution obtained from the parietal phantom using VMAT are compared and applied to actual patients. As a result of the analysis, it was confirmed that the accuracy of the beam center and the center of the couch coincide accurately with an error within 1mm as a result of QA through a pin ball. In addition, it was confirmed that the EBT3 film has excellent linearity in the range of 0 to 10 Gy according to various dose irradiation. In the same setting as the two cervical phantoms, we confirm that the implementation and simulation results calculations of dose calculations based on Geant4 using photon beams match the experimental data within the treatment planning volume (PTV). Therefore, volume modulated arc treatment (VMAT) 360° rotational irradiation was performed, and the result of iso-dose distribution analysis by rotational irradiation confirmed that it is appropriate to include a virtual tumor.

Usefulness Evaluation of Algorithm Conversion Method for Dose Reduction in Brain CT Examination (두부 CT 검사에서 선량감소를 위한 알고리즘 변환방법의 유용성 평가)

  • Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.481-487
    • /
    • 2019
  • Based on the scan conditions and algorithms that are generally applied during examinations during head CT examinations, the results of dose reduction through the application of algorithm changes were investigated through experiments. As a result, the dose reduction effect was more meaningful for the change of perfusion than for the tube voltage, and the quality evaluation using the brain phantom was relatively less reduced when the dose was reduced after the application of the Bone algorithm, especially for the application of the Bone algorithm, and the deviation of the mean CT number or Pixel value was measured relatively significantly. In other words, the conditions under which dose was reduced and quality was maintained to reduce the patient's exposure dose and obtain images of the same quality were obtained with the application of the Smooth algorithm and the resulting values of 120 kVp, 160 mA. At this point, doses were reduced by about 28%, and the mean CT number or Pixel value was also measured with relatively little error. If the results are applied to patients who visit the hospital for examination or follow-up after applying various algorithms and follow up scan conditions, the results are considered to be very useful in reducing patient exposure dose.

Evaluation of Image Noise and Radiation Dose Analysis In Brain CT Using ASIR(Adaptive Statistical Iterative Reconstruction) (ASIR를 이용한 두부 CT의 영상 잡음 평가 및 피폭선량 분석)

  • Jang, Hyon-Chol;Kim, Kyeong-Keun;Cho, Jae-Hwan;Seo, Jeong-Min;Lee, Haeng-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.357-363
    • /
    • 2012
  • The purpose of this study on head computed tomography scan corporate reorganization adaptive iteration algorithm using the statistical noise, and quality assessment, reduction of dose was evaluated. Head CT examinations do not apply ASIR group [A group], ASIR 50 applies a group [B group] were divided into examinations. B group of each 46.9 %, 48.2 %, 43.2 %, and 47.9 % the measured in the phantom research result of measurement of CT noise average were reduced more than A group in the central part (A) and peripheral unit (B, C, D). CT number was measured with the quantitive analytical method in the display-image quality evaluation and about noise was analyze. There was A group and difference which the image noise notes statistically between B. And A group was high so that the image noise could note than B group (31.87 HUs, 31.78 HUs, 26.6 HUs, 30.42 HU P<0.05). The score of the observer 1 of A group evaluated 73.17 on 74.2 at the result 80 half tone dot of evaluating by the qualitative evaluation method of the image by the bean curd clinical image evaluation table. And the score of the observer 1 of B group evaluated 71.77 on 72.47. There was no difference (P>0.05) noted statistically. And the inappropriate image was shown to the diagnosis. As to the exposure dose, by examination by applying ASIR 50 % there was no decline in quality of the image, 47.6 % could reduce the radiation dose. In conclusion, if ASIR is applied to the clinical part, it is considered with the dose written much more that examination is possible. And when examination, it is considered that it becomes the positive factor when the examiner determines.

Dosimetric Analysis for Human Exposure to Body-Mounted Wireless Devices (인체 착용형 휴대 단말기에 대한 노출량 해석 연구)

  • Park Min-Young;Ko Chae-Ok;Kim Jeong-Ran;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.207-212
    • /
    • 2006
  • A variety of wireless devices are commercially available now. Most of studies, however, have been directed to the biological effects of mobile-phone EMF. In this paper, dosimetric analysis for wireless devices of head-mounted display type and a wristwatch type were made to investigate possible biological effects of these devices. SAR(Specific Absorption Rate) distributions were calculated using FDTD(Finite Difference Time Domain) method, for adult human models such as standard Korean human model and VHP(Visible Human Project) model, as well as scaled child models. Measurements were also performed for SAM phantom wearing a simplified prototype for a wireless device for validation of the simulation results. It has been found that children are more vulnerable to such exposure, and these devices could cause some biological effects even for relatively lower power compared to conventional mobile pones.

Neutron Generation from a 24 MV Medical Linac (24 MV 의료용 선형가속기의 중성자 발생에 관한 연구)

  • Jeong Dong Hyeok;Kang Jeong Ku;Lee Jeong Ok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • The energy spectra and dose calculations were performed for secondary neutrons from a 24 MV LINAC using MCNPX code (V2, 4, 0). The energy spectra for neutrons and photons emitted from the LINAC head, and absorbed dose to water were calculated in water phantom. The absorbed doses calculated with Monte Carlo were $0.66\~0.35$ mGy/photon Gy at the surface to d=5 cm, and calculated with interaction data was 0.52 mGy/photon Gy at the depth of electron equilibrium in water. We have shown that this work can be applied to dose estimation of neutrons from high energy LINAC through the comparison of our results with other results.

  • PDF

A Study on the Additional Absorbed Dose of Normal Tissues by Image Guided Radiation Therapy(IGRT) (영상유도 방사선 치료(IGRT)에 따른 정상 조직의 추가 피폭에 대한 연구)

  • Kim, Gha-Jung;Ryu, Jun-Min;Choi, Jun-Gu;Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.75-81
    • /
    • 2016
  • The recent radiation therapy field can provide treatment which guarantees a high degree of accuracy, due to patient set-up using various image guided radiation therapy(IGRT) instruments. But the additional absorbed dose to patient's normal tissues is increasing. Therefore, this study measured the absorbed dose to surrounding normal tissues which is caused by patient set-up using OBI, CBCT, ExacTrac, among various IGRT instruments. The absorbed dose to the head, the chest, the abdomen, and the pelvis from CBCT was 12.57 mGy, 20.82 mGy, 82.93 mGy, and 52.70 mGy, respectively. Also, the absorbed dose from OBI and ExacTrac ranged from 0.76 to 8.58 mGy and from 0.14 to 0.63 mGy, respectively. As a result, CBCT's absorbed dose was far higher than other instruments. CBCT's surface dose was far higher than others, too, but OBI's entrance skin dose was almost the same as CBCT's.

Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography (CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과)

  • Jung, Mi-Young;Kweon, Dae-Cheol;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.307-312
    • /
    • 2009
  • The purpose of our study was to determine the eyeradiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lensshielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eyewith the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lenswithout qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  • PDF