• Title/Summary/Keyword: 두부방사선

Search Result 545, Processing Time 0.021 seconds

Comparison of midsagittal reference plane in PA cephalogram and 3D CT (3차원 전산화 단층촬영의 Nasion, Sella, Basion으로 구성된 정중 시상 평면과 정면 두부방사선 규격사진의 정중 시상 평면 비교)

  • Cho, Jin-Hyoung;Moon, Ji-Yeon
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 2010
  • Objective: The aim of this study is to find the most helpful midsagittal reference plane for diagnosis in PA cephalometry compared with 3D CT. Methods: The subjects consisted of 25 adults who showed no facial asymmetry by gross inspection. 3D CT and posteroanterior cephalogram of the subjects were taken. To find the most helpful midsagittal reference plane in PA cephalometry, we considered five kinds of midsagittal planes from which the distances to five landmarks were measured and compared the result with that of 3D CT. The midsagittal plane for 3D CT was determined by the landmarks Nasion, Sella and Basion. Results: PA measurements using the midsagittal reference plane on a perpendicular plane lying through the midpoint of the right and left latero-orbitales was closest to those of 3D CT. Conclusions: It was considered that latero-orbitale perpendicular could be used as the helpful midsagittal reference plane to assess facial asymmetry in PA cephalometry.

A comparative study of guiding methods for natural head posture in cephalometrics (두부방사선규격사진 촬영 시 유도방법에 따른 자연두부자세의 차이 및 재현성에 관한 연구)

  • Song, Jin-Myoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.341-350
    • /
    • 2005
  • The Purpose of this study was to compare the degree of vortical head rotation and to evaluate the reproducibility of natural Head posture (NHP) according to two guiding methods, the head posture aligner (HPA) method and the solf balance posture (SBP) method. The subjects consisted of 30 adults. On the first day. lateral and frontal cephalometric radiographs were obtained through the two guiding methods. One mouth later. lateral and frontal cephalometric radiographs were obtained again through both guiding methods. The degrees of vertical head rotation of both guiding methods were compared and the reproducibility was evaluated for each guiding method. A comparison of the degrees of vortical head rotation for the two methods revealed that the vertical head posture was lower in the SBP method than in the HPA method by an average of $2.79^{\circ}$. All measurements obtained using the HPA and SBP methods with a time interval of one north did not show any significant difierence in lateral and frortal cephalometric radiographs. The results of the present study suggest that the SBP method may be used as an alternative to the HPA method in case the HPA method can not be applied.

THE USE OF POSTEROANTERIOR CEPHALOGRAM IN ORTHODONTICS (교정에서의 정모 두부 방사선 규격 사진의 이용)

  • Kim, Young Joon;Rhu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.165-175
    • /
    • 1989
  • In evaluation of some area within the craniofacial complex posteroanterior cephalogram together with lateral cephalogram is used for assessment of the exact existence and posture by grasping 3-dimensional concept. The usages of posteroanterior cephalogram in orthodontics are following; 1. The use during diagnosis and treatment planning 1) Assessment of the area and amount of facial asymmetry. 2) Assessment of therapeutic position for diagnosis and treatment 2. The Assessment of success in orthodontic mechanics If we use posteroanterior cephalogram together with lateral cephalogram adequately and simultaneously we can establish the exact diagnosis and appropriate treatment planning.

  • PDF

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

Digital imaging of film-based cephalograms using a digital camera (디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환)

  • Wang, Sung-Jin;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.448-457
    • /
    • 2004
  • As computer Programs for cephalometric analysis were developed in diagnosis & treatment planning, digital imaging of film-based cephalograms came to be needed. When a digital camera is used, a problem encountered the image distortion produced according to the focal length, which causes errors in indentifying landmarks. In addition, changes in the image size and compression ratio will inevitably produce a low quality image, causing errors in identifying landmarks. Hence. we have found the focal length producing the least image distortion when digital imaging the film-based cephalograms and the minimal digital camera setting which helps to identify the correct landmarks using the COOLPIX4500 digital camera (Nikon, Japan). The results were as follows The image distortion was minimized at a focal length of 16.4mm (79.4mm when converted into a 35mm film camera) when digital imaging the film-based cephalograms. When wide imaging, with a focal length of under IS.4mm, barrel distortion was found and when tole imaging. with a focal length of over 15.4mm pincushion distortion was found. The minimal digital camera setting was $2272{\times}1704$ pixel at normal (1/8) compression from which we can identify the correct landmarks at the same level as tracing the film-based cephalograms manually. As a result. when digital imaging the film-based cephalograms, using a COOLPIX4500 digital camera (Nikon, Japan), the focal length should be 16.4mm the pixel image size over $2272{\times}1704$, and the compression ratio over normal (1/8).

A study on the correlations between facial biotype, submentovertex cephalometric measurements and surface EMG activity in patients with facial asymmetry (안면 비대칭 환자의 수직 안모 유형과 이하두정 두부방사선 규격사진 계측치 및 표면 근전도의 상관성에 대한 연구)

  • Kim, Seong-Soo;Lee, Nam-Ki;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.218-227
    • /
    • 2006
  • Although the submentovertex radiograph and surface EMG are not often used due to the difficulty of interpretation, they are accepted as useful diagnostic and analytic aids for skeletal asymmetry. There have been reports which state that they were also useful for the evaluation of vertical skeletal relations. The purpose of this study was to evaluate the correlations between EMG data, measurements from submentovertex radiographs, facial types and facial asymmetry following examination of 60 asymmetric patients. The radiographic corpus length were greater in the nonaffected sides (p<0.001), gonion to interspinosum axis were greater in the affected sides and the mandibular condyle and gonion were located more anteriorly in the non-affected sides than in the affected sides but not significant (p=0.07). The activity of the anterior temporal muscle in rest position was higher in the affected sides than in the non-affected sides (p<0.01). The activity of the masseter muscle at maximum clenching was found to be nonsignificant but it was higher in the affected sides than in the non-affected sides (p=0.09). There was positive correlation between facial index and the intercondylar axes angle (p<0.01). There was positive correlation between masseter muscle activity in maximum occlusion and facial index in the affected and non-affected sides (p<0.05). The results demonstrate that the submentovertex radiograph and EMG can provide useful information for the evaluation of horizontal and vertical skeletal relations.

The comparative study of three-dimensional cephalograms to actual models and conventional lateral cephalograms in linear and angular measurements (3차원 두부방사선규격사진의 정확성에 관한 연구 -실제 계측 및 측모 두부방사선 규격사진 계측과의 비교-)

  • BAE, Gi-Sun;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.129-140
    • /
    • 1997
  • Conventional cephalometrics have inherent errors because their evaluation is performed in two-dimension for threedimensional object. To compensate these errors, three-dimensional cephalograms - derivation of three-dimensional data from conventional lateral and postero-anterior cephalograms - were developed. In this study, the accuracy and precision of three dimensional cephalograms were determined by means of 10 linear and 12 angular measurements on 36 acrylic skull models and by the comparison of conventional lateral cephalograms. The results were as follows 1. Mean difference between three-dimensional cephalograms and actual models in linear measurements was $0.94{\pm}0.62mm$ and mean rate of magnification of three-dimensional cephalograms was $100.31{\pm}0.91%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in linear measurements(${\alpha}=0.1$). 2. Mean difference between conventional lateral cephalograms and actual models in linear measurements was $6.44{\pm}1.48mm$ and mean rate of magnification of lateral cephalograms was $106.99{\pm}1.45%$. There were statistically significant differences between lateral cephalograms and actual models in linear measurements(P<0.005). 3. Mean difference between three-dimensional cephalograms and actual models in angular measurements was $1.22{\pm}0.82^{\circ}$ and mean rate of magnification of three-dimensional cephalograms was $105.71{\pm}12.07%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in angular measurements(${\alpha}=0.1$). 4. Mean difference between conventional lateral cephalograms and actual models in angular measurements was $1.70{\pm}0.94^{\circ}$ and mean rate of magnification of lateral cephalograms was $106.35{\pm}15.70%$. There were no statistically significant differences between lateral cephalograms and actual models in angular measurements(${\alpha}=0.1$). There were similarity between three-dimensional and lateral cephalograms in angular measurements.

  • PDF

EVALUATION OF THE REPRODUCIBILITY IN CEPHALOGRAPHY USING ROENTGENOCEPHALOMETRICS AND PHOTOGRAPHIC SUBTRACTION (두부방사선 계측과 Photographic subtraction을 이용한 측모 두부방사선 규격사진의 재현성에 관한 연구)

  • Jeon Seon-Doo;Nha Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.347-359
    • /
    • 1994
  • The reproducibility of cephalography in repeated exposures were studied by tracing and photographic subtraction. The materials consisted of 50 pairs of 'same day' radiograph taken under identical conditions. The evaluation included skull, cervical column, hyoid bone, pharynx, tongue, soft tissue profile resulting 43 items in tracing, and 19 items in photographic subtraction. The results obtained from the differences between each pair were as follows: 1. The means and standard deviations by tracing of skull, cervical column, hyoid bone, pharynx, tongue, soft tissue profile were 0.34±0.62㎜, 1.02±1.59㎜, 1.37±1.78㎜, 0.55±1.16㎜, 0.51±1.51㎜, 0.15±0.3㎜ each. 2. The means and standard deviations by photographic subtraction of skull, cervical column, hyoid bone, pharynx, tongue were 0.09±0.35㎜, 0.70±0.95㎜, 1.22±1.33㎜, 0.53±0.86㎜, 0.27±0.41㎜ each.

  • PDF