• Title/Summary/Keyword: 동축케이블

Search Result 102, Processing Time 0.023 seconds

Internal Hook-shaped Patch Antenna for Multiband Wireless USB Dongle Applications (다중대역 무선 USB 동글용 내장 Hook형 안테나)

  • Jeong, Seong-Jae;Hwang, Keum-Cheol;Shin, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.11
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, an internal USB dongle antenna with a circular hook-shaped patch is proposed. The proposed antenna comprises of a circular hook-shaped patch and a monopole stub. The proposed antenna with the dimension of $10mm{\times}50mm{\times}0.8mm$ was fabricated on commercial FR-4 substrate with a dielectric constant of 4.6 and tangent loss of 0.025. The designed antenna exhibits three different resonant bandwidths, 2.4 GHz-2.5 GHz, 3.4 GHz-3.6 GHz, and 5.15 GHz-5.825 GHz. The measured radiation patterns are omni-directional at measured frequencies. Therefore, the proposed antenna is suitable for wireless USB dongle antenna that can support multiband wireless services such as WLAN, WiMAX and Bluetooth.

Impedance Characteristics of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 임피던스 특성)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.67-78
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power line for power line communication (PLC) is analyzed. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the equivalent model and basic transmission line theory, input impedance at the signal induction part is calculated. And also calculated input impedance of power line itself that the medium voltage coupler and coaxial cable effect are removed. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power line itself is between $200\;{\Omega}\;and\;300\;{\Omega}$ and converges to a half of their characteristic impedance with increasing frequency. And also measured data is very similar to calculated data.

Effective Installation Methods of Down Conductors in Lightning Protection Systems (뇌보호시스템에서 인하도선의 효과적인 설치기법)

  • 이복희;엄주홍;이승칠;강성만
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.8-14
    • /
    • 2002
  • A modern lightning protection system is required to eliminate the risks such as electrical shocks and damages of structures, electrical and electronic equipments due to lightning. However, the conventional lightning protection systems play and important role in protecting persons and structures only. Thus an effective lightning protection system is indispensable today in computer, information and communication facilities and etc. The mafor objective of this paper is to develop the technology to protect electronics and computerized facilities against lightning-caused overvoltages. The study is oriented on the control of the potential rise of down conductors with the type and installation method of down conductors. As a result, to reduce side flashes and hazards caused by the potential rise of down conductor due to lightning current, the coaxial cable with a low characteristic impedance and high insulation level is suitable for a down conductor. In particular it is extremely effective to bond down conductors to the steel supporter, metal raceways and steel frame of structures.

Implementation of PLC-Based Multi-modem for Process Automation of Non-destructive Inspection (비파괴검사 공정자동화를 위한 전력선통신 기반 복합통신장치의 구현)

  • Jung, Jun Hwan;Jun, Ho Ik;Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.822-828
    • /
    • 2013
  • In this paper, a multi-modem for process automation of non-destructive inspection (NDI) which possibly generates various kinds of data is implemented and verified. Here, a variety of data such as control signals, text data, image data generated by inspection devices, sensors, computers are transmitted to the multi-modem via serial, Ethernet, and coaxial cable. We exploit a communication network in which powerlines are used as backbone transmission media. Thus, the implemented multi-modem has various ports and corresponding interfaces for data transmission. As a result of practical experiments, the multi-modem maintains almost constant data rate with little waveform distortion. In addition, the experiments confirm that the modem operates normally under extreme variation of temperature. It is, therefore, considered that the multi-modem can contribute significantly to implement powerline communication (PLC)-based process automation for NDI in which various kinds of data are practically generated.

A Study on the Convergence of CATV Networks for Ultra High Speed Internet Service (초고속 인터넷 서비스를 위한 CATV 망의 융복합 연구)

  • Park, Yong-Seo
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.219-224
    • /
    • 2015
  • The broadcasting communications service will accelerate its development with the convergence of broadcasting media and internet service. In the field of CATV network related technology, only those service providers will be able to survive in future, and they can combine available services in the most effective and economical way. This research aims to explain the CATV status of Korea and China and its technology trends. It also analyzes CMC(Cable Modem Concentrator) technology, suggested as one of the high-speed internet technology. CMC technology has the advantages of enhancing the transmission speed while using the existing basic structure of HFC network and expanding service area by adding amplifiers within CMC. The distance between coaxial cables is getting shorter with more concentrated areas in large cities in Korea. However, in China, the demand for long distance transmission service is increasing. CMC technology satisfies both short and long distance service subscribers without any geographical limitations. With these advantages, CMC technology is expected to generate lots of economic benefits if applied for the CATV network in the area of China, Middle East, and Southeast Asia.

Design of lumped six-port phase correlator and performance of lumped direct conversion receiver (집중 소자형 6단자 위상 상관기 설계와 집중 소자형 직접변환 수신 성능)

  • Yu, Jae-Du;Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1071-1077
    • /
    • 2010
  • The six-port phase correlator using lumped elements was designed and fabricated in this paper, also the receiving performance of L-band direct conversion receiver using lumped six-port phase correlator element was analyzed. The proposed L-band lumped six-port phase correlator element was composed of a resistive power divider and the twist-wire coaxial cables. The proposed lumped six-port structure provides the small-sized configuration and wide-band characteristics. The performance of the L-band lumped direct conversion receiver structure was measured under the conditions of 1.69 GHz frequency for LO-CW signal and RF-QPSK signal, which are input signals for the lumped six-port phase correlator element. The direct conversion receiving structure using the proposed lumped six-port phase correlator element can recovered the good digital I/Q signal.

Design and Implementation of Economical Security Monitoring System (경제적인 보안 모니터링 시스템 설계 및 구현)

  • Ryu, Seok-Ki;Lee, Sun-Heum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1101-1107
    • /
    • 2010
  • DVR is widely used in the security monitoring system because it has excellent performance compared with VCR. In this paper, the new DVR interfaces and repeaters enhancing the performance of the existing DVR have been designed and implemented, which enables a large-scaled security monitoring system to be built economically. A repeater in this paper connects 8 monitoring terminals to 2 channels of DVR and a DVR interface manages 16 repeaters to be able to accommodate 128 monitoring terminals. Eventually, the implemented system has a quadruple scalability compared to the existing systems and can reduce the installation cost substantially by using cost-effective UTP cables instead of coaxial cables. And the system could be effectively used in various environments and conditions because various functions such as video transmission, audio communication, emergency call, and RFID card are integrated into the system.

Implementation of TFDR system with PXI type instruments for detection and estimation of the fault on the coaxial cable (동축 케이블의 결함 측정에 있어서 PXI 타입의 계측기를 이용한 개선된 TFDR 시스템의 구현)

  • Choe, Deok-Seon;Park, Jin-Bae;Yun, Tae-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.91-94
    • /
    • 2003
  • In this paper, we achieve implementation of a Time-Frequency Domain Reflectometry(TFDR) system through comparatively low performance(100MS/s) PCI extensions for Instrumentation(PXI). The TFDR is the general methodology of Time Domain Reflectometry(TDR) and Frequency Domain Reflectometry(FDR). This methodology is robust in Gaussian noises, because the fixed frequency bandwidth is used. Moreover, the methodology can get more information of the fault by using the normalized time-frequency cross correlation function. The Arbitrary Waveform Generator(AWG) module generates the input signal, and the digital oscilloscope module acquires the input and reflected signals, while PXI controller module performs the control of the total PXI modules and execution of the main algorithm. The maximum range of measurement and the blind spot are calculated according ta variations of time duration and frequency bandwidth. On the basis of above calculations, the algorithm and the design of input signals used in the TFDR system are verified by real experiments. The correlation function is added to the TDR methodology for reduction of the blind spot in the TFDR system.

  • PDF

A Design of HD-SDI Camera System for HDcctv Standard Certification (HDcctv 표준 인증을 충족하는 HD-SDI 영상카메라의 설계)

  • Han, Byung-Wan;Lim, Sung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2743-2750
    • /
    • 2012
  • The SDI technology can transmit video, audio and control data with a coaxial cable. The compatibility of HD-SDI Camera is very important. The SDI devices and products without compliance problem are able to guarantee interaction. The HDcctv Alliance has released the standard by classifying the attributes of the SDI devices and products. It is important for each SDI devices and products to keep the compatibility of this standard. In this paper, the camera system that comply with the HDcctv Standard was implemented. In order to receive certification of HDcctv Alliance, the experiment was performed and the satisfied result was gained.

Application of Time Domain Reflectometry to the Monitoring or Rock Mass Deformation with Coaxial Cable (동축 케이블을 이용한 시간영역 반사법의 암반변위 계측에의 적용)

  • 정슬람;정소걸;정현기;박철환;박철환;이희근
    • Tunnel and Underground Space
    • /
    • v.6 no.4
    • /
    • pp.306-315
    • /
    • 1996
  • This paper presents an application of the TDR(Time Domain Reflectometry) to the monitoring of the deformation of rock mass with grouted coaxial cables through laboratory tests. The grouted cable can easily deform together with the rock mass movements, and the deformed cable loses its original capacitance and the reflected waveform produced along the deformed cable consequently represents a change of voltage pulse. Therefore, it is possible to monitor the deformation of rock mass by measuring the changes in these reflection signatures. Shear test of the cemented mortar containing a specimen of coaxial cable showed that the shear deformation correlated linearly with the reflection coefficient, so the TDR was effective to monitor the displacement of the rock mass. Bending test were carried out in order to determine the influence of the crooked cables on the monitoring of rock mass movements. Controlled cirmping and shearing test upon a cable of 50 m long, 12.7 mm diameter showed not only the fact that the reflection amplitudes decreased as the cable length increased but also the proper crimping depth, width and interval between two adjacent crimps. Two coaxial cables-one 100 m long and other 175m long-were installed and grouted into the separate boreholes drilled in a sedimentary formation. The behavior of the cable was monitored with metallic TDR cable tester to measure rock mass deformation based on the interpretative techniques developed through laboratory tests.

  • PDF