• Title/Summary/Keyword: 동축케이블

Search Result 102, Processing Time 0.034 seconds

Shielding Effect Analysis of Communication Cables Using EN50289 for Transfer Impedance Measurement of Coaxial Cable (EN50289 동축케이블 전달 임피던스 측정 방법을 이용한 통신 케이블의 차폐 효과 분석)

  • Lee, Keunbong;Zhang, Nan;Jeon, Jiwoon;Song, Seungje;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1156-1163
    • /
    • 2014
  • In this work by measuring transfer impedance of communication cables using EN50289 its Shielding effect is analyzed. transfer impedance measurement triaxial method using EN50289 is defined in CENELEC, it is unlike triaxial method prescribed in IEC Standard 96-1, can be measured regardless of diameter of coaxial cable and outer conductor. in this paper, transfer impedance measurement device of coaxial cable is designed and made according to EN50289 standard, The analysis determines the reliable working frequency range of coaxial cable and examined the impact of different shielding methods on coaxial cable. The transfer impedance measurements show considerable variations in results with various shielding methods. also the measurement procedure is verified through comparison of calculated and measured transfer impedance of RG-58 cable.

Electromagnetic Field Characteristics of the Slotted Coaxial Clables (동축 슬롯케이블의 전자파 특성)

  • 이애경;김두경;김정기
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.4
    • /
    • pp.17-25
    • /
    • 1991
  • Slotted coaxial cables are used for a wide variety of radio communications and control applications within buildings, subways, tunnels and outdoors. They function as continuous antennas to solve RF coverage problems in difficult or confined areas. In this paper the electric and magnetic field distributions inside and outside of axially slotted coaxial cables are analyzed numerically. This paper gets the fields from the equivalent potentials which are obtained by grid relaxation method. The slot electric field configurations are consistent with Essam E. Hassan's results. The field distributions in the slotted coaxial cables show that the TEM mode doesn't propagate any longer in them. But the fields don't variate with the frequencies that are under the first higher order mode cutoff frequency of shielded coaxial cable of the same dimension The fields inside of the tunnel ($3\times4$) including the slotted coaxial cable axially are similar to those of $TE_{10}$ mode at 38.75 MHz. This method offers the basis for theoretical analysis of coaxial cables with nonuniform slots as well as coaxial cables in tunnels and buildings.

  • PDF

Analysis of the Coupler Using Two Coaxial Cable (두 개의 동축케이블을 이용한 결합기의 연구)

  • 김수현;신철재
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.147-151
    • /
    • 2001
  • 본 논문에서는 두 동축케이블을 사용한 고주파용 결합기 설계 시 결합폭, 외경과 내경의 비 그리고 결합길이의 변수 변화에 따른 특성을 나타내었다. 또한 두 개의 동축케이블 사이에 금속봉을 삽입하여 고주파 대역에서 결합도가 향상된 새로운 구조를 제안하였다. 본 논문에서 제시한 구조는 일반적인 구조에 비하여 지향성과 반사손실 특성을 유지시키면서 결합도가 약1.8 dH 향상되었다.

  • PDF

Modelling and Transient Analysis of a 3-Phase Multi-Layer HTS Coaxial Cable using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 3 상 다층 고온 초전도 케이블의 모델링 및 과도 해석)

  • Lee, Jun-Yeop;Lee, Seok-Ju;Park, Minwon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.1
    • /
    • pp.25-30
    • /
    • 2020
  • Three-phase multi-layer high temperature superconducting coaxial (TPMHTSC) cable is being actively studied due to advantages such as the reduction of the amount of superconducting wire usage and the miniaturization of the cable. The electrical characteristics of TPMHTSC cables differ from those of conventional superconducting cables, so sufficient analysis is required to apply them to the actual system. In this paper, the authors modeled 22.9 kV, 60 MVA TPMHTSC cable and analyzed the transient characteristics using a PSCAD/EMTDC-based simulation. As a result, when a fault current flows in TPMHTSC cable, most of the fault current is bypassed through the copper former layers. At this time, the total cable temperature increased by about 5 K. Through this study, we can verify the reliability of the TPMHTSC cable against the transient state, and it can be helpful for the practical application of the cable in the future.

Analysis of HEMP Coupling Signal for a Coaxial Cable with Braided Shields (Braided Shield를 가진 동축 케이블의 HEMP 결합 신호 해석)

  • Lee, Jin-Ho;Cho, Jea-Hoon;Kim, Eung-Jo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.790-796
    • /
    • 2011
  • The system which is exposed in the impact range of High-altitude Electromagnetic Pulse(HEMP) may get serious damage because HEMP has a very large electric field value, a very fast rise-time, and so on. Electromagnetic analysis should be performed for signals coupled to the opening or cables of the system prior to derive the system design specifications in order to protect the system against HEMP adequately. In this paper, we analyzed the HEMP coupled signals for the coaxial cable which is generally used to transmit and receive video or RF signals and compared the coupled signal of the one wire with that of the inner conductor of a coaxial cable to confirm the decreased effect of HEMP by the shield. The coaxial cable is analyzed by the external and internal region of the shield separately. For the external region of the coaxial cable, general scattered equation was applied to calculate currents on the surface of the shield and for internal region of the coaxial cable, chain matrix algorithm is used. To verify this paper the analyzed results were compared the results of the existing paper and the two results have good agreements.

Serial interface system of HDTV signal in coaxial cable (동축케이블을 이용한 HDTV 신호의 serial 전송 방식)

  • 이호웅;이문기;강철호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.3
    • /
    • pp.622-628
    • /
    • 1996
  • This paper describes a new serial interface system which uses conventional 75 ohm coaxial cable. Typically parallel 25 pin cable and connectors are used to transfer and receive the data between digital systems such as HDVCR, D3 VTR and HDTV Receiver. The coaxial cable is more desirable for consumer product applications and also for studio applications where long signal paths and switching are required. This serial data transfer technique is thoroughly tested and utilied in the data transmission/reception between systems more than 200 feet apart. It is also cost effective because it does not require RF PLL, SCRAMBLING, and NRZI hardware.

  • PDF

A Study on Shield Wire Stripping of Micro Coaxial Cable for Medical Device Using Nd:YAG Laser (Nd:YAG 레이저를 이용한 의료기기용 마이크로 동축케이블의 실드선 탈피에 관한 연구)

  • Lee, Jeong-Wan;Kim, Jung-Hoon
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.35-41
    • /
    • 2006
  • Recently, as ultrasonic medical devices are gradually developed, many of those requires smaller and more precision coaxial cables in probe. So, the use of micro coaxial cable becomes an efficient solution for ultrasonic machine. However, there are many difficulties in stripping micro coaxial cable by traditional mechanical process. In this paper, we use the Nd-YAG laser for the efficient stripping of conduct wire of cable. We propose a new method to strip the shield wire of micro coaxial cable. Through some experiments, we found that there is a new possibility in the proposed method. Also, in order to enhance the performance, we propose a preprocess of the cable before stripping.

  • PDF

Shield Wire Stripping of Micro Coaxial Cable for Medical Device Using Laser (레이저를 이용한 의료기기용 미세 동축케이블의 실드선 탈피)

  • Lee, Jeong-Wan;Kim, Jung-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.9
    • /
    • pp.64-71
    • /
    • 2009
  • Recently as ultrasonic medical devices are gradually developed, many of those require smaller and more precision coaxial cables in the probe. So, the use of micro coaxial cable becomes an efficient solution for ultrasonic machine. However, there are many difficulties in stripping micro coaxial cable by traditional mechanical process. In this paper we use the Nd:YAG laser for the efficient striping of conduct wire of cable. Through some experiments, we found that there is a new possibility in the proposed method. Also, we propose a pre-process of the cable before stripping in order to enhance the performance.

Time-Frequency Domain Reflectometry based on Real-Time Spectrum Estimation for Detection and Localization of a Fault on a Coaxial Cable (실시간 스펙트럼 추정기에 기반한 시간-주파수 영역에서의 동축케이블 결함 검출 기법)

  • Doo, Seung-Ho;Ra, Won-Sang;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.300-301
    • /
    • 2007
  • 본 논문에서는 실시간 스펙트럼 추정기에 기반하여 시간-주파수 영역 반사파 계측 시스템에서의 동축케이블 결함을 검출하는 방법을 제안한다. 시간-주파수 영역 반사파 계측 시스템은 가우시안 포락선(Gaussian Envelop)모양의 첩 신호를 기준신호로 하여 도선에 반사파를 분석하는 기법으로써 타 방법에 비하여 높은 정확도를 자랑하는 것으로 알려져 있다. 하지만 결함 위치를 추정하기 위해 Wigner 시간 주파수 분포 함수를 이용하므로 계산량 증가에 따른 실시간 구현이 어렵다는 단점이 있었다. 이러한 단점을 극복하기 위하여 본 논문에서는 LMS 스펙트럼 추정기를 이용한 시간-주파수 영역 반사파 계측 시스템의 구현방법을 새롭게 제안한다. 제안된 기법은 실제 동축케이블에 대한 실험결과를 통하여 그 성능을 입증하도록 한다.

  • PDF

건축물에서의 SPD와 최신 기술

  • 김언석;이기홍
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.8-23
    • /
    • 2004
  • 정보화 시대로 접어들면서 빌딩은 전자화 가전기기나 전기설비들이 많이 설치되고 있다. 통신 시스템의 발달 및 보안, 방재 시스템의 발달로 빌딩들은 통신이나 신호 케이블들이 설치되어 있다. 이들 건축물과 외부의 통신회사들과도 동축케이블 등으로 연결되어 있다. 낙뢰나 과도서지가 전원 및 통신케이블을 타고 빌딩 내부로 유입되어 전자기기나 통신기기들을 파괴시키거나 오동작하는 사례가 많다. 독일의 경우 도심 빌딩에 낙뢰가 떨어진 경우 반경 3〔km〕 떨어진 건물에서 피해가 발생된 것으로 보고되고 있다. (중략)

  • PDF