• Title/Summary/Keyword: 동적 지하구조

Search Result 82, Processing Time 0.023 seconds

3-Dimentional numerical study on dynamic behavior of connection between vertical shaft and tunnel under earthquake loading (3차원 수치해석을 이용한 지진 시 수직구-터널 접속부 동적 거동 분석)

  • Kim, Jung-Tae;Cho, Gye-Chun;Kang, Seok-Jun;Kim, Ki Jung;Hong, Eun-Soo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.887-897
    • /
    • 2018
  • 3D time history analysis was performed on vertical shaft-tunnel connection to provide insight into the dynamic stress-strain behavior of the connection considering the effects of soil layers, periodic characteristics and wave direction of earthquakes. MIDAS GTS NX based on FEM (Finite Element Method) was used for this study. From this study, it is revealed that the maximum displacement occurred at the upper part of the connection when the long period seismic waves propagate through the tunnel direction in soft ground. Also, stress concentration occurs due to different behaviors of vertical shaft and tunnel, and the stress concentration could be influence for safety on the connection. The results of this study could be useful for the seismic performance design of vertical shaft-tunnel connection.

Dynamic Response of Underground Openings Considering the Effect of Water Saturation (지하수의 영향을 고려한 지하공동구조체의 동적응답)

  • 김선훈;김광진
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.281-288
    • /
    • 2000
  • Three-dimensional dynamic analysis of underground openings subjected to explosive loadings considering the effects of water saturation is carried out in this study. The problem considered in this study is an unlined circular tunnel subjected to a finite cylindrical charge placed at the center of the proposed tunnel. The surrounding rock mass is assumed to be the limestone with 13.5% of porosity. Two calculations are compared using an identical explosive charge; the first in dry rock of 13.5% porosity, the second in the identical rock, but in a fully saturated condition. It is shown that underground openings in saturated porous medium could be significantly more vulnerable to the potential damages associated with high motions and shear failure than those in dry medium.

  • PDF

Sensitivity Analysis Study of Geotechnical Factors for Gas Explosion Vibration in Shallow-depth Underground Hydrogen Storage Facility (저심도 지하 수소저장소에서의 가스 폭발 진동에 대한 지반공학적 인자들의 민감도 분석 연구)

  • Go, Gyu-Hyun;Woo, Hyeon‑Jae;Cao, Van-Hoa;Kim, Hee-Won;Kim, YoungSeok;Choi, Hyun-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.4
    • /
    • pp.169-178
    • /
    • 2024
  • While stable mid- to large-scale underground hydrogen storage infrastructures are needed to meet the rapidly increasing demand for hydrogen energy, evaluating the safety of explosion vibrations in adjacent buildings is becoming important because of gas explosions in underground hydrogen storage facilities. In this study, a numerical analysis of vibration safety effects on nearby building structures was performed assuming a hydrogen gas explosion disaster scenario in a low-depth underground hydrogen storage facility. A parametric study using a meta-model was conducted to predict changes in ground dynamic behavior for each combination of ground properties and to analyze sensitivity to geotechnical influencing factors. Directly above the hydrogen storage facility, the unit weight of the ground had the greatest influence on the change in ground vibration due to the explosion, whereas, farther away from the facility, the sensitivity of dynamic properties was found to be high. In addition, in evaluating the vibration stability of ground building structures based on the predicted ground vibration data and blasting vibration tolerance criteria, in the case of large reinforced concrete building structures, the ground vibration safety was guaranteed with a separation distance of about 10-30 m.

Pore flow Characteristics in Seabed around Dike Due to Variation of Ground Water Level (지하수위 변화에 따른 호안 주변 지반내의 흐름특성)

  • Kim, Chang-Hoon;Kim, Do-Sam;Hur, Dong-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.5
    • /
    • pp.408-417
    • /
    • 2007
  • Recently, an artificial beach has been constructed compensating for loss of the natural one caused by the development of coastal area, as well as serving as a location for recreational activities such as sea bathing. It is well known that some structure should be constructed to protect an artificial beach from the outflow due to wave action of the reclaimed sand. In general, dike is utilized as the structure to protect an artificial beach. And, one of the factors which may need to be taken into consideration for stability of dike on seabed foundation is the ground water behavior behind dike. However, the interrelated phenomena of nonlinear wave and ground water response have relatively little attention although these interactions are important for stability of structure and sand suction to the artificial beach. In this paper, the numerical wave tank was developed to clarify nonlinear wave, dike and ground water dynamic interaction, which can simulate the difference of ground water and mean water level. Using the developed numerical wave tank, the present study investigates how variation of ground water level influences hydrodynamic characteristics in seabed around dike and numerically simulates the wave fields, pore flow patterns, pore water pressures and vorticities according to variation of ground water level. Numerical results explain well how hydrodynamic characteristics in seabed around dike is affected by the variation of ground water level.

Seismic Response Analysis Method for 2-D Linear Soil-Structure Systemsusing Finite and Infinite Elements (유한요소와 무한요소를 사용한 2차원 선형 지반-구조물계의 지진응답해석법)

  • 김재민;윤정방;김두기
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.2
    • /
    • pp.231-244
    • /
    • 2000
  • This paper presents a dynamic analysis technique for a 2-D soil-structure interaction problem in the frequency domain, which can directly be applied as an analysis tool for seismic response analyses of underground structures, tunnels, embankments, and so on. In this method, the structure and near-field soil is modeled by the standard finite elements, while the unbounded far-field soil is represented using the dynamic infinite elements in the frequency domain. The earthquake-input motion is regarded as traveling P and SV waves which are incident vertically from the far-field of underlying half-space to the near-field of layered medium. The equivalent earthquake forces are then calculated utilizing so-called fixed-exterior-boundary-method and the free-field responses including displacements and tractions. For the verification of the present study, seismic response analyses are carried out for a multi-layered half-space free-field soil medium and a cylindrical cavity embedded in a homogeneous half-space. Comparisons of the present results with solutions by other approaches indicate that the proposed methodology gives accurate estimates. Finally, an application example of seismic response analysis for a subway station is presented, which demonstrates the applicability of the present study.

  • PDF

A Study on the Blasting Dynamic Analysis Using Superposition Modeling Data (중첩모델링자료를 활용한 발파 동해석 기법에 관한 연구)

  • Park, Ji-Woo;Kang, Choo-Won;Go, Jin-Seok;Jang, Ho-Min
    • Tunnel and Underground Space
    • /
    • v.18 no.4
    • /
    • pp.280-288
    • /
    • 2008
  • Since blast-induced vibration may cause serious problem to the rock mass as well as the nearby structures, the prediction of blast-induced vibration and the stability evaluation must be performed before blasting activities. Dynamic analysis using measurement vibration waveform which is measured by bore hole blasting or test blasting has been increased recently in order to analyze the effect of the blast-induced vibration. The waveform made by bore hole blasting has the similar vibration level and duration to those the waveform of sing hole has. However, there can be a little difference in attenuation characteristics with the blast induced vibration waveform in the field. Through the superposition modeling of single hole waveform, I obtained the vibration waveform on the blasting condition changes and conducted dynamic analysis using this waveform in this study.

Ground Vibration Reduction Technology Using High Damping Polymer Concrete (고 감쇠 폴리머 콘크리트를 활용한 지반진동 저감기술에 대한 연구)

  • Kim, Jeong-Jin;Seok, Won-Gyun;We, Joon-Woo;Ahn, So-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.154-160
    • /
    • 2021
  • Recently, there have been increasing construction works carried out in urban centers, which are inducing frequent artificial vibration in the vicinity of existing structures due to such construction works. moreover, in case of industrial estates, vibration is induced due to operation of machines in the surrounding areas, thereby causing problems. meanwhile, in case of ordinary concrete that compose structure has low level of damping capability for vibration. accordingly, there are difficulties in blocking a wide range of vibrations delivered to the structures from outside including not only vibrations generated in the structures themselves but also ground vibration. recently, numerous studies are being carried out actively on high-damping system that markedly enhanced the damping performances of structures by utilizing polymer concrete in order to block the vibrations delivered to the structures through ground. therefore, this study compared the performances of polymer concrete with those of ordinary concrete, polyurethane pad and foamed rubber pad in order to review its performances in reducing ground vibration. for this purpose, review of FRF and vibration acceleration as dynamic characteristics was made. after comparative verification on the dynamic characteristics is made when polymer concrete and other aforementioned materials are applied to underground structures, the possibility of application of polymer concrete to structures is reviewed.

3D Transmitting Boundary for Water-Saturated Transversely Isotropic Soil Strata Based on the u-w Formulation (u-w 정식화에 근거한 지하수로 포화된 가로등방성 층상지반에서의 3차원 전달경계)

  • Lee, Jin-Ho;Kim, Jae-Kwan;Ryu, Jeong-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.67-86
    • /
    • 2009
  • In this study, a 3D transmitting boundary in water-saturated transversely isotropic soil strata has been developed based on u-w formulation for application to general 3D analysis. Behavior in the far field region is expanded in the Fourier series, and dynamic stiffness for each term is obtained based on the u-w formulation. Transformation of the dynamic stiffness is presented to combine the transmitting boundary with the 3D finite elements for the near field region formulated in a 3D Cartesian coordinate system. The developed transmitting boundary is verified through a comparison of the dynamic behavior of a rigid circular foundation with the results from the existing numerical method. In addition, the developed transmitting boundary is applied to the analysis of the dynamic behavior of rigid foundations of diverse shapes, and the effects of the level of the groundwater table on the dynamic stiffness of a rigid rectangular foundation in the water-saturated transversely isotropic layered stratum are studied.

The Study on Seismic Analysis Methods for Underground Structures (지중구조물의 내진해석방법에 관한 연구)

  • Jeong, Gwang-Mo;Bang, Myeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.75-84
    • /
    • 2011
  • In this paper various numerical analyses are carried out according to behavior characteristics of structures and types of seismic design methods as a study on the seismic analysis for underground structures. Equivalent Static Force Procedure and Response Displacement Method commonly used in practiral design are adopted and Time History Method regarded as the most accurate analysis method is selected to verify the results of two practical methods above. 3-D modelling for seismic analysis of structures is introduced to consider Structure Soil Interaction and all analyses are based on Korea Structural Concrete Design Code. After numerical analyses, Equivalent Static Force Procedure and Response Displacement Method showed relatively lager values than those of Time History Method, so it is identified that above two methods are suitable for practical design purpose.

  • PDF

Experimental Studies on PSC Airpit-Slab with Fire Resistance Panel under Static and Dynamic Loads (내화패널이 부착된 프리캐스트 PSC 풍도슬래브의 정적/동적하중에 관한 실험연구)

  • Kim, Tae Kyun;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.245-253
    • /
    • 2012
  • In the longway tunnel and underground traffic road, the structure of transverse ventilation system is constructed by the airpit slab. In this study, the full scale specimens of the PSC airpit slab that attached fire resistance panel are performed the static and dynamic loading tests for evaluation of bending capacity. The first of all, it confirmed the evaluations about the fundamental efficiency of the fire resistance panel and PSC slab by the 3-point bending test and pull-off test. The tests are performed for evaluation of the bending resistance under ultimate static load and the bonded capacity under dynamic fatigue load. A fatigue test is performed for an investigation of the effect on wind pressure that is developed by transit of traffic. The damage or debonding on surface between fire resistance panel and PSC slab was not developed in dynamic fatigue load test, also the behavior of the specimens is very stable and the debonding of the fire resistance panel attached at the bottom surface of PSC slab was not developed in static load test, too. Therefore, the crack or debonding of the fire resistance panel will be not developed by external loads during the construction or completion of the precast fire resistance system.