• 제목/요약/키워드: 동시치료

Search Result 1,159, Processing Time 0.024 seconds

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

The Relation between Microsatellite Instability and the Thymidylate Synthase Expression in Gastric Cancer (위암에서 Microsatellite Instability와 Thymidylate Synthase의 상관관계)

  • Ko, Hyun-Seok;Ahn, Chang-Wook;Kang, Hae-Youn;Kim, Kwang-Il;Hong, Sung-Pyo;Ahn, Dae-Ho
    • Journal of Gastric Cancer
    • /
    • v.8 no.4
    • /
    • pp.169-175
    • /
    • 2008
  • Purpose: The main target of 5-fluorouracil (5-FU) is thymidylate synthase (TS). A high TS expression has been identified as promoting resistance to 5-FU. For colorectal cancers, the response to 5-FU based adjuvant chemotherapy is different according to the microsatellite instability (MSI) status. The reports on the relationship between MSI and the TS expression in colorectal cancer have been inconsistent. No data is available for gastric cancer regarding the relationship between MSI and the TS expression. Therefore, we studied the relationship between MSI and the TS expression in gastric cancer. Materials and Methods: Ninety-nine consecutive patients who underwent radical gastrectomy for gastric cancer from January 2004 to May 2006 at Bundang CHA hospital were studied. MSI was assessed for five markers (BAT25, BAT26, D2S123, D5S346, and D17S250) by PCR and with using an ABI prism 3100 Genetic analyzer. The TS expression was analyzed by immunohistochemistry with using mouse anti-thymidylate synthase monoclonal antibody to the TS 106 clone. Results: Out of the ninety-nine patients, MSS/MSI-L was detected in 92 (92.1%) cases and 7 cases (7.1%) were MSI-H. A negative TS expression was found in 46 (46.5%) cases, a low TS expression was found in 33 (33.3%) and a high TS expression was found in 20 (20.2%). Out of 92 MSS/MSI-L patients, the number of patients with negative, low and high TS expressions were 46 (50%), 30 (32.6%) and 16 (17.4%), respectively. Out of the 7 MSI-H patients, the number of patients with negative, low and high TS expressions were 0 (0%), 3 (42.9%) and 4 (57.1%), respectively. The relationship between MSI-H and a high TS expression was statistically significant. Conclusion: Gastric cancer with MSI-H showed higher levels of a TS expression compared to the gastric cancer with MSS/MSI-L.

  • PDF

Epidermal Changes of the Adhesive Disks During Wall Attachment in Parthenocissus tricuspidata (착생에 따른 담쟁이덩굴 흡착근 표피조직의 변화)

  • Kim, Jung-Ha;Kim, In-Sun
    • Applied Microscopy
    • /
    • v.37 no.2
    • /
    • pp.83-91
    • /
    • 2007
  • The present study examined the epidermal changes of adhesive disks which occur during attachment in Parthenocissus tricuspidata using scanning and transmission electron microscopy. Several adhesive disks, each covered with a bract, develop from the shoot apical meristem during early development. In the initial stage, the adhesive disks are club-shaped and their upper and lower epidermis are indistinguishable. However, in the actively growing stage, they become spherical and both epidermis are clearly differentiated into the adventitious roots. Prior to wall attachment, the adhesive disks exhibit adaxial convex and abaxial concave shapes, and electron-dense substances are abundant in the vacuoles of epidermal cells. The peripheral area of the adhesive disk is adhered first to the wall surface, while the central area is drawn inward in a vacuum-like state during attachment. As the attachment progresses and the electron-dense substances continue to discharge, the upper and lower epidermis rapidly undergo deterioration and the disks shrink considerably. At this stage, structural changes of the lower epidermis occur much faster than in the upper one. The discharged substance is accumulated on the wall surface, and this aids the attachment of adhesive disks on the wall for long periods. In this manner, the shape and structure of the adhesive disk epidermis change drastically from initial growth to the mature stage. Further, the role of electron-dense substance and shrinkage of the disk during attachment has been discussed in Parthenocissus tricuspidata.

Expression of Growth Factors and Secretory Leukocyte Protease Inhibitor (SLPI) in RAW264.7 Cells after Lipopolysaccharide (LPS) Stimulation (대식세포주 (RAW264.7)에서 박테리아성 지질다당류 (LPS) 자극에 의한 분비백혈구단백분해효소억제제 (SLPI)와 성장인자들의 발현)

  • Son, Wook-Hee;Choi, Baik-Dong;Jeong, Soon-Jeong;Wang, Guan-Lin;Hwang, Ho-Keel;Jeong, Moon-Jin
    • Applied Microscopy
    • /
    • v.37 no.2
    • /
    • pp.93-102
    • /
    • 2007
  • Secretory leukocyte protease inhibitor (SLPI) was known as one of bacterial lipopolysaccharide (LPS)-induced products of macrophage. Macrophages play an important role in the development of inflammatory responses by secreting an array of cytokines and chemokines in a tissue microenvironment. To identify the function and relationship between potent growth factors and SLPI after LPS stimulation, we conducted reverse transcriptase polymerase chain reaction (RT-PCR) and Western blots for the detection of mRNA and protein expression of SLPI and growth factors such as VEGF, PDGF, bFGF after 100 ng LPS stimulation on the RAW264.7 cells. The result of RT-PCR was showed SLPI mRNA expression was increased from 60 min to 48h in RAW 264.7 cells after incubation with LPS. VEGF and PDGF mRNA was expressed highly at initial stage by LPS stimulation. The mRNA of bFGF and type I collagen was very weakly expressed after LPS stimulation. SLPI protein level was increased likely the mRNA levels in RAW 267.7 cells. Additionally, phase contrast and scanning electron microscopic observation demonstrated that the LPS induce the change of morphology of the RAW264.7 cells. From these results, it suggest that expression of SLPI by LPS treatment may associate with VEGF and PDGF expression in RAW264.7 cells.

Expression of Cell Cycle Related Genes in HL60 Cells Undergoing Apoptosis by X-irradiation (HL60 세포주에서 방사선 조사에 의한 Apoptosis와 세포 주기 관련 유전자의 발현 변화)

  • Kim, Jin-Hee;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.377-388
    • /
    • 1998
  • Purpose : To evaluate changes in expression of cell cycle related genes during apoptosis induced in HL60 cells by X-irradiation to understand molecular biologic aspects in mechanism of radiation therapy. Material and Methods : HL-60 cell line (promyelocytic leukemia cell line) was grown in culture media and irradiated with 8 Gr by linear accelerator (6 MV X-ray). At various times after irradiation, ranging from 3 to 48 hours were analyzed apoptotic DNA fragmentation assay for apoptosis and by western blot analysis and semi-quantitative RT-PCR for expression of cell cycle related genes (cyclin A, cyclin B, cyclin C, cyclin Dl, cyclin E, cdc2, CDK2, CDK4, $p16^{INK4a}$, $p21^{WAF1}$, $p27^{KIP1}$, E2F, PCNA and Rb). Results : X-irradiation (8 Gy) induced apoptosis in HL-60 cell line. Cycline A protein increased after reaching its peak 48 h after radiation delivery and cyclin E, E2F, CDK2 and RB protein increased then decreased after radiation. Radiation induced up-regulation of the expression of E2F is due to mostly increase of Phosphorylated retinoblastoma proteins (ppRb). Cyclin Dl, PCNA, CDC2, CDK4 and $p16^{INK4a}$ protein underwent no significant change at any times after irradiation. There was not detected $p21^{WAF1}$ and $p27^{KIP1}$ protein. Cyclin A, B, C mRNA decreased immediately after radiation and then increased at 12 h after radiation. Cyclin Dl mRNA increased immediately and then decreased at 48 h after radiation. After radiation, cyclin E mRNA decreased with the lapse of time. CDK2 mRNA decreased at 3h and increased at eh after radiation. CDK4 mRNA rapidly increased at 6 to 12 h after radiation. There was no change of expression of $p16^{INK4a}$ and not detected in expressin of $p21^{WAF1}$ and $p27^{KIP1}$ mRNA. Conclusion : We suggest that entry into S phase may contribute to apoptosis of HL60 cells induced by irradiation. Increase of ppRb and decrease of pRb protein are related with radiation induced auoptosis of HL60 cells and tosis of HL60 cells induced by irradiation. Increase of ppRb and decrease of PRb protein are related with radiation induced apoptosis of HL60 cells and this may be associated with induction of E2F and cyclinE/CDK2. These results support that $p21^{WAF1}$ and $p27^{KIP1}$ are not related with radiation induced-apoptosis.

  • PDF

Preparation and Animal Imaging of $^{153}Sm$-EDTMP as a Bone Seeking Radiopharmaceutical (골친화성 방사성의약품 $^{153}Sm$-EDTMP의 합성과 동물영상)

  • Choi, Tae-Hyun;Kim, Se-Jung;Shin, Byung-Chul;Woo, Kwang-Sun;Chung, Wee-Sup;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.44-48
    • /
    • 2005
  • Purpose: Ethylenediamine-tetramethylenephosphonic acid (EDTMP) has widely used chelator for the labeling of bone seeking radiopharmaceuticals complexed with radiometals. $^{153}Sm$ can be produced by the HANARO reactor at the Korea Atomic Energy Research Institute, Taejon, Korea. $^{153}Sm$ has favourable radiation characteristics $T1/2=46.7\;h,\;{\beta}_{max}=0.81\;MeV\;(20%),\;0.71\;MeV\;(49%),\;0.64\;MeV\;(30%)\;and\;{\gamma}=103\;keV\;(30%)$ emission which is suitable for imaging purposes during therapy. We investigated the labeling condition of $^{153}Sm$-EDTMP and imaging of $^{153}Sm$-EDTMP in normal rats. Materials and methods: EDTMP 20 mg was solved in 0.1 mL 2 M NaOH. $^{153}SmCl^3$ was added to EDTMP solution and pH of the reaction mixtures was adjusted to 3 and 12, respectively. Radiochemical purity was determined with paper chromatography. After 30 min. reaction, reaction mixtures were neutralized to pH 7.4, and the stability was estimated upto 120 hrs. Imaging studies of each reaction were perfomed in normal rats (37 MBq/0.1 mL). Results: The labeling yield of $^{153}Sm$-EDTMP was 99%. The stability of pH 8 reaction at 60, 96 and 120 hr was 99%, 95%, 89% and that of pH 12 at 36, 60, 96 and 120 hr was 99%, 95%, 88%, 66%, respectively. The $^{153}Sm$-EDTMP showed constantly higher bone uptake from 2 to 48 hr after injection. Conclusion: $^{153}Sm$-EDTMP, labeled at pH 8 reaction condition, has been stably maintained. Image of $^{153}Sm$-EDTMP at 2, 24, 48 hr after injection, demonstrate that $^{153}Sm$-EDTMP is a good bone seeking radiopharmaceuticals.

Assessment of Growth Conditions and Maintenance of Law-Protected Trees in Je-cheon City (제천시 보호수의 생육환경 및 관리현황 평가)

  • Yoon, Young-Han;Ju, Jin-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • Law-protected trees are our precious asset as natural resources with history and tradition and natural heritage which should be protected and maintained well to bequeath next generation. Law-protected trees have not only thremmatologic and genetic meaning but also environmental and emotional meaning for their value to be high. This study investigated location, vitality, wrapping condition of root area and status of maintenance of the trees to figure out their growth environment and status of maintenance in a small-middle city through survey on those of law-protected trees in Je-cheon. There showed 300 more year old trees in Je-cheon mostly and the number of trees located in flat fields was the highest. For location type, village, hill and road types were presented in the order and for degree of development, land for building was found most frequently. The average electric resistance of the formative layer was measured to be $8.4k{\Omega}$ and four trees showed bark separation. Most law-protected trees underwent tree surgery, and complete bareness of root area was observed in a tree. The root area of two trees was covered with concrete. pH of soil was recorded to be 5.0~8.4 with its average of 7.1 and electric conductivity(EC) was less than 0.5 dS/m. For status of maintenance rearing facilities were placed for 16 trees out of totally 48 ones and stone fence was done for three ones. Tree surgery was conducted for 33 trees to prevent and to treat decomposed parts of holes. Direction boards were installed for 23 trees. Based on these results, measures to manage systematically law-protected trees in Jecheon could be suggested as follows. First, a sufficient space for growth of low part of trees should be secured. Second, a voluntary management should be induced by advertising them to residents in a community. Third, rearing facilities and direction boards of law-protected trees should be placed and related education should be conducted. Fourth, through operation of the department for law-protected trees consisting of related professions and cooperation among related departments the trees should be maintained continuously.

Quality Characteristics and Inhibition Activity against Helicobacter pylori KCCM 40449 of Liquorice Yogurts Manufactured by Exopolysaccharide Producing Lactic Acid Bacteria (Exopolysaccharide 생성 유산균을 이용한 감초 추출물 첨가 Yoghurt의 품질특성 및 Helicobacter pylori KCCM 40449 억제활성)

  • Jung, Seung-Won;Kim, Cheol Woo;Lee, Su Han
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.346-354
    • /
    • 2011
  • This study was carried out to fortify the antimicrobial activity of yoghurt by adding liquorice extract to it. The liquorice extracts (1 mg/mL) showed relatively high antibacterial activity against H. pylori KCCM 40449 (p < 0.05). The solvent liquorice extracts of minimal inhibitory concentrations (MIC) against H. pylori KCCM 40449 were 25- 100 ${\mu}g$/mL. Lactobacillus amylovorus DU-21 with high EPS production ability were inoulated to milk after the addition of different amounts of liquorice extracts (0.0%, 0.05%, 0.1% and 0.2%). The physico-chemical characteristics of yoghurts added with liquorice extracts were examined. The initial pH, titratable acidity, viscosity and viable cell counts of the yoghurt added liquorice extracts were 3.41-3.51, 1.021-1.091%, 1,686-1,930 cp and 9.41-9.38 Log CFU/mL, respectively. The viscosity and syneresis of yoghurt were better than that of the control. Antimicrobial activity against H. pylori KCCM 40449 increased with increasing addition of liquorice extract. However, the sensory score of yoghurt added with different amounts of liquorice extracts was lower than that of the control (p < 0.05). As a result of the sensory evaluations, the flavor, taste, texture, color and overall acceptability of the yoghurt with 0.05% liquorice extract were found to be much better than those of the other groups (p < 0.05). Overall, the optimal amount of liquorice extract added in the manufacture of yoghurt was 0.05% of the total weight. Further studies on increment of antimicrobial activity and palatability of liquorice extract added yoghurt are necessary.

A survey of the Necessity and Perceptions of Character Education of Health Science and Non-health Science University Students (일개 보건계열 및 비보건계열 학생들의 인성교육에 대한 필요성 및 인식도 조사)

  • Choi, Yong-Keum;Oh, Tae-Jin;Lee, Hyun;Lim, Kun-Ok;Hong, Ji-Heon;Kim, Eun-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.344-351
    • /
    • 2019
  • The purpose of this study was to obtain the basic data for developing more advanced courses on character education by surveying and analyzing the perception and demands of character education of university students and further, to provide useful information for creating institutional protocol on character education. The study was conducted from April 2018 to May 2018 on students attending the departments of non-health science and health science university students. A total of 206 students participated in this study, and all the students in the non-health science and health science departments were found to be highly aware of the need for character education, its importance and the possibility of personality development through learning. Students from all the departments showed high levels on average in terms of self-understanding according to their personality abilities, and especially their high levels of 'consideration' and 'responsibility'. For the differences in perception of self-efficacy, the lowest level of recognition was for 'will' and the average values were not high. In their response to personality level, all students answered that their personality was 'high' (42.1%), and that the personality education courses at the schools they are currently attending were 'not satisfied' with both the non-health science and health science students. As a result, there were higher results overall for the health science students than that for the non-health science students, but there were not many significant differences. To this end, education institutes will have to prepare conditions for university students to cultivate their expertise in character, while at the same time helping them grow into human beings with the qualities demanded by society. In addition, the government should establish curriculums and content by accurately identifying the needs of character education and devising concrete measures for their implementation, and by more faithfully considering quantitative and qualitative context types for the content base of character education.

Questionnaire survey for the clinical trial participants who experienced both digital and conventional impression (디지털 인상법과 종래인상법을 동시에 경험한 임상시험자를 대상으로 한 설문지분석)

  • Yang, Eunbee;Kim, Bongju;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.270-279
    • /
    • 2018
  • Purpose: The aim of this study was to assess the patients' perception, acceptance, and preference of the difference between a conventional impression and digital impression through questionnaire survey. Materials and Methods: Thirteen (6 male, 7 female) subjects who experienced both digital and conventional impression at the same day were enrolled in this study. Conventional impression were taken with polyvinylsiloxane and digital impression were performed using a newly developed intra-oral scanner. Immediately after the two impressions were made, a survey was conducted with the standardized questionnaires consisting of the following three categories; 1) general dental treatment 2) satisfaction of conventional impression 3) satisfaction of digital impression. The perceived source of satisfaction was evaluated using Likert scale. The distribution of the answers was assessed by percentages and statistical analyses were performed with the paired t-test, and P < 0.05 was considered significant. Results: There were significant differences of the overall satisfaction between two impression methods (P < 0.05). Digital impression showed high satisfaction in less shortness of breath and odor to participants compared to conventional impression. The use of an oral scanner resulted in a discomfort of TMJ due to prolonged mouth opening and in lower score of the scanner tip size. Conclusion: It was confirmed that the preference for the digital impression using intraoral scanner is higher than the conventional impression. Most survey participants said they would recommend the digital impression to others and said they preferred it for future prosthetic treatment.