• Title/Summary/Keyword: 동시촬영

Search Result 392, Processing Time 0.031 seconds

Implementation of multi-touching and application based touch interface using Infrared (적외선을 이용한 멀티 터치와 터치 인터페이스의 구현)

  • Yoo, Ki-Sun;Hong, Rok-Ji;Moon, Il-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.928-934
    • /
    • 2010
  • In this paper, the method introduce for touching signals and run the application on the multi touch environment using infrared light. When the user touches the screen, the infrared camera make a movie the light and the light which made through image processing communicate from TUIO(Tangble User Interface Object) protocol to Application. this Program is using the delivery informations which are occurred the event to Application. The Application which use the touch can exchange the Andoroid Phone between Mobile picture supervision Application also this equipment introduces about the musical entertainment Application which play a music many users at the same time.

Violence detector using both CCTV videos and extracted skeleton images (CCTV 원본 영상과 추출된 스켈레톤 영상을 함께 이용하는 폭력 인식기)

  • Joo, Hyun-Seong;Kim, Yoo-Sung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.838-841
    • /
    • 2020
  • 본 논문은 영상 속 폭력행위를 인식하기 위해 3 차원 컨벌루션을 활용하여 원본 영상과 스켈레톤(skeleton)영상으로부터 추출한 시각 및 움직임 정보를 동시에 활용하는 2-스트림 구조의 폭력상황 인식기를 제안한다. 제안된 폭력상황 인식기에서는 수평, 수직 방향의 큰 움직임이 많이 나타나는 폭력영상의 특성을 활용하기위해 각 방향의 특성을 독립적으로 학습할 수 있는 split-FAST 3차원 컨벌루션을 활용하고, 3 차원 Attention 을 적용하여 시각 및 움직임 정보 추출 시 영상의 중요지역을 중점적으로 반영하도록 함으로써 촬영 기기의 이동 또는 여러 사람의 뒤엉킴 등으로 영상의 시점 변화나 상황 변화가 잦은 경우에도 강인한 성능을 가질 수 있도록 하였다. 또한 기존의 연구들과 달리 비제약적인 환경에서 CCTV, 모바일 카메라 등으로 촬영된 실제 영상들로 구성된 RLVS 데이터셋을 학습 데이터로 사용함으로써 실제의 폭력 행위를 잘 인식할 수 있도록 하였다. RLVS 를 이용한 평가 실험에서 제안된 폭력상황 인식기가 약 92%의 인식 정확도를 얻었다.

Capturing system for wide viewing hologram generation (광시야각 홀로그램 합성을 위한 촬영 시스템)

  • Kim, Youngrok;Sung, Hyunsik;Hong, Keehoon;Choi, kihong;Min, Sung-Wook
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.07a
    • /
    • pp.561-562
    • /
    • 2020
  • 기하학적 위상렌즈를 활용한 광시야각 홀로그램 합성을 위한 시스템을 제안하고 설계하여 제작하였다. 광시야각 홀로그램은 실시간 홀로그램 영상을 녹화하는 과정에서 동시에 물체의 다른 파면을 기록할 수 있기 때문에 물체의 3 차원 정보를 일련의 알고리즘을 통해 데이터화 시키는 과정을 가능하게 한다. 본 논문에서는 기하학적 위상렌즈와 편광 이미지 센서를 결합해 비간섭성 광원의 홀로그램을 기록할 수 있는 자가 간섭 디지털 홀로그래피 시스템을 이용하여 관찰하고자 하는 물체의 파면을 다각도에서 기록하는 광시야각 홀로그램 촬영 시스템을 개발하였다.

  • PDF

Reliable Deep Learning Based Single-Cam Seat Status Real-Time Detection Solution. (신뢰할 수 있는 딥러닝 기반 단일 캠 좌석현황 실시간 탐지 솔루션)

  • Ko, Seongji;Na, Younghun;Choi, Myunggeun;Hou, Jonguk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.718-720
    • /
    • 2022
  • 신뢰할 수 있는 딥러닝 기반 영상처리 기술을 적용하여 도서관 등 공공장소에서 별도의 센서 없이 하나의 카메라로만 좌석의 점유 사항을 자동으로 검출하여 사용자에게 앱으로 제공하는 솔루션을 제안한다. 라즈베리파이를 이용하며 촬영과 동시에 내부적으로 분석 및 좌석탐지가 진행되며, 촬영된 데이터는 모두 탐지 즉시 휘발된다. 이로 인해 우리의 솔루션은 구조적으로 개인정보 유출 등의 민감한 데이터는 유출될 우려가 없다. 또한 탐지가 완료된 후 결과를 서버로 전송하기 때문에 서버의 처리량이 크게 감소된다. 우리는 이와 같이 신뢰할 수 있고 효율적으로 좌석을 탐지하고 정보를 제공하는 솔루션을 제안한다.

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.

Gradient Noise Reduction in EEG Acquired During MRI Scan (MRI와 동시 측정한 뇌전도 신호에서 경사자계 유발잡음의 제거)

  • Lee H.R.;Lee H.N.;Han J.Y.;Park T.S.;Lee S.Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose : Information about electrical activity inside the brain during fMRl scans is very useful in monitoring physiological function of the patient or locating the spatial position of the activated region in the brain. However, many additional noises appear in the EEG signal acquired during the MRI scan. Gradient induced noise is the biggest one among the noises. In this work, we propose a gradient noise reduction method using the independent component analysis (ICA) method. Materials and Methods : We used a 29-channel MR-compatible EEG measurement system and a 3.0 Tesla MRI system. We measured EEG signals on a subject lying inside the magnet during EPI scans. We selectively removed the gradient noise from the measured EEG signal using the ICA method. We compared the results with the ones obtained with conventional averaging method and PCA method. Results : All the noise reduction methods including the averaging and PCA methods were effective in removing the noise in some extent. However, the proposed ICA method was found to be superior to the other methods. Conclusion : Gradient noise in EEG signals acquired during fMRI scans can be effectively reduced by the ICA method. The noise-reduced EEG signal can be used in fMRI studies of epileptic patients or combinatory studies of fMRI and EEG.

  • PDF

A Study on the Accuracy Evaluation of UAV Photogrammetry using Oblique and Vertical Images (연직사진과 경사사진을 함께 이용한 UAV 사진측량의 정확도 평가 연구)

  • Cho, Jungmin;Lee, Jongseok;Lee, Byoungkil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.1
    • /
    • pp.41-46
    • /
    • 2021
  • As data acquisition using unmanned aerial vehicles is widely used, as one of the ways to increase the accuracy of photogrammetry using unmanned aerial vehicles, a method of inputting both vertical and oblique images in bundle adjustment of aerial triangulation has been proposed. In this study, in order to find a suitable method for increasing the accuracy of photogrammetry, the accuracy of the case of adjusting the oblique images taken at different shooting angles and the case of adjusting the oblique images with different shooting angles at the same time with the vertical images were compared. As a result of the study, it was found that the error of the checkpoint decreases as the angle of the input oblique images increases. In particular, when the vertical images and oblique images are used together, the height error decreases significantly as the angle of the oblique images increases. The current 『Aerial Photogrammetry Work Regulation』 requires RMSE (Root Mean Square Error), which is the same as GSD (Ground Spatial Distance) of a vertical image. When using an oblique images with a shooting angle of 50°, a result close to this standard is obtained. If the vertical images and the 50° oblique images were adjusted at the same time, the work regulations could be satisfied. Using the results of this study, it is expected that photogrammetry using low-cost cameras mounted on unmanned aerial vehicles will become more active.

Utilization of Mammogram in the Tomosynthesis (토모신테시스의 유방촬영에서의 활용)

  • Lee, Mi-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.322-328
    • /
    • 2015
  • This study evaluated the diagnostic value and compares the Mammogram Tomosynthesis, and as compared to the AGD, was studied with respect to utilization of Tomosynthesis. During January 2015 one month were enrolled patients admitted to 62 people present. The ACR phantom was used. AEC was set to be. kVp is fixed and given a step-by-step changing the mAs analyzed AGD. Tomosynthesis was superior to the distinction of breast lesions when compared with Mammogram showed a noticeable difference in contrast. AGD(Average Glandular Dose) was higher 0.33 mGy. However, in the long run, the dose was reduced. Tomosynthesis is therefore increase the diagnostic value of the breast, a examination that can reduce the dose.

A Study on the Impact of an Improved Image Process Technique on the Enhancement of Accuracy in Measuring Water Level (영상처리기술 개선에 따른 수면인식 정확도 향상에 대한 연구)

  • Kwon, Sung-Ill;Kim, Won;Lee, Chan-Joo;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1911-1915
    • /
    • 2010
  • 영상수위계는 카메라에 의해서 수위표를 촬영하여 촬영된 영상을 처리하여 수위값으로 변환하여 자동적으로 수위를 측정하는 장비이다. 이 수위계는 기존 수위측정 장비인 부자식, 압력식, 기포식, 초음파식, 레이다식과는 달리 수위표를 촬영한 영상으로부터 수위를 직접 눈으로 확인할 수 있는 장점이 있다. 이로 인해 영상자료로부터 측정된 수위를 검증할 수 있어 수위측정의 정확도를 향상시킬 수 있다. 그리고 수위표 영상과 더불어 관측지점 주변의 전체 영상을 동시에 촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 수위관측용으로 운영 중인 영상수위계의 수위측정자료를 분석한 결과, 안개가 짙게 낀 경우, 목자판이 오염된 경우, 목자판 내에 그림자가 진 경우 등에서 수면을 인식하지 못하거나 오인식이 발생하였다. 이와 같이 수위 오 결측이 발생하는 경우에 수면을 정확하게 인식할 수 있도록 수위 측정방법을 개선하였다. 영상의 분할 이진화 처리기법, 노이즈 제거 기법, 목자판 영역내의 영상농도에 대한 히스토그램을 통해서 목자판과 수면을 구분하는 기법을 영상처리방법으로 새롭게 적용하였다. 수위 오 결측이 발생하는 영상자료를 이용하여 개선된 영상처리방법의 성능을 검증한 결과, 기존 방법으로는 수면을 전혀 인식하지 못하였던 영상이 개선된 방법을 적용하면 안개가 낀 경우에 약 97%까지, 목자판이 오염된 경우에 약 89%까지, 목자판 내에 그림자가 진 경우에 약 92%까지 수면을 인식하였다. 따라서 이와 같이 개선된 방법을 적용하게 되면 영상수위계의 정확도를 향상시킬 수 있을 것으로 기대된다.

  • PDF

A Study on the Effective Management of Image Stage Gauge System (영상수위계 시스템의 효율적 운영에 관한 연구)

  • Kwon, Sung-Ill;Kim, Won;Lee, Chan-Joo;Kim, Dong--Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1916-1920
    • /
    • 2010
  • 영상수위계는 카메라에 의해서 수위표를 촬영하여 촬영된 영상을 처리하여 수위값으로 변환하여 자동적으로 수위를 측정하는 장비이다. 이 수위계는 기존 수위측정 장비인 부자식, 압력식, 기포식, 초음파식, 레이다식과는 달리 수위표를 촬영한 영상으로부터 수위를 직접 눈으로 확인할 수 있는 장점이 있다. 이로 인해 영상자료로부터 측정된 수위를 검증할 수 있어 수위측정의 정확도를 향상시킬 수 있다. 그리고 수위표 영상과 더불어 관측지점 주변의 전체 영상을 동시에 촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 영상수위계 시스템은 크게 메인제어기, 전원부, 서버부 및 카메라부로 구성되어 있다. 현재 운영되고 있는 시스템은 전원장치 리셋시 전 시스템을 리셋해야하고, 상전 단전시 전 시스템이 off된다. 그리고 별도의 통신모듈을 사용하여 장비간 통신이 이루어지고 있다. 또한 카메라부에는 렌즈와 팬/틸트를 제어하기 위한 별도의 장비가 포함되어 있고, 백색 LED 조명이 사용되어 야간에 수위인식주기마다 조명이 on/off 되고 있다. 위와 같은 전원장치의 운영으로 시스템을 안정적으로 운영할 수 없다. 그리고 수위 오인식을 최소화하기 위해서는 연속적인 수위 인식이 필요하지만, 백색 LED조명과 1초에 2프레임을 캡쳐하는 비디오 캡쳐방식에 의해 시스템을 상시로 운영하는 것이 곤란하다. 현재 운영 중인 영상수위계를 안정적으로 운영할 수 있도록 장비별로 제어가 가능하도록 전원 제어장치를 개발하였고, 상전 단전시 최소 30분 정도 전원을 유지할 수 있도록 무정전전원장치(UPS)를 설치하였으며, 측정자료의 저장장치를 하드디스크 타입에서 Flash SSD 메모리 타입으로 교체하였다. 또한 영상수위계 시스템을 상시 운영할 수 있도록 백색 LED조명을 적외선 LED조명으로 교체하였고, 1초에 1회 수위를 인식하도록 수위인식주기와 1초에 25프레임 캡쳐할 수 있도록 비디오 캡쳐방식을 개선하였다. 위와 같은 시스템의 개선으로 시스템을 안정적으로 운영할 수 있게 되어 시스템 고장에 의해 발생하는 수위 결측을 감소시킬 수 있고, 시스템의 상시 운영으로 수 위 오인식을 최소화시킬 수 있을 것으로 판단된다.

  • PDF