• Title/Summary/Keyword: 동기 노치 필터

Search Result 5, Processing Time 0.022 seconds

Comparative Study of Performance of Switching Control and Synchronous Notch Filter Control for Active Magnetic Bearings (능동 자기 베어링을 위한 동기 노치필터 제어기와 스위칭 제어기의 성능 비교 연구)

  • Yoo, Seong Yeol;Noh, Myounggyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.511-519
    • /
    • 2013
  • Switching controllers for active magnetic bearings are claimed to minimize the copper losses because they do not use bias currents. In this study, we compare the performances of the switching controller with those of the widely used proportional-derivative (PD) controller. The PD controller is combined with a synchronous notch filter to reduce the effect of the unbalance disturbance. For a fair and objective comparison, the PD controller is designed systematically. The switching controller is designed so that the dynamics of the two controllers are almost identical. A system model is developed. This model includes the flexible modes of the rotor and the dynamics of the sensors and amplifiers. The simulation results show that the switching controller indeed reduces the copper loss at lower speeds. However, it fails to operate around the speed close to the bending mode of the rotor.

Sensorless Operation of Low-cost Inverters through Square-wave High Frequency Voltage Injection (사각 고주파 주입을 통한 저가형 인버터의 센서리스 운전)

  • Hwang, Sang-Jin;Lee, Dong-Myung
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.95-103
    • /
    • 2022
  • In this paper, the efficiency of a sensorless method with square-wave injection for a low-cost inverter, so called B4 inverter is presented. This inverter comprises only 4 switches to reduce system cost. It is distinguished from the conventional B6 inverter that has 6 of switching elements. The B4 inverter, injected a 1 kHz of harmonic wave, has been modelled using the functions and library in Matlab/Simulink. This paper described each component of sensorless algorithm. Among them, the Notch Filter is used to extract the harmonic component of the phase current and a second-order low-pass filter was used to reduce the ripple of the estimated speed. It is shown through simulation that the rotor angle of a permanent magnet synchronous motor is detected by multiplying the current waveform extracted using the notch filter by the harmonic voltage. The feasibility of the proposed method is shown through Simulink simulation.

Improved grid synchronization technique based on adaptive notch filter (노치 필터 기반의 개선된 계통 동기화 기법)

  • Jung, Hoon-Young;Ji, Young-Hyok;Kim, Jae-Hyung;Lee, Su-Won;Won, Chung-Yuen;Kim, Jin-Uk;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.209-211
    • /
    • 2009
  • A digital grid synchronization technique is needed for distributed generation system to make output current sinusoidal even if the grid voltage is distorted by harmonics. In this paper, a digital grid synchronization technique based on adaptive notch filter is proposed. The analysis of proposed technique is performed through the consideration of grid synchronization technique based on PLL and FLL, and the validity of the proposed method was confirmed by simulation results.

  • PDF

Automatic Tuning of Notch Filter to Suppress Oscillations in a PMLSM Drive (선형 영구자석 동기전동기 구동장치의 진동억제를 위한 노치필터 자동조정)

  • Lee, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.409-411
    • /
    • 2007
  • This paper deals with an automatic tuning method of the notch filter to suppress oscillations in a permanent magnet linear synchronous motor(PMLSM) drive. First, it saves automatically the reference torque-component current when oscillations are detected. Then the oscillation frequency of the saved data is calculated by using the fast Fourier transform(FFT) algorithm. And also the Hanning function is used to reduce the leakage components due to the aperiodic measurement data. Finally, the proposed method tunes the notch filter to suppress oscillations. Experimental results on the test rig show the validity of the proposed method.

  • PDF

Digital Linear Control System for a Magnetic Bearing System of a High Vacuum Turbomolecular Pump (고진공 터보 분자펌프용 자기베어링 시스템의 디지털 선형 제어시스템)

  • Ro, Seung-Kook;Kyung, Jin-Ho;Park, Jong-Kweon;Nam, Woo-Ho;Koh, Deug-Yong
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.256-264
    • /
    • 2010
  • In this paper, a digital controller of magnetic bearing system for a high vacuum turbomolecular pump (TMP) is designed and examined. For stabilizing and providing damping in magnetic bearing, the digital PID controller is applied for each 5 control axes, and the inter-axis cross feedback controller is also applied to suppress low frequency vibration caused by gyroscopic moment of the rotor at high speed of rotation. The fabricated rotor-shaft has its first flexible natural frequency lower than maximum speed, about 614Hz, so the two lead filters are applied to increase damping of flexible mode. Notch filters with rotating frequency were selected to reduce vibration of the pump housing caused by unbalance load. The implemented controllers are verified by examination of frequency response and rotating test up to 40,000 rpm, which is higher than critical speed of backward flexible mode.