• Title/Summary/Keyword: 동결층

Search Result 116, Processing Time 0.023 seconds

The statistical factors affecting the freezing of the road pavement (도로포장체의 동결에 영향을 미치는 통계적 요인)

  • Kim, Hyun-Ji;Lee, Jea-Young;Kim, Byung-Doo;Cho, Gyu-Tae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.1
    • /
    • pp.67-74
    • /
    • 2016
  • Due to the character of the climate of Korea, the pavement of a road is Influenced by freezing in winter season and thawing in thawing season. In the last few years, several articles have been devoted to the study to minimize the damage of freezing and thawing action. The purpose of this paper is to identify appropriacy of factors that influence road pavement thickness. We conduct the decision tree analysis on the field data of road pavement. The target variable is 'Frost penetration'. This value was calculated from the temperature data. The input variables are 'Region', 'Type of road pavement', 'Anti-frost layer', 'Month' and 'Air temperature'. The region was divided into 9 regions by freezing index $350{\sim}450^{\circ}C{\cdot}day$, $450{\sim}550^{\circ}C{\cdot}day$, $550{\sim}650^{\circ}C{\cdot}day$. The type of road pavement has three-section such as area of cutting, boundary area of cutting and bankin, lower area of banking. As the result, the variables that influence 'Frost penetration' are Month, followed by anti-frost layer, air temperature and region.

An Experimental Study on Freezing Behavior of NaCl and Heavy Metal Aqueous Solution Using Freeze Concentration Method (동결농축법을 이용한 염수 및 중금속 수용액의 동결거동에 관한 실험 연구)

  • Kim, Jung-Sik;Lim, Seung-Taek;Oh, Cheol
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.129-135
    • /
    • 2013
  • Recently, waste water treatment system is developed in small and middle size to get more economic advantage. Freeze concentration system has high thermodynamic efficiency and low energy consumption, can re-use purified water and cold energy obtained from ice. This study was experimentally performed to investigate pollution containment in frozen layer by cooling wall temperature, air-bubble flow methods, initial ice-lining thickness of frozen layer in NaCl aqueous solution and the representative heavy metals, Pb and Cr aqueous solution. As the result, a decrease in the cooling wall temperature bring a higher growth rate of ice front and the more solute was involved in frozen layer. The method to inject directly air-bubble into ice-liquid interface through ring shape nozzle gave high purity of ice compared to indirect method. Ice lining in 5mm thickness resulted in frozen layer with higher purity than 1mm thickness.

Computing Procedure of Daily Average Air Temperature using Field Data and Frost Index Calibration for Anti-Frost Heave Layer Design (현장계측 데이터를 이용한 일평균 대기온도 산정방법과 동상방지층 설계를 위한 동결지수 보정)

  • Cho, Myung-Hwan;Kim, Nakseok;Shim, Jaepill
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3D
    • /
    • pp.433-439
    • /
    • 2011
  • The frost depth(frost penetration) is used to install anti-frost heave layers in pavement designs. The freezing index is calculated by an annual accumulated value of multiplying the period of time with temperatures below zero, and the corresponding temperature. Therefore, the DAAT(daily average air temperature) calculation method may play an effect on the FI(freezing index). The Weather Observatory used to supply 4 average air temperatures per day, but currently supplies 8 per day. With this study, we divided the southern part(below FI=$350^{\circ}C{\cdot}day$) of the Korean peninsula into 6 areas according to site conditions(low embankment, embankment-cutting slope, and the cutting slope) and established a field measurement system for 15 positions to check the effects on the result of FI according to differing DAAT calculation methods. The air temperatures obtained by the field measurement system was used to calculate and compare the FI. As a result, the freezing index calculated based on the $DAAT_4(T_4)$ is normally greater by 3% than the one on $DAAT_8(T_8)$. In addition, the calibration equation for the freezing index using air temperatures was proposed through the research.

Development of Prediction Model of Frost Penetration Depth on Pavement in Korea (포장도로의 실측값을 활용한 한국형 동결깊이 예측모델 개발)

  • Hong, Seung-Seo;Kim, Young-Seok;Kim, Hak-Seung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.3
    • /
    • pp.47-56
    • /
    • 2010
  • Korea is known to have seasonal frozen ground during a winter season due to climatic and ground conditions. Temperatures below $0^{\circ}C$ cause pavement failure by frost heaving and thaw settlement. A frost protection layer has been constructed in pavements to avoid damage caused by frost action. Anti-frost design methods in Korea have been adopted, which is established in U.S. and Japan. However the characteristics of soils in Korea are different and there are no reasonable modifications to accommodate these characteristics. Therefore, adequate pavement design procedures including seasonal frost action, as well as construction and maintenance practices are required. In this paper, the frost penetration depths along national roads in Korea are presented based on field measurement over several years (1991~2010). The frost penetration depths are analyzed with respect to the Provinces of Korea and sunny/shaded areas.

  • PDF

An Establishment of Database for Effective Design of Anti-Frost Heave Layer using Field Data (도로포장의 효율적 동상방지층 설계를 위한 현장 계측자료의 데이터베이스(DB) 구축)

  • Kim, Nak-Seok;Nam, Young-Kug;Cho, Gyu-Tae;Lee, Bum-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.43-47
    • /
    • 2011
  • Korea has seasonal weathers which result in the frosting of soil in winter times, and the thawing of soil in spring. These climate characteristics result in the damaging of pavements, due to the repeated freezing and thawing of road pavements during winter and spring. In order to reduce these pavement damages, anti-frost heave layers are being specially installed, however it is being applied based on foreign researches, and therefore result in the waste of national budget. With this study, a database system was constructed for effective management and monitoring of measured temperatures and function data of 2 meters below the embankment, cut slope, and the cutting-embankment boundary, which are 15 regions picked by the frost index diagram. As the study result, an effective storage and management-purpose database was established for easy data searching and downloading for the pavement design engineers.

A Experimental Study on Waste Water Concentration by Separating Method of Freezing (동결분리방법을 이용한 폐수농축에 관한 실험적 연구)

  • Kim, Jung-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.51-52
    • /
    • 2006
  • This study was progressed on the freezing behavior of waste water in relation to freeze concentration method useful to waste water treatment system of small and middle size and which can re-use purified water. The object of this experiment is comparing a pollutant contain of the frozen layer and of an aqueous solution by cooling wall temperature, a flow field effect and a initial thickness of frozen layer.

  • PDF

Verification of Freezing Index and Frost Penetration Depth with Temperature Data of Korea LTPP (국내 LTPP 온도 자료를 이용한 동결지수와 동결깊이 검증 연구)

  • Kim, Boo-Il;Jeon, Sung-Il;Lee, Moon-Sup;Lim, Kwang-Su
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.143-152
    • /
    • 2009
  • The purpose of this study is to evaluate the freezing index and frost penetration depth. The freezing index and frost penetration depth were analyzed using air temperature and temperature profile of pavement system in Korea LTPP-SPS(Long Term Pavement Performance-Specific Pavement Study) site. The predicted frost penetration depth were then compared with the measured one from the LTPP sites. And the trend of annual freezing index was analyzed using the temperature data of meteorological stations located in the vicinity of Korea LTPP-SPS site. The result showed that the freezing index was rapidly decreased since 1987, and it was known that the use of freezing index determined from the past 30 years temperature data could cause the over estimates in the pavement thickness design. The temperature profile measured at 3 sections of LTPP-SPS sites showed that the temperature of subbase layer was above $0^{\circ}C$, even though anti-frost layers were found in these sections. Comparing the measured and calculated frost depth, the frost depth calculated from the subgrade frost penetration permissible method showed a similar trend with the measured frost depth.

  • PDF

Effect of Computing Procedure of Average a Daily Air Temperature on Frost Index determination (일평균 대기온도 산정방법이 동결지수 결정에 미치는 영향)

  • Cho, Myung-Hwan;Kim, Nakseok;Lee, Yoon-Han;Jin, Junghoon
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.83-83
    • /
    • 2011
  • 도로의 동상방지층을 설치하기 위하여 동결관입깊이를 산정하며, 동결지수는 대기온도의 강도와 지속시간의 누가영향으로 표시된다. 대기온도는 일평균 대기온도를 사용하며 4개/일 평균(대기온도$_4$)을 사용하는 것이 일반적이지만, 현재 기상청에서 제공하고 있는 일평균 대기온도는 8개/일(대기온도$_8$)를 제공하고 있다. 이러한 일평균 대기온도의 산정하는 방법이 동결지수의 산정결과에 미치는 영향을 확인하기 위하여 한반도 남부지역(동결지수 $350^{\circ}C{\cdot}$일) 미만 6개지역을 저성토부, 절성경계부 및 절토부로 구분하여 15개소에 대하여 현장계측시스템을 구축하였다. 그리고 현장계측 시스템으로부터 얻어진 대기온도를 통하여 동결지수를 산정하여 비교하였다. 동결지수 비교결과 일반적으로 일평균 대기온도$_4$를 사용한 경우가 일평균 대기온도$_8$을 사용하는 경우보다 약 3% 전후 큰 것으로 나타나났으며, 6개 지역의 동결지수를 결정할 때 대기온도$_8$을 사용한 동결지수를 보정할 수 있는 보정식을 제안하였다.

  • PDF

A Characteristic of Freeze and Thaw on Use for Stabilized Soil in Landfill Bottom Liners (매립지 바닥층의 고화토 포설시 동결/융해의 특성)

  • Kim, Heung-Seok;Lee, Song;Lee, Jai-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.1
    • /
    • pp.29-39
    • /
    • 2006
  • Recently, Korea brings to remarkable levels about industrialization, modernization, population and development of technology. Especially, the rapidly growing from this technology has increased the burden on existing industrial waste landfills. The purpose of this research is to existing knowledge base of landfill cover liner behavior during periods freeze/thaw. Although these tests have been invaluable in clarifying the problem of freeze/thaw, extending the results of such experimental studies to prototype landfills are questionable. For this investigation, the author utilized a large scale laboratory simulation allowing inclusion of the field depth of the cover systems, layered soil profiles, rainfall simulation, a cold climate and boundary conditions similar to those encountered in the landfill. And the soil materials used stabilized soils (mixed clays, cements, and minerals) instead of clays. The bottom liners are made up of drainage layer (30cm), stabilized layer (75cm), and leach collection layer (60cm). The stabilized layers are made up of supporting layer (45cm) and impermeable layer (30cm) - consisted of $P_A$ and $P_B$ layer.

  • PDF

Prediction of the Drying Time under the Various Operational Conditions using a Sublimation Model (승화 건조모델에 대한 운전방법별 건조시간의 예측)

  • 박노현;배신철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.8
    • /
    • pp.2088-2098
    • /
    • 1993
  • A mathematical model of freeze drying by sublimation was suggested and used to estimate the drying time. Under the various conditions, the drying time of pure water and carrot was numerically calculated for the suggested model. Optimal policies of freeze drying were investigated experimentally in a laboratory freeze dryer. It was found that the shortest drying times could be obtained when the chamber pressure and condenser temperature were kept at their lowest values and the best method of heat transfer for sublimation was the conduction involving radiation. The sublimation drying period was finished when the bottom temperature of material could be reached at near $0^{\circ}C$ from frozen temperature.