• Title/Summary/Keyword: 돈사

Search Result 426, Processing Time 0.023 seconds

Piggery Waste Treatment using Partial Nitritation and Anaerobic Ammonium Oxidation (부분질산화와 혐기성 암모늄산화를 이용한 돈사폐수처리)

  • Hwang, In-Su;Min, Kyung-Sok;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.599-604
    • /
    • 2006
  • Nitrogen removal with the combined SHARON (Single reactor system for high ammonium removal over nitrite)ANAMMOX (Anaerobic ammonium oxidation) process using the effluent of ADEPT (Anaerobic digestion elutriated phased treatment) slurry reactor with very low C/N ratio for piggery waste treatment was investigated. For the preceding SHARON reactor, ammonium nitrogen loading and removal rate were $0.97kg\;NH_4-N/m^3_{reactor}/day$ and $0.68kg\;NH_4-N/m^3_{reactor}/day$ respectively. In steady state, bicarbonate alkalinity consumption for ammonium nitrogen converted to $NO_2-N$ or $NO_3-N$ was 8.4 gram per gram ammonium nitrogen. The successive ANAMMOX reactor was fed with the effluent from SHARON reactor. The loading and removal rate of the soluble nitrogen defined as the sum total of $NH_4-N$, $NO_2-N$ and $NO_3-N$ in ANAMMOX reactor were $1.36kg\;soluble\;N/m^3_{reactor}/day$ and $0.7kg\;soluble\;N/m^3_{reactor}/day$, respectively. The average $NO_2-N/NH_4-N$ removal ratio by ANAMMOX was 2.41. Fluorescence in situ hybridization (FISH) analysis verified that Candidatus Kuenenia stuttgartiensis were dominate, which means that they played an important role of nitrogen removal in ANAMMOX reactor.

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

The Treatment of Slurry-type Swine Waste using UASB Reactor (UASB 공정에 의한 슬러리형 돈사폐수의 처리)

  • Won, Chul-Hee;Kim, Byoung-Ug;Han, Dong-Joon;Rim, Jay-Myoung
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.583-588
    • /
    • 2004
  • This research examined the treatment efficiency and methane production rate in treating slurry-type swine waste using UASB (upflow anaerobic sludge blanket) reactor. The UASB reactor was operated at an organics volumetric loading rate (VLR) of $2.6-15.7kgCOD/m^3/day$. A stepwise increase of the VLR resulted in a temporary deterioration in the COD removal rate in UASB reactor but recovered quickly. The COD removal rate were 65-70% for VLR up to $5 kgCOD/m^3/day$. When organics VLR was $10kgCOD/m^3/day$, the COD removal rate decreased sharply and there was loss of 17.537g of the seeding biomass due to sludge washout. This result indicated that the UASB system cannot be adapted to more than $10kgCOD/m^3/day$ of VLR. As the organic load increased from 2.6 to $15.7kgCOD/m^3/d$, the biogas production rate varied from 3.2 to 10.8 L/d and the methane conversion rate of the organic matter varied from 0.30 to $0.23m^3CH_4/kg\;COD_{removed}$. The methane content showed the range of 70.1-81.5% during the experimental period. The volatile solids (VS) removal efficiency was similar at the low VLR (< $5 kgCOD/m^3/day$), but it decreased sharply at the high VLR (> $5 kgCOD/m^3/day$). The VS reduction rate was, moreover, large those of COD. The result shows that hydraulic retention time above 2 days is essential in case of treating wastewater containing 1% of solids.

Characteristics of Pollutant Concentration from Livestock Wastewater Effluent Combined with Stormwater Runoff (강우시 및 건기시 축산지역에서 배출되는 오염물질의 유출특성 비교)

  • Tobio, Jevelyn Ann S.;Maniquiz-Redillas, Marla C.;Lee, Yuwha;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.896-901
    • /
    • 2012
  • In this research, the levels of concentrations from the junction of effluent from wastewater treatment plant during dry days and combined with runoff from the surrounding 11 ha livestock catchment area during wet days were determined to investigate the relationships of the concentration of various pollutants such as particulates, nutrients and organics originating from point and nonpoint sources. Manual sampling was conducted from October 2008 to December 2011 during dry and wet days. Based on the results, the flow rates and concentrations of most pollutant parameters were increased during wet days. It was found out that the effluent wastewater combined with stormwater runoff has low BOD to TN/TP ratio and high TN/TP to BOD ratio. Therefore, it is needed to employ other treatment methods to effectively manage the wastewater and reduce the pollutant discharge to receiving water bodies.

Development of a CFD Model to Study Ventilation Efficiency of Mechanically Ventilated Pig House (강제환기식 돈사의 환기 효율성 분석을 위한 CFD 모델 개발)

  • Seo, Il-Hwan;Lee, In-Bok;Hong, Se-Woon;Hwang, Hyun-Seob;Bitog, Jessie Pascul;Yoo, Jae-In;Kwon, Kyung-Suk;Ha, Tae-Hwan;Kim, Hyeon-Tae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.1
    • /
    • pp.25-37
    • /
    • 2008
  • When livestock facilities in Korea have been changed larger and denser, rearing conditions have been getting worse and the productivity of animal production have been decreased. Especially in the cold season, the minimized ventilation has generally been operated to save energy cost in Korea resulting in very poor environmental condition and high mortality. While the stability, suitability, and uniformity of the rearing condition are the most important for high productivity, the ventilation configuration is the most important to improve the rearing condition seasonally. But, it is so difficult to analyze the internal air flow and the environmental factors by conducting only field experiment because the weather condition is very unpredictable and unstable as well as the structural specification can not be easily changed by the researchers considering cost and labor. Accordingly, an aerodynamic computer simulation was adopted to this study to overcome the weakness of conducting field experiment and study the aerodynamic itself. It has been supposed that the airflow is the main mechanism of heat, mass, and momentum transfers. To make the simulation model accurately and actually, simplified pig models were also developed. The accuracy of the CFD simulation model was enhanced by 4.4 % of errors compared with the data collected from field experiments. In this paper, using the verified CFD model, the CFD computed internal rearing condition of the mechanically ventilated pig house were analyzed quantitatively as well as qualitatively. Later, this developed model will be computed time-dependently to effectively analyze the seasonal ventilation efficiency more practically and extensively with tracer gas decay theory.

Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology (전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Bitog, Jessie.P.;Hong, Se-Woon;Seo, Il-Hwan;Choi, Ji-Sun;Song, Sang-Hyeon;Moon, Oun-Kyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

Field Survey of structural and Environmental Characteristics of Pig Houses in the Southern Provinces in Korea (전업양축농가를 위한 남부지방 돈사의 구존 및 환경실태조사)

  • 최홍림;송준익;안희권
    • Journal of Animal Environmental Science
    • /
    • v.6 no.1
    • /
    • pp.1-14
    • /
    • 2000
  • The structural and environmental characteristics of typical pig houses in different growth phases were surveyed and analyzed. Based on the data for thirty nine selected farms in four provinces, Jeonbuk-do, Jeonnam-do, Gyeongbuk-do, and Gyeongnam-do, in the southern provinces, Korea, the goal is to eventually establish standard pig houses of sow and litter, nursery pigs, and growing-finishing pigs. The survey included farm scale, production specialization, structural dimensions of the houses and their ventilation systems, cooling and heating systems, and floor and pit systems related to manure collection. The survey showed 90∼98% of growing-finishing pig houses adopted the sidewall curtain systems. The sidewall curtain systems, although popular, is not well insulated which leads to excessive heating costs in winter. Regarding flooring and manure collection system of the house, 23∼35% of growing-finishing houses installed scraper systems with concrete-slat floors in Gyeongsang provinces while 52∼78% did in Jeolla provinces. The cause of a large variance in flooring between tow regions could not be academically pinpointed, rather it could be attributed to the advice of neighbors who leads local pig production circle. A general trend toward enlargement and enclosure of pig houses for all growth phases was gaining popularity in most regions in recent years. A steady shift to multisite operation from continuous operation was also observed to prevent a disease transfer. The structural design of a standard pig house with its environmental control systems including ventilation and heating/cooling system was suggested for further validation study. In-depth analysis of the survey data is presented in the Results and Discussion section.

  • PDF

Environmental Analysis of a Windowless Delivery Swine Building : Temperature and Relative Humidity (무창분만돈사의 온.습도 환경 분석)

  • 이성현;조한근;장유섭
    • Journal of Animal Environmental Science
    • /
    • v.3 no.2
    • /
    • pp.77-85
    • /
    • 1997
  • Recently, local swine producers are rapidly adopting the indoor production system which developed in foreign countries. However, this imported system is reported as not functioning properly because of different climate conditions. The objective of this project was to investigate the environment characteristics of a windowless delivery swine building. The parameters studied were the heating and cooling loads, the daily changes of indoor temperature and relative humidity, the horizontal and the vertical distributions of indoor temperature, and the effect of mist cooling on indoor temperature. From this study, the following are founded : 1. The maximum cooling and heating loads were - 317.0kcal/㎡$.$h and 336.5kal/㎡$.$h in summer and in winter. The large loads seems to be on account of inappropriate operations of ventilating fans. 2. The daily variations of relative humidity in indoor were smaller than those in outside. Those values both in summer and in winter as relative humidities in door was lower than optimum for growing pigs, the additional humidifier might be helpful to increase the relative humidity in indoor. 3. The horizontal distribution of the indoor temperature was found to be uniform in the variation range of 1$^{\circ}C$. 4. The vertical distribution of the indoor temperature was not found to be uniform; the temperature of upper part was higher than that of slot part. 5. Average values of indoor temperature became lower by 3$^{\circ}C$ by mist cooling. But the variation of temperature was found to be larger; The middle part of the room was cooled down, but the corner part of the room was not affected by misting due to uneven nozzle configuration.

The Comparison of Concentration of Volatile Fatty Acids, Ammonia, and Volatile Organic Compounds in Pig Slurry (돈사 종류별 슬러리의 악취물질 농도 비교)

  • Cho, Sung Back;Yang, Seung Hak;Lee, Jun Yeop;Kim, Jung Kon;Jeon, Jung Hwan;Han, Man Hee;Han, Duck Woo;Jeong, Gwang Hwa;Kwag, Jeong Hoon;Choi, Dong Yun;Hwang, Ok Hwa
    • Journal of Animal Environmental Science
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2013
  • This study was performed to analyse the concentration of odorous compounds in the piggeries. Piggeries for different types of pigs include piglets, growing pigs, gestating and lactating sows. Slurry from these piggeries was sampled every month for chemical analysis. Short chain fatty acid (SCFA) was 9,862 ppm (piglet), 8,410 ppm (growing pigs), 6,791 ppm (fattening pigs), 3,508 ppm (lactating sows) and 1,687 ppm (gestating sows). Branched chain fatty acid (BCFA) was 1,634 ppm (piglet), 1,206 ppm (growing pigs), 868 ppm (fattening pigs), 493 ppm (lactating sows) and 185 ppm (gestating sows). Concentration of phenols was 209 ppm (piglet), 166 ppm (growing pigs), 127 ppm (fattening pigs), 85 ppm (lactating sows) and 36 ppm (gestating sows). Indoles was 18 ppm (piglet), 14 ppm (growing pigs), 8 ppm (fattening pigs), 6 ppm (lactating sows) and 4 ppm (gestating sows). Altogether, concentration of odorous compounds was decreased as pigs got aged.