• Title/Summary/Keyword: 도플러 초음파

Search Result 185, Processing Time 0.039 seconds

MIMO Vector Channel Modeling and Performance Analysis in Underwater Channel Environments (수중 MIMO 벡터 채널 모델링 및 성능 분석)

  • Lee, Deok-Hwan;Ko, Hak-Lim;Lim, Yong-Kon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.8
    • /
    • pp.426-431
    • /
    • 2007
  • In this paper we have studied the underwater vector channel modeling for MIMO(Multiple Input Multiple Output) to increase the performance and efficiency for ultrasound communication in underwater channel environments. Also we have analyzed the MIMO techniques using the proposed channel modeling. For underwater MIMO channel modeling. experiments were done in real channel environments and the data were analyzed to estimate parameters such as fading, Doppler, time delay, angle of arrival, and receiving power. These were used for modeling of underwater vector channel modeling for MIMO. Additionally, we have analyzed the performance of MIMO systems using our proposed channel models. As a result we could see that the BER has decreased severely with the same SNR when using the MIMO system.

Unusual Presentation of a Testicular Lymphoma Mimicking a Missed Testicular Torsion: A Case Report (계류 고환염전으로 오인된 드문 형태의 고환 림프종: 증례 보고)

  • Mi Jin Kim;Young Hwan Lee;Youe Ree Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1287-1291
    • /
    • 2021
  • Testicular lymphoma is an uncommon testicular tumor that usually presents as a painless mass. It usually shows hypervascularity on color Doppler ultrasound (US) and a mild enhancement on enhanced CT or MRI. We present an unusual case of a testicular lymphoma mimicking a missed testicular torsion in a 67-year-old male patient with right scrotal swelling and intermittent pain for 2 months. Color Doppler US demonstrated the absence of vascularity in the enlarged right testis, and the initial diagnosis was a missed testicular torsion. CT demonstrated a poorly enhancing mass rather than a missed testicular torsion with enhanced small nodular foci at the periphery. The final pathological diagnosis was testicular lymphoma.

Restrictive Cardiomyopathy in a Korean Domestic Short-haired Cat (코리안 숏헤어 고양이의 제한성 심근병증)

  • Nam, Hyo-Seung;Han, Suk-Hee;Choi, Ran;Lee, Seung-Gon;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.242-246
    • /
    • 2012
  • A 3-year-old castrated male Korean domestic short-haired cat (weighing 5.2 kg) was referred to the Kangwon National University Veterinary Teaching Hospital, with primary complaints of ascites, pleural effusion and respiratory distress. Diagnostic studies revealed marked chylous and hemorrhagic pleural effusion, cardiomegaly, restrictive filling pattern of transmitral flow and mitral annular tissue Doppler profiles and minimally thickened left ventricular free wall. Based on the echocardiographic findings, the case was tentatively diagnosed as restrictive cardiomyopathy. The case was treated with removal of pleural effusion and medical therapy including furosemide, enalapril, sildenafil, clopidogrel. This is the first case report of restrictive cardiomyopathy in Korea.

Concurrent Medullary Carcinoma and Hashimoto's Thyroiditis: A Case Report with an Emphasis on US Features (하시모토 갑상선염과 동반된 갑상선 수질암의 증례 보고: 초음파 소견을 중심으로)

  • Hyoung Yeob Kim;Noh Hyuck Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1146-1151
    • /
    • 2023
  • Medullary thyroid carcinoma (MTC) is a rare malignancy that originates from the parafollicular cells of the thyroid gland. Hashimoto's thyroiditis (HT) is an autoimmune thyroid disease and is the most common cause of hypothyroidism. Previous studies have frequently discussed the association among HT, papillary thyroid carcinoma, and thyroid lymphoma. However, there have been few reports on the ultrasonographic findings of concomitant HT and MTC. In the present case, a heterogeneous hypoechoic background parenchymal echogenicity, with intraglandular echogenic strands, and increased vascularity were observed. A concurrent, ill-defined, parallel-oriented, heterogeneous hypoechoic mass with central microcalcifications was located at the left thyroid gland, consistent with reported US findings of medullary thyroid carcinoma except for an ill-defined margin in our case.

Ultrasonographic and Magnetic Resonance Imaging Findings of Testicular Lymphoma (고환림프종의 초음파검사 및 자기공명영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.105-112
    • /
    • 2010
  • Purpose : To evaluate the specific radiologic findings of testicular lymphoma which will be able to differentiated from other testicular tumors. Materials and Methods : Pathologically confirmed eight cases were included in this study. All eight cases were performed ultrasonography and four cases were performed magnetic resonance image. On ultrasonography, the size, location, shape, margin, internal echogenicity, homogeneity and vascularity were evaluated. On magnetic resonance image, the shape, margin, homogeneity, signal intensity on T1- and T2-weighted images, degree and homogeneity of the contrast enhancement and contrast enhancement change on dynamic enhancement study. Results : The margin of the mass was smooth on 6 of 8 patients. Internal echogenicity of the mass lesion was hypoechoic than normal testicular parenchyme on 7 of 8 patients. Four cases were homogeneous, 3 cases were relatively homogeneous and 1 case was heterogeneous. All 8 cases showed increased vascularity. The mass lesion was iso-signal intensity on T1-weighted image and low-signal intensity on T2-weighted image. All four cases were enhanced homogeneously and mildly than enhancing normal testicular parenchyme. On dynamic enhancement study, the mass lesion is progressively enhanced with time. Conclusion : The possibility of testicular lymphoma should be considered when testicular mass was homogeneously hypoechoic and low signal intensity on T2-weighted image in old age patients.

  • PDF

A study on the implementation of multi-velocity log system using ultrasonic doppler effect (초음파 도플러 효과를 이용한 선박 종합 속도 측정 시스템 구현에 관한연구)

  • 류점수;신동우;민경선;김영길;강동균;임종곤
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.38-46
    • /
    • 1996
  • In this paper, a multi-velocity log system which uses ultrasonic pulsed doppler signal is developed. The output of the system is the absoluted velcocity of the ship. By using digitral signal processing, we get the vector velocity which displays the ship's speed about fore, aft, port and starboard. And this system give us the information about depth. This multi-velocity system has a large merit that is bottom and water track velocity. In addition, this has the high accuracy and can measure the water-depth according to the deep mode. And the fish finder, echo sounder or docking system will be made by applying the speed log system.

  • PDF

A New Mean Frequency Extension Method in Doppler System (초음파 도플러 시스템에서 새로운 평균 주파수 확장 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.183-190
    • /
    • 1995
  • The use of ultrasound pulsed Doppler systems has become increasingly popular due to the advantages of easy measurements of blood velocity, volume blood blow, and irregularities of the circulatory system. However, the 2-D Doppler systems have several problems, such as range ambiguity, low signal to noise ratio, and slow frame rate. The mean frequency aliasing problem originating from the pulse repetition frequency is one of major limitations in pulsed Doppler systems. A conventional approach to resolve this problem is tracking the mean frequency close to and beyond the Nyquist frequency along the temporal axis. In this paper, a new concept of tracking the mean frequency along the spatial axis is proposed. The proposed technique is fault tolerant by nature and more suitable for multi gate and 2-D Doppler system than conventional methods.

  • PDF

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

Analysis of Calibration Facilities for Acoustic Doppler Current Profilers (ADCPs) (초음파 도플러 유속계 교정 시설 현황)

  • Lee, Jung-Han;Hwang, Keun-Choon;Kim, Eun-Soo
    • Ocean and Polar Research
    • /
    • v.33 no.2
    • /
    • pp.171-183
    • /
    • 2011
  • Despite technological developments and application advances of Acoustic Doppler Current Profilers (ADCPs), no standard procedure has been adopted or accepted for calibration of ADCPs. Limitations of existing facilities for calibrating ADCPs, the complexity of ADCP instruments, and rapid changes in ADCP technology are some of the reasons why a standard procedure has not been adopted. However, there is increasing realization of the need for effective Quality Assurance (QA) and as part of that the importance of standardized calibration. In this study, the significance of calibration and QA plans for ADCPs is discussed and the calibration facilities for ADCPs at home and abroad are reported. Furthermore, the method for calibrating ADCPs using a towed car and its limitations are discussed. This study contributes to discussions surrounding the establishment of standard procedures for calibrating ADCPs and QA plans, and the construction of calibration facilities in the future.

A study on the development of CW(Continuous-Wave) Doppler system for measuring bi-directional blood flow information. (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • Kang, Chung-Sin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1239-1242
    • /
    • 1987
  • With the convention CW Doppler velocity meter, bi-directional velocities cannot be separated. The new CW Doppler system usee quadrature detection and phase rotation to Produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, can easily differentiate typical artery flow from vein flow. and measure both velocity characteristics qualitatively.

  • PDF