• Title/Summary/Keyword: 도시가스 배관망

Search Result 14, Processing Time 0.02 seconds

Multi-block PCA for Sensor Fault Detection and Diagnosis of City Gas Network (도시가스 배관망의 고장 탐지 및 진단을 위한 다중블록 PCA 적용 연구)

  • Yeon-ju Baek;Tae-Ryong Lee;Jong-Seun Kim;Hong-Cheol Ko
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.38-46
    • /
    • 2024
  • The city gas pipeline network is characterized by being widely distributed and hierarchically connected in a complex manner over a wide area. In order to monitor the status of the widely distributed network pressures with high precision, Multi-block PCA(MBPCA) is recommended. However, while MBPCA has excellent performance in identifying faulty sensors as the number of sensors increases, the fault detection performance deteriorates, and also there is a problem that the model needs to be updated entirely even if minor changes occur. In this study, we developed fault detectability index and fault identificability index to determine the effectiveness of MBPCA application block by block. Based on these indices, we distinguished MBPCA and PCA blocks and developed a fault detection and diagnostic system for the city gas pipeline network of Haean Energy Co., Ltd., and were able to solve the problems that arise when there are many sensors.

A Study on Pipeline Network Analysis for Predicting Pressure and Flow rate Transients in City-gas Supply Lines (도시가스 공급라인의 압력 및 유량변화 예측을 위한 배관망 해석 연구)

  • Nam, Jin-Hyun;Cho, Chan-Young;Jang, Sung-Pill;Lim, Si-Hyung;Shin, Dong-Hoon;Chung, Tae-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.85-91
    • /
    • 2008
  • The deviation of measured pressures in pipeline networks from normal or reference pressures is useful information for judging the operation of the pipeline networks. A cost-effective monitoring of pipeline networks including a leak detection capability can be realized when transient pressure variation is accurately predicted using measured conditions at supply- and demand-sides of the networks. In this study, a pipeline network analysis program was developed based on one-dimensional flow equations for compressible fluids. The validity of the present analysis was demonstrated by simulating the flow in a straight pipeline and comparing the results with the previously reported ones. Pressure and flow rate transients in several simple city-gas pipeline networks were also analyzed to show the usefulness of the developed program.

  • PDF

Excess Flow Valves for Underground Gas Pipeline and their Performance Testing Equipment Development (연료가스 매몰배관용 과류차단밸브와 성능시험 장치 개발)

  • Lee, Ugwiyeon;Joo, Yukyung;Lee, Jinhan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.74-81
    • /
    • 2018
  • The Korean Government has proceeded petroleum gas pipeline construction business since 2014 for rural districts. The operating pressure of petroleum gas pipeline are from 25kPa to 75kPa which are different from that of natural gas pipeline. Petroleum gas pipeline pressure is ten or forty times higher than natural gas operating pressure. For this reason, petroleum gas pipeline has higher probability of accident occurrence from massive gas leakage. Korea Gas Safety Corporation begins to development excess flow valves and their performance testing equipment since 2017. The excess flow valves stop the gas flow when a overflow happened in gas pipeline. The excess flow valves are generally not installed in main pipeline, because that may block massive gas supply. So, the valves are installed in starting points of branch pipes. According to the number of house and amount of gas use, a shut-off point of exxcess flow valve is determined called as Trip Flow. The trip point is the most important thing of excess flow valve, so, it is required a equipment testing the performances of excess flow valve as trip point.

Measures to Secure Safety according to Gas pipe Hydrogen Mixing(Carbon Neutral) (가스배관 수소혼입(탄소중립)에 따른 안전확보 방안)

  • Kwak, Che-Sik;Sin, Dong-Il
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.290-291
    • /
    • 2022
  • 본 논문에서는 우리나라 2030년 국가 온실가스 감축목표(NDC*, 291백만톤 감축)달성 및 2050년 탄소중립 목표 달성을 위해 필연적으로 수반되는 천연가스 내 수소 혼입에 따른 안전성확보 방안과 수소혼입에 따른 국민 불안감 해소 및 수용성 제고를 위한 대안을 제시하고, 해외 사례를 연구 하였다. 탄소중립은 온실가스(이산화탄소 등)의 배출량을 최대한 줄이고, 남은 온실가스를 흡수, 제거해서 실질적인 배출량이 "0"이 되는 것을 의미하고, 수소혼입은 도시가스의 주성분인 메탄 연소시 발생하는 CO2를 최소화하기 위해 수소(H2)를 도시가스에 일정비율 혼합하는 것을 말한다. 본 연구에서는 수소 혼입 시 우려되는 수소취성 및 배관내구성 문제와 수소 특성인 작은 입자로 인한 누출 위험성, 고층에서 메탄과 수소가 분리되는 현상 등에 따른 문제를 도출하고 이에 대한 안전관리 방안도 함께 제시하였다. 또한, 도시가스 배관에 수소 혼입시 천연가스 대체를 통한 온실가스 감축 및 기존 배관망 사용을 통한 경제성 분석결과와 국가 온실가스 감축에 어느 정도 기영할 수 있는지도 함께 기술하였다.

  • PDF

A Study on the Safety Management of High Pressure Underground Pipeline in Industrial estate (산업단지 고압매설배관 안전관리 고찰)

  • Choi, Hyun-Woong;Chung, Se-Kwang;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.30-38
    • /
    • 2017
  • Established in the 1960s, high pressure underground pipelines in Ulsan and Yeosu industrial estate are underground as toxic gas as well as combustible gas that is heavier than city gas and low combustion range. Especially, industrial pipelines occupy more than 20 years old pipes. In this way, the industrial estate pipeline was installed before the introduction of the supervision of construction, However, unlike the city gas pipeline, the pipeline is managed without any legal obligation. In this study, the safety management status of high pressure underground pipelines and urban gas underground pipelines in the industrial estate is analyzed and comparison of laws, extent of damage impact, using the pipe inspection model for pipe inspection of high pressure piping system with the existing piping system. it is intended to cuntribute to improving the safety of industrial estate are underground pipeline.

An Experimental Study on Detection of Gas Leakage Position by Monitoring Pressure Values at City Gas Pipeline (압력값 모니터링을 통한 배관 내 가스누출감지에 대한 실험적 연구)

  • Jin, Kyoung-Min;Choi, Gyu-Hong;Lee, Song-Kyu;Chung, Tae-Yong;Shin, Dong-Hoon;Hwang, Seung-Sik;Oh, Jeong-Seok
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.292-297
    • /
    • 2011
  • Gas pipeline safety management and risk prediction are recognized as a very important issue. And the effort to prevent accidents is essential. So, in this study, it was studied through correlation of pressure changes for leak point detection in real-time. It experimented by installing the five leakage valves in the pipe of 378 m and compared the actual leak points with simulation results. The results showed that experimental leak points and the actual leak points have differences within the 6 m. And this technology has to be commercialized by the demonstration in dangerous zone.

Malfunction Analysis when a EFV is Working (과류차단 밸브 작동 시 오작동에 대한 분석)

  • Jeon, Hyung Taek;Park, Sung Jin;Kim, Sung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.28-33
    • /
    • 2018
  • Currently, the government has been expanding the supply of semi-low-pressure in order to solve the problems of unsupplied area of city gas and to secure the economical efficiency of small supplied area. It is mainly supplied from the central storage tank to each household by buried piping. It is necessary to provide such a shutoff valve that can block the excess flow gas due to pipeline leak or rupture when piping is damaged by other construction. For this study, System CFD code named Flownex has been used and a component corresponding to the actual EFV was developed. We compared Flownex results with experimental data to verify the accuracy of Flownex and confirmed the error rate to be around 2%. In this study, pipeline network modeling was done by selecting the LPG supply pipeline in a village and installed the component of the EFV at each junction. We selected the longest pipeline from the main pipeline and set scenarios so that the excess flow occurs by that the pipeline is ruptured before entering the household. The excess flow occurs by the pipeline rupture and the EFV is closed. At this time, we analyzed backflow effects to the other pipeline by closing EFV.

Development of Performance Test Procedure for the Excess Flow Valve for Buried Piping for the Domestic LPG Mass Supply System (국내 LPG 집단공급시설 환경에 적합한 매몰배관용 과류차단밸브 성능시험 절차 개발)

  • Jang, Chanyeong;Lee, Ugwiyeon;Lee, Jinhan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.16-27
    • /
    • 2018
  • Since 2014, the Korean government has begun distributing LPG pipelines and LPG tankers to mountainous or island areas where it is difficult to open urban gas supply chains. When installing LPG supply facilities at village level and county level, it supplied consumers with 10 times higher quasi-low pressure (25 kPa to 100 kPa) than conventional gas supply pressure, increasing the risk of gas accident. Due to the pressure that is 10 times higher than the conventional gas supply pressure, large amounts of gas are released at a faster rate when leaked. In order to secure safety of quasi-low-pressure gas pipes, excess flow valves for quasi-low-pressure gas pipes are not developed and are not supplied in Korea. Therefore, Korea Gas Safety Corporation is investigating the performance standards and products of the excess flow valves in order to localize the excess flow valves.

Forecasting Hourly Demand of City Gas in Korea (국내 도시가스의 시간대별 수요 예측)

  • Han, Jung-Hee;Lee, Geun-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • This study examined the characteristics of the hourly demand of city gas in Korea and proposed multiple regression models to obtain precise estimates of the hourly demand of city gas. Forecasting the hourly demand of city gas with accuracy is essential in terms of safety and cost. If underestimated, the pipeline pressure needs to be increased sharply to meet the demand, when safety matters. In the opposite case, unnecessary inventory and operation costs are incurred. Data analysis showed that the hourly demand of city gas has a very high autocorrelation and that the 24-hour demand pattern of a day follows the previous 24-hour demand pattern of the same day. That is, there is a weekly cycle pattern. In addition, some conditions that temperature affects the hourly demand level were found. That is, the absolute value of the correlation coefficient between the hourly demand and temperature is about 0.853 on average, while the absolute value of the correlation coefficient on a specific day improves to 0.861 at worst and 0.965 at best. Based on this analysis, this paper proposes a multiple regression model incorporating the hourly demand ahead of 24 hours and the hourly demand ahead of 168 hours, and another multiple regression model with temperature as an additional independent variable. To show the performance of the proposed models, computational experiments were carried out using real data of the domestic city gas demand from 2009 to 2013. The test results showed that the first regression model exhibits a forecasting accuracy of MAPE (Mean Absolute Percentage Error) around 4.5% over the past five years from 2009 to 2013, while the second regression model exhibits 5.13% of MAPE for the same period.

An International Comparison of Industrial Organization and Regulation Trends in the Gas Sector (가스산업 조직 및 규제 동향의 국제비교)

  • 남궁윤;박연홍;최성수;김경식
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.93-107
    • /
    • 1996
  • Six countries are considered in the study for the comparison of their respective gas industries with the Korean gas industry: the U.S., Canada, the U.K., France, Germany and Japan. The emphases of comparison are given on the cross-evaluation of industry organizations and related regulations. In terms of industrial development stages, the Korean gas industry, with its short experience and in need of more infrastructure, is still young and at an early stage of development. Due to this reason, the study finds that it is premature for the Korean case to propose some policies like the promotion of competition in the gas transportation through third-party access to pipelines. or seeking overseas business opportunities requiring venture capital and advanced technology. Recommendations are made that Korea rather, for the time being, concentrate its energy on the construction of infrastructure and on securing supply sources and diversifying import origins, in order to strengthen it's supply capability in the face of rapidly increasing gas demand in the nation. Nevertheless, Korea will soon have to consider more seriously about the deregulation of the market and more diversified business activities through the development of high technology and managerial skills.

  • PDF