• Title/Summary/Keyword: 도막성능

Search Result 83, Processing Time 0.024 seconds

A Study on the Field Application Analysis for High Adhesive Spray Type of Degenerated and Rubberized Asphalt Membrane Material (스프레이식 고점착 변성 고무 아스팔트 도막 방수재의 현장 적용성 평가에 관한 실험적 연구)

  • Oh, Sang-Keun;Kwak, Kyu-Sung;Choi, Sung-Min;Song, Je-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.4 s.22
    • /
    • pp.85-92
    • /
    • 2006
  • Urethane, epoxy, acrylic have common property to adhere on the concrete dried surface in the waterproofing materials at present. In the wet condition, however, the materials such as urethane, epoxy, acrylic need a long hardening time and it become a reason of water leakage as the materials breaking down. it is one of the problem to adhere to the substrate. Therefore, in this thesis, I focused to assure the structural safety and durability and quality for waterproofing and safe of construction cost by cut down the cost of labor and reduce the term of works as searching the application of field condition for high adhesive spray type of degenerated and rubberized asphalt membrane material.

Synthesis of Dialcrylate Bearing Biphenyl Moiety and Photopolymerization Behavior (Biphenyl moiety를 가진 diacrylate의 합성 및 광중합 거동에 관한 연구)

  • 배정환;최명수;김환건;권영돈;이준영
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.364-367
    • /
    • 2001
  • lithography를 사용하여 패턴 형성에 이용되는 감광성 고분자 바인더 수지로는 통상 아크릴수지 또는 폴리이미드 수지가 사용된다. 폴리이미드 수지는 양호한 성능을 나타내지만 패턴 형성에 난점이 있다. 반면 아크릴수지는 패턴현상성은 우수하지만, 내열성능이 폴리이미드 수지보다는 낮기 때문에 고온 고습하에 기판을 장시간 방치한 경우, 화소내 도막의 변색이나 중량감소 등 여러 문제가 생길 수 있다. (중략)

  • PDF

Airtightness performance evaluation of ultra-high performance concrete using polymer coating materials (그래핀을 활용한 폴리머 도막재료의 물리적 특성 평가)

  • Lee, Hyun Seung;Kim, Kang Min;Yoon, Seob;Seo, Tae Suk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.257-258
    • /
    • 2023
  • In this study, it was conducted to improve the physical properties of VAE polymer matrix used as a coating material. A nanocomposite was manufactured using graphene as a reinforcing agent based on a VAE matrix. As a result, improvements in tensile strength, adhesion strength, and porosity were confirmed.

  • PDF

An Experimental Study about appling non-Exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Self adhesive Rubberized Asphalt sheet to the Roof Structure. (무기질계 탄성 도막재와 자착식 고무 아스팔트 시트를 결합한 지붕구조물 비노출 방수공법에 관한 실험적 연구)

  • Moon, You-Seok;Lee, Sun-Gyu;Song, Je-Yeong;Gwak, Gyu-Seong;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.613-616
    • /
    • 2008
  • This study is about appling non-exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Selfadhesive Rubberized Asphalt sheet to the Roof Structure, Because there are a lot of problems in previous methods. So We had the performance tests using waterproofing method which combines two materials, and we analyzed the results. This study showed us very important results. We had bond strength test and tensile test under high, normal and low temperature, and the results were successful. And we also tested for coping with crack and movement. We found that tested materials were safe in those conditions. I think that Non-Exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Selfadhesive Rubberized Asphalt sheet is available to concrete structure.

  • PDF

A Study on Property with Ratio of Water Mixture in Hydroponic Polyurethane Waterproofing Materials (수경화성 폴리우레탄 도막 방수재의 물 혼합비에 따른 물성변화연구)

  • Park, Jin-Sang;Park, Wan-Goo;Kim, Dong-Bum;Lee, Min-Kyu;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.4
    • /
    • pp.348-354
    • /
    • 2015
  • Urethane waterproofing materials which currently being used most commonly in the Korean domestic market have high applicability and construct layers without forming any joints, but under the influence of low temperature and low humidity, as well as the thickness of the applied layer, the curing time of this material may become extended in construction sites. To resolve these issues, a proposed method of using water-hardening type of polyurethane waterproofing materials are being developed. However, there currently lacks any standards or evaluation methods on determining an optimal mixture ratio of water for the water-hardening polyurethane waterproofing materials. Therefore, workers and construction workers are relying on their hands-on-skills and experience to determine this ratio and are not able to obtain a consistent performance quality out of these materials. Therefore, for the establishment of a board applicability of the water-hardening polyurethane waterproofing methods in construction sites, this study objectively analyzes the changes in the performance of these materials depending on the changes of the water mixture ratio and attempts to procure the optimal ratio on the basis of forming a provisionary standard. The study prepares mixtures of varying ratio(no water added, 5, 10, 15, 20, 25, 30, 40 and 50) and conducts comparative analysis respective mixtures' performances and their changes in the physical properties in an objective manner and proposes a provisional optimal value that can serve as a data base that can be used as a reference for future studies.

Enhancing Construction Productivity and Quality Through Waterproofing Equipment Technologies (생산성 및 품질향상을 위한 방수공사의 장비 활용 시공기술)

  • Kim, Han-Sic;Ha, Jung-Soo;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.4
    • /
    • pp.429-440
    • /
    • 2023
  • This research investigates the deployment of waterproofing technologies in construction, with a specific focus on augmenting worker safety, work environment, and solve the difficulty of securing skilled workers. Implementing liquid waterproofing cement equipment resulted in a remarkable increase in adhesion performance by around 20%, coupled with a twofold acceleration in operational speed. The application of primer spraying apparatus led to a two-fold improvement in both penetration and adhesion performance, concurrently boosting the work speed by approximately the same factor. With urethane spraying equipment, the workload could be reduced to a third for the same layer thickness, adhesion performance enhanced by approximately 1.4 times, and workability improved by about 1.4 to 1.5 times. These findings suggest that such technological interventions can potentially enhance work efficiency, improve the quality of output, and mitigate safety accidents that are commonplace in manual operations. Furthermore, these advancements present promising solutions to the ongoing challenges of sourcing highly-competent workers in the industry.

Performance Analysis for Proposing Proper Construction Method for Joints of Polyurea Waterproofing Membrane Coating (폴리우레아 도막방수재의 이음부 적정 시공안 제안을 위한 성능 분석)

  • Lee, Jung-Hun;Kim, Byoungil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.77-86
    • /
    • 2024
  • In this study, an evaluation was conducted for a total of 16 conditions to suggest an appropriate construction method for the construction joint of polyurea waterproofing membrane coating. It was analyzed that the longer the construction time difference, the higher the rate of water leaks through joints, and it was confirmed that water leaks could be prevented through primer construction. In addition, since the surface of polyurea exposed outdoors for a long period of time is deteriorated and weakened, it was analyzed that polishing the area increases surface damage and affects the formation of the interface. During maintenance construction, it would be desirable to apply a primer before construction, and it is believed that using the same urea-based material will ensure waterproofing stability.

A Study on the Defect Causes Type for Poly-Urethane Waterproofing in Roof (옥상 방수에 있어서 폴리우레탄 도막방수의 하자발생 유형에 관한 연구)

  • Shin, Hyung-John
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.3 s.25
    • /
    • pp.128-134
    • /
    • 2005
  • Up to now, the various water proofing methods and materials have been developed. For the water proofing methods, poly-urethane membrane method is one of the commonly used and increase market share in water proofing industry due to it's many advantages. However, in spite of it's many advantages over other water proofing methods, water proofing defect occurs frequently. With this respect, the study investigate water proofing defect causes in roof water proofing. The study investigate 13 water proofing construction site in Sunchon city in oder to find urethane membrane defection causes and their type. As a results of the study, the followings are founded. 1) Among various water proofing defection causes, problems of water remain phenomenon due to surface horizontal level defect which occupy $25\;\%$ of total defect causes is the most commonly occur. 2) The second defect cause which occupy $15\;\%$ of total defect causes is the swell up phenomenon due to surface dry problem. For the prevention of water proofing defection in roof using urethane membrane, the followings are recommended. 1) Faultless surface treatment before using urethane membrane 2) Develop improved urethane membrane material 3) Improve urethane membrane construction technique

Experimental Study of Bond Properties Using Coated Bars (도막재료에 따른 철근의 부착성능에 관한 실험적 고찰)

  • 김영진
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.211-216
    • /
    • 2003
  • Coated bars are protecting reinforcing bars from corrosion and enhancing durabilities of reinforced concrete structures are tested to evaluate corrosion protection properties. Tests are performed based on the relevant standards of ACI and ASTM, such as chemical resistance, salt water spray, salt crack test and chloride permeability test with the main variable of the coating thickness. Three type materials are tested by Polyethylene, epoxy and bare bar. Test results show good chemical protection property and chloride permeability. Polyethylene coated bar is good coating material than any other materials.

  • PDF

Effect of chemical etchant on the material properties of ZnO:Al front electrodes and the cell performance of silicon thin film solar cells (화학적 식각조건에 따른 ZnO:Al 투명전도막 특성분석 및 실리콘 박막 태양전지 효율변화 연구)

  • Kim, JungJin;Cho, Jun-Sik;Lee, Ji Eun;Jang, Ji Hun;Cho, Yong Soo;Park, Joo Hyung;Song, Jinsoo;Lee, Jeong Chul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.130.2-130.2
    • /
    • 2011
  • 본 연구에서는 RF magnetron sputtering을 이용하여 실리콘 박막 태양전지용 ZnO:Al 전면전극을 제작하고 다양한 식각조건에 따른 ZnO:Al 박막의 표면형상 변화와 함께 전기적 및 광학적 특성 변화를 조사하였다. pin 구조를 갖는 실리콘 박막 태양전지의 효율 향상을 위해서는 입사광의 산란효과에 따른 광포획 증가가 필수적이며 이를 위하여 ZnO:Al 전면전극의 표면텍스처링 형성이 필요하다. 식각용액으로는 HCl과 HF 등을 사용하였으며 식각용액 농도 및 식각시간을 변화시켰다. 식각 후의 ZnO:Al 박막의 표면형상은 SEM(Scanning Electron Microscope)과 AFM(Atomic Force Microscope)을 이용하여 분석을 하였고, UV-visible-nIR spectrometer를 이용하여 총 투과도 및 산란 투과도를 측정하였다. 이 외에도 four-point probe 및 Hall measurement를 이용하여 전기적 특성 변화를 조사하였다. 다양한 식각조건에 따라 제조된 ZnO:Al 박막 위에 실리콘 박막 태양전지를 제작하여 전면전극의 표면형상에 따른 태양전지 성능변화를 비교 분석하였다.

  • PDF