• Title/Summary/Keyword: 데크 플레이트 두께

Search Result 28, Processing Time 0.02 seconds

An Experimental Study on the Flexural Behavior of Deck Plates with Metal Lath and Mortar (라스와 모르타르를 이용한 데크의 휨거동에 관한 실험적 연구)

  • Kim, Sung-Bae;Kim, Sung-Jin;Seo, Dong-Min;Kim, Sang-Seup
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.117-125
    • /
    • 2008
  • In the domestic construction industry field nowadays, the usage of deck plates is currently increasing due to the lack of construction workers and the rised in construction cost. However, using deck plates manufactured by thin zinc galvanization in underground structures is criticised because it can lead to increase in maintenance cost caused by rust generation and water leakage. As a solution for this particular problem, deck plates created by Lath and Mortar instead of zinc galvanized steel sheets were developed. This paper deals with the experimental study on flexural behavior of deck plate using metal lath and mortar. Seventeen fullscale specimens were constructed and tested with different type of truss, the diameter of the top and bottom bar, and the thickness of slab. Tests results show that LAMO deck displayed equal performance such as zinc galvanized steel sheets.

Development of Steel Wire-Integrated Deck Plate Applicable to Slab with 180mm Thickness (두께 180mm 슬래브에 적용 가능한 철선일체형 데크 플레이트 개발)

  • Lee, Yong Jae;Yoon, Sang Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.89-98
    • /
    • 2012
  • A steel wire-integrated deck plate that welds integrated triangle truss steel wires on a galvanized steel sheet is developed to reduce construction costs of slabs or formworks such as shores and supports, and it is already widely applied in many construction fields. In this research, experimental tests for 14 full scale specimens, which are in the same field conditions, are conducted on several parameters such as the diameter of top, bottom and lattice steel wire, cutting methods of ends. According to the result, changes in final destruction types of the test bodies and cutting methods of ends didn't affect structural performance of test specimens, and for a 4.0m-span test specimen, there was no big problems in using bottom bar D7 or D8.

An Experimantal Study on the Flexible Capacity of New Shape Flat Deck Plate(ACE-DECK) for Using Composite Slabs Systems. (신형상의 합성용 평데크플래이트(ACE-DECk)의 휨성능에 대한 실험적 연구)

  • Oh, Sang-Hoon;Jang, In-wha;Bae, Kyu-woong;Heo, Byung-wook;Yang, Myung-sook
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.3
    • /
    • pp.265-277
    • /
    • 2001
  • This paper present a study on the flexural behavior of composite slabs using the flat-type profiled(ACE-DECK) steel deck plate which are developed recently. Forty eight composite slabs with different thickness, span, shear span and deck profile were tested to evaluate the flexural capacity and compared to the existing traperzodial deck profiles (KEM, ALPHA-DECK) According to the experiment results, flat-type profiled steel deck plate indicates more excellent capacity than existing traperzodial deck profiles in strength, stiffness, and ductility. The equation proposed by ASCE code for the effective moment of inertia are more acceptable than the equation proposed by ACI code. Thus, in this paper, test results are summarized by strength, stiffness, and deformation capacity for the specimens.

  • PDF

An Experimental Study on the Flexural Behavior for the Slabs using the Suspending Deck plate (매닮 데크플레이트를 이용한 슬래브의 휨거동에 관한 연구)

  • Bae, Kyu Woong;Lee, Sang Sup;Park, Keum Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.25-34
    • /
    • 2013
  • The purpose of the this paper is experimentally to investigate flexural behavior of slabs with suspending the deck plate. The main experimental parameters are the depth and thickness of the deck plate, slab span, rebar and support conditions. Total number of six specimens were tested and manufactured in slabs under vertical load. Based on the results of the test, the flexural behavior for slabs is determined according to the vertical deformation of the slabs, regardless of the main experimental parameters. Bending rebar reinforcement in the rib cross-section specimens can be evaluated significantly higher initial stiffness, crack stiffness and flexural strength. Result of the comparison of the theory value appeared to be fairly well matched to average 1.05.

Analytical Study on the Development of High-Performance Orthotropic Steel Deck considered the Fatigue Behaviors of Structural Details (구조 상세부의 피로거동을 고려한 고성능 강바닥판 개발에 관한 해석적 연구)

  • Kyung, Kab Soo;Shin, Dong Ho;Kim, Kyo Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.4
    • /
    • pp.417-426
    • /
    • 2006
  • Various fatigue damages have been reported in orthotropic steel deck structures put upon girders. These damages are caused by complex behaviors of the deck, which is directly subjected to vehicle loads. To estimate the causes of fatigue cracks at the welded connected parts of the trough rib and the flor beam, and the trough rib and the deck plate, in orthotropic steel deck structures, FE analyses were first, performed in this study. Parameter studies were carried out to suggest effective structural details that consider fatigue, in which the main parameters are the thickness of the deck plate, the shape of the connection of the trough rib and the flor beam such as the slit form, and the welding length. This study suggests that the effective structural details improved the fatigue strength and discusses.

Long-term Behavior of Deck-plate Concrete Slab Reinforced with Steel Fiber (강섬유 보강 데크플레이트 콘크리트 슬래브의 장기 거동)

  • Hong, Geon-Ho;Hwang, Seung-Koo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.30-38
    • /
    • 2017
  • Recently, research on the development of a composite slab system for shorting the construction period by simplifying the process by omitting the form work and the reinforcement placing is underway. The purpose of this study is to evaluate the long-term behavior of a simplified slab system that replaces the form work and tensile reinforcement using structural deck-plate and replaces the temperature reinforcement using steel fiber reinforced concrete. In the conventional composite deck-plate slab method, w.w.f is generally used for crack control by drying shrinkage. But previous research results by various researchers were pointed out it is not effective to control the shrinkage and temperature cracking. In this study, the long-term cracking and structural behavior of steel fiber reinforced deck plate slab specimen with two continuous spans constructed under typical load conditions were evaluated. Experimental results showed that the number and width of long-term cracks decreased remarkably in the simplified slab specimen, and the deflection was also decreased compared with conventional RC slab specimen. However, in the continuous end of the slab where the negative moment is applied, it is analyzed that reinforced details are necessary to control the crack width in the service load and to recover deflection at load removal.

Improvement of Flexural Performance for Deep-Deck Plate using Cap Plate (캡플레이트를 이용한 장스팬용 춤이 깊은 데크의 휨성능 개선)

  • Park, K.Y.;Nam, Y.S.;Choi, Y.H.;Kim, Y.H.;Choi, S.M.
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.555-567
    • /
    • 2013
  • Slim floor system using deep decks has been developed and employed in Europe to reduce the floor height of steel structures. Although long span buildings involving the issue of reducing floor height are being increasingly built in Korea, employing deep decks in more than 7m long span structures is likely to cause problems associated with excessive deflection. This study is applied to the long-span concrete casting of the deep deck plate usability of deflection due to bending and torsional instability of open cross-section, as a way to improve the problem of cap plates are suggested, and the optimum length of reinforcement and location are derived from theoretic estimation. The cap plates are placed on the deep decks with regular intervals to overcome the instability of open sections, improve the stiffness of the sections and control the deflection at the centers. The improvement in flexural capacity associated with the location of the cap plates and the length of reinforcement are verified through analysis and test.

A Study of Structural Performance of Self-Drilling Screw Connections (직결나사 연결 접합부에 관한 구조성능평가 연구)

  • Park, K.Y.;Jeon, S.H.;Kim, Y.H.;Choi, S.M.
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.543-553
    • /
    • 2013
  • As the deep deck plate has the shape of open cross section, It can cause structural problems such as bending torsions due to instability of the section. There are a number of fasteners types which are frequently used on light gage steel diaphragms such as bolts, rivets, welds, and screws. In this study, the structural capacity of the self drilling screw connection between the deep deck and the reinforced cap plate was evaluated by experimental variables such as the arrangement method, numbers of screw, pitch of screw, and head plate thickness.

Structural Performance of Double Rip Decks Reinforced with Inverted Triangular Truss Girders (역삼각 트러스 거더로 보강된 더블 골 데크 성능 평가)

  • Son, Hong-Jun;Kim, Young-Ho;Chung, Kyung-Soo;Kim, Dae-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.559-566
    • /
    • 2017
  • This paper proposes a new composite deckplate system reinforced with inverted triangular truss girders(called 'D Deck'), which does not require the use of temporary supports at construction stage. The proposed system retains increased stiffness and strength while keeping the absolute floor height change to a minimum level and can be utilized as floor systems of various types beam members such as the conventional wide-flange and U-shaped composite beams. In order to evaluate the performance of the proposed system, five specimens with a span of 5.5 m were fabricated and tested under field loading conditions consisting of several intermediate steps. The load-deflection curves of each specimen were plotted and compared with the nonlinear three-dimensional finite element analysis results. The comparison showed that the effective load sharing between the truss girders and floor deck occurs and the maximum deflection under construction stage loading is well below the limit estimated by the provisions in Korea Building Code.

A Study on Structural Behavior of Composite Deck Plate using a Pre-assembled Re-bar Truss (철근 선조립형 복합 데크플레이트의 하부근 선경축소에 따른 구조적 거동 평가)

  • Yoo, Byung-Uk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.129-138
    • /
    • 2006
  • Composite deck plate using a pre-assembled re-bar truss for slab with corrugated zinc galvanized sheet iron at manufactory, is given the improvement on design, manufacture, and performance for construction work of cast-in-place reinforced concrete slab by enabling to cast concrete directly without the form work. There are two methods in analyzing composite deck : Simplified 2D analysis and 3D analysis. Although simplified 2D analysis is being used up to date, the use of 3D analysis, allowing for the vierendeel behavior of composite deck by real configuration correlating to bar reducing, is demanded. To compare the simplified 2D analysis applied to allowable stress design with 3D analysis applied to limit state design, 8 specimen are manufactured. Main variables include the depth of slab, the length of span, the diameter of bottom bar and lattice bar, and the presence of corrugated zinc galvanized sheet iron. The comparison from the experimental result and analytical result indicates that applying of simplified 2D analysis is possible for the use of D10 with bottom bar. However, it is more reasonable to apply 3D analysis which allows to indicate vierendeel behavior considered the real configuration.