• Title/Summary/Keyword: 대형 시험

Search Result 896, Processing Time 0.021 seconds

Design of a Planar Log-Spiral Antenna for Testing Plane-Wave Shielding Effectiveness (평면파 차폐효과 시험용 평판형 로그 스파이럴 안테나 설계)

  • Chung, Yeon-Choon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.762-767
    • /
    • 2019
  • The plane-wave shielding effectiveness is typically measured for horizontal and vertical polarizations using a linearly polarized antenna. However, this typical measurement method results in big evaluation fees due to very long measurement time as well as huge idle space for maintenance, these problems is more severe especially in large shielded enclosures such as EMP protection facilities to be built in indoor buildings and underground. This paper describes the design and fabrication process and results of a planar log-spiral antenna applicable to the evaluation of the electromagnetic shielding effectiveness of a large EMP protection facility. Since the proposed antenna has a circular polarization, there is no need to separately measure the horizontal and vertical polarizations. Therefore, the measurement time can be shortened by more than 1/2, and further, its small volume with a planar structure can reduce greatly idle space required for the maintenance.

Stability analysis of shield tunnel segment lining by field measurement and full scale bending test (실대형 하중재하 시험 및 현장계측을 통한 쉴드터널 세그먼트 안정성 분석)

  • Lee, Gyu-Phil;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.611-620
    • /
    • 2019
  • The shield tunnel was mostly applied to cable tunnel with a diameter of 3~4 m, recently 7.8 m diameter shield tunnel was constructed in the lower section of the Incheon International Airport runway and is planning or under construction to roads and railway tunnels in the lower section of the Han River. Segments are also becoming larger as the shield tunnel cross-section increases, which causes a number of problems in the design, construction, and performance evaluation of segments. In this study, segment lining structural safety, criteria for serviceability check considering axial forces and quality control method for approximately 8 m in diameter shield tunnel were reviewed by field measurements and full scale bending test.

Study of the Open-Water Test and Analysis for a Pumpjet Propulsor in LCT (대형 캐비테이션터널에서 펌프젯 추진기 단독성능 시험 및 해석 기법 연구)

  • Ahn, Jong-Woo;Seol, Han-Shin;Jung, Hong-Seok;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.3
    • /
    • pp.149-156
    • /
    • 2022
  • In order to study the open-water test and analysis techniques for pumpjet propulsors in the Large Cavitation Tunnel (LCT), at the Korea Research Institute of Ships and Ocean Engineering, a set of test equipment was designed and manufactured. The pumpjet propulsor is composed of rotor, stator and duct resulting in the strong interaction between the components. A ring-shaped sensor was developed to measure the thrust and torque for duct and stator. The test equipment including the pumpjet is installed on an existing POW dynamometer in the reverse direction. The results from the reverse POW test setup were validated against those from the conventional POW test setup in the Towing Tank (TT) as well as in the LCT. The pumpjet open-water test was conducted at the Reynolds number of around 1.0×106, at which the obtained experimental data became stable in the Reynolds number effect test. The open-water test for the rotor (rotor-only) was conducted to study whether the duct and stator should be considered as a part of the hull or the propulsor. On the basis of the test results, it was shown that the duct and stator could be included in the propulsor. The total thrust, combined thrust of rotor, duct, and stator was used for the pumpjet open-water test analysis. As the whole pumpjet is defined as a propulsor, it is thought that the self-propulsion test and analysis could be conducted in the same way as that of the conventional propeller.

A Study on the Calculation of Minimum Safety Distance during Storage and Combustion Test of Solid Propellants for Launch Vehicles (발사체 고체추진제의 저장 및 시험 시 안전거리 산정에 관한 연구)

  • Shin, Ahn-Tae;Park, Byung-Mun;Byun, Hun-Soo
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.180-185
    • /
    • 2021
  • In accordance with the revision of the US-Korea missile guidelines, restrictions on the use of solid propellants for space launch vehicles have been completely lifted. The solid propellant can be used as a solid propellant rocket like the KSR-1 (Korea Sounding Rocket-1), and can also be used as a thrust augmentation booster for liquid fuel launch vehicles. It is known that solid propellants have a lower risk of explosion than liquid propellants. but if an accident such as an explosion at the Alcantara Launch Center in Brazil occurs, it can lead to a large-scale personal accident. In order to prevent such large-scale accidents, it is necessary to review and reflect the minimum safety distance during use, storage and combustion test of solid propellants from the planning phase of the project. In this paper, the minimum safety distance for safe use of the solid propellant is presented by dividing it into storage facilities and combustion tests.

Evaluation of Load Transfer Characteristics of Barrette Pile Based on Bi-directional Loading Tests (양방향 재하시험결과를 활용한 바렛말뚝의 하중전이특성 평가)

  • Park, Seong Wan;Lim, Dae Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2C
    • /
    • pp.41-49
    • /
    • 2009
  • Due to the increased size of civil infrastructure and the cost of materials, the needs exists for utilizing large sized cast-inplace piles in lieu of conventional precast piles. Among them, the barrette pile has become more commonly used in fields where a diaphragm wall is the retaining wall, to improve workability and economical efficiency, and to ensure hole stability under deep soil layers. In this paper, the bearing capacity and displacement characteristics of the barrette pile are evaluated by using the bi-directional loading test data obtained from four different sites. In addition, the design value of pile shaft resistance, ${\beta}$, is assessed with previous literatures and load transfer analysis. Finally, numerical analyses were performed to analyze the load-displacement behavior, and the interface effect on the piles, using the 3-dimensional finite element method.

Spatial Variation of Void Ratio and Permeability by Smear and Its Changing Behavior during Consolidation :Part I. Physical Model Test and Analysis (스미어로 의한 점성토 지반의 간극비 및 투수계수의 위치별 차이와 압밀 중 변화 거동에 대한 연구 : Part I. 실험 및 거동 분석)

  • Yune, Chan-Young;Son, Dae Jin;Chun, Sung-Ho;Chung, Choong-Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4C
    • /
    • pp.137-144
    • /
    • 2009
  • In this research, the ground with smeared zone was reconstructed using the large consolidation test apparatus. And the reconstituted kaolinite samples at different locations were retrieved for the oedometer test. From the oedometer test results the permeability- void ratio-effective stress behavior was investigated. Based on the experimental analysis, spatial differences of permeability according to the drainage distance by both smear and radial drainage consolidation reduced as the consolidation proceeds and eventually disappeared in normally consolidated region. And the spatial variation of permeability by radial drainage consolidation showed larger differences in smaller extent than the spatial variation of permeability by smear.

Electromagnetic Environment Analysis of Goheung Aviation Center (고흥항공센터의 전기장 환경 분석)

  • Jang, Kyung-Duk;Kim, Tae-Youn;Jang, Jae-Woong;Min, Byong-Hee;Cho, In-Kyoung;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.46-53
    • /
    • 2013
  • In this study, the analysis of electromagnetic environment of goheung aviation center was performed. If the test object has restrictions to be tested in indoor test facility, open area test site can be used to perform EMC test. Open area test site shall have no obstacles that can generate or reflect the electric field so as to prevent the measurement result from being influenced by unnecessary field. Goheung aviation center is surrounded by fields, and has no buildings that can reflect electric field, so the center can be a good candidate for open area test site. Ambient noise at Goheung aviation center was measured, and the result show that the center has good electromagnetic environment to perform EMC test for large volume object.

Thermal Shroud Design of a Large Space Simulator(${\Phi}8m{\times}L10m$) (대형우주모사장비(${\Phi}8m{\times}L10m$) 열교환 슈라우드 설계)

  • Cho, Hyok-Jin;Moon, Guee-Won;Lee, Sang-Hoon;Seo, Hee-Jun;Winter, Calvin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1236-1240
    • /
    • 2004
  • Thermal vacuum test for satellites should be performed before launch to verify the feasibility of satellites' operation in a harsh space environment which is represented as an extremely cold temperature and vacuum condition. A large space simulator(${\Phi}8m{\times}L10m$) has been demanded to accomplish the thermal vacuum test for the huge satellites designed in compliance with the national space program of Korea. In this paper, the design and calculation of thermal shroud which is the core part of large space simulator were discussed. The characteristics of the large space simulator being constructed at Korea Aerospace Research Institute(KARI) were depicted.

  • PDF

experimental Investigation of Noise and Vibration Phenomena of a Heavy-duty Truck at High-Speed Driving (대형트럭의 고속 주행시 진동소음 현상에 관한 실험적 연구)

  • Lee, Yang-Sup;Han, Moon-Sik;Cho, Hang-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.6
    • /
    • pp.77-82
    • /
    • 1999
  • 대형 화물트럭의 차실 내에 높은 수준의 차바닥 진동을 수반한 높은 소음이 발생하였다. 측정 및 분석결과 문제의 진동 소음은 추진축의 회전 1차 및 2차 성분으로 나타났다. 진동 전달경로상의 구성계 및 구성요소들에 대해 모드해석과 실차 주행 모드 해석시험을 실시한 결과 드라이브라인 및 프레임의 공진주파수가 문제가 되는 소음진동 주파수와 거의 일치하였으며, 또한 캡의 실내음향 공진 모드가 문제되는 주파수에서 존재하였다. 실험결과에 따라 액슬과 액슬간의 축의 장착각도를 변경하여 가진력을 줄이고, 비틀림 동흡진기를 추진축에 장착하여 드라이브라인계 공진을 제어함으로써 문제의 시내진동소음을 현저히 개선하였다.

  • PDF

Modal Test of the 2nd stage structure of KSLV-I (KSLV-I 2단부 구조체 모드 시험)

  • Seo, Sang-Hyeon;Jeong, Ho-Kyeong;Youn, Se-Hyun;Park, Soon-Hong;Jang, Young-Soon
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.114-119
    • /
    • 2007
  • This paper introduces modal test of the 2nd stage structure of KSLV-I which is composed to satellite, PLA(Payload Adapter), EB(Equipment Bay), KMS(Kick Motor Support) and KM(Kick Motor) without PLF(Payload Fairing). In this test, to simulate free-free boundary condition, test object was hung by 4 bungee cords and excited by using impact hammer. From this test, dynamic properties of the 2nd stage structure of KSLV-I can be obtained. Modal test data are analyzed by using TDAS(Test Data Analysis Software). As the result, modal parameters and mode shapes below 100Hz of the 2nd stage of KSLV-I were identified.

  • PDF