• Title/Summary/Keyword: 대비감도

Search Result 282, Processing Time 0.018 seconds

Use of Piggyback Contact Lens System to GP Lens Wearers (GP렌즈 착용자에게 피기백 콘택트렌즈 시스템의 적용)

  • Kim, Yong Gil;Kim, Soo Hyun;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study was performed to achieve an acceptable piggyback fit utilizing each subject's own GP lenses, in subjects with regular low myopic astigmatism. Methods: A randomized, prospective study of 15 subjects with the diagnosis of low myopic astigmatism was conducted. Nine subjects were female and 6 were male, and mean age was: 23.73${\pm}$1.68 years. Subjects were evaluated before participate on this study and then also evaluated with period of at two hours and two weeks after obtaining their lenses. All subjects were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, best corrected visual acuity and over-refraction at distance. contrast sensitivity and stereo acuity. After evaluating the fit of plano soft lens, we applied each subject's own GP lens on top. Results: Vision, visual performance and satisfaction of piggyback contact lens system were stable, if not improved, for the 15 subjects when the data was compared to the patients' wear of rigid gas permeable contact lenses. Fit with a piggyback system had the same or improved comfort, visual acuity and contrast sensitivity compared to previous GP lens wear alone. The visual acuity, contrast sensitivity and stereo acuity did not show differences in relation to the studied lens type. Conclusions: These results suggest that it is possible to achieve a successful piggyback lens fitting utilizing a patient's own GP lens. The piggyback lens system satisfied the visual performance and visual requirements of this subject with GP lens alone for the correction of low myopic astigmatism.

A Relationship between Kinetic Visual Acuity and Contrast Sensitivity (동적시력과 대비감도의 상관관계)

  • Shim, Moon-Sik;Kang, Hye-Sook;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.225-229
    • /
    • 2014
  • Purpose: The study was to analyze the correlation between kinetic visual acuity (KVA), visual acuity(static visual angle, SVA) and contrast sensitivity. Methods: Ninety-nine undergraduate students studying Ophthalmic Optics were fully corrected by the Topcon CV-3000 Phoropter. The contrast sensitivity was measured for the participants under the photopic condition ($100cd/m^2$) with Vector Vision CSV-1000E at 2.5 meter, while KVA was measured with KOWA AS-4A. The participants were classified into three groups L, M and H depending on the KVA (0.1~0.3, 0.31~0.6 and greater than 0.61, respectively) and were analyzed whether there was the correlation between the contrast sensitivity, visual acuity and refractive error. Results: The KVA was correlated with the contrast sensitivity for 3 cpd (r=0.26), for 6 cpd (r=0.48), for 12 cpd (r=0.38) and 18 cpd (r=0.47). Except for the low frequency of 3 cpd, they all were higher than the one of the SVA and the KVA (r = -0.37). The contrast sensitivity for 3, 6, 12 and 18 cpd was 59.41, 92.22, 38.41 and 14.39 in the group L, respectively. The contrast sensitivity in the group M was 66.03, 108.78, 53.51 and 19.20 and the one in the group H was 70.90, 146.10, 62.90 and 25.33 for 3, 6, 12 and 18 cpd, respectively. Conclusions: The correlation of the contrast sensitivity and the KVA was higher than the one of the contrast sensitivity and the SVA. It can be assumed that the contrast sensitivity will be high if the KVA is high, except for the case for low spatial frequency.

A Subjective Study on the Reverberation Characteristics of Coupled Spaces (음향적으로 결합된 공간의 주관적 잔향감에 관한 연구)

  • Jeong, Dae-Up;Choi, Young-Ji
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.3
    • /
    • pp.65-73
    • /
    • 2008
  • The present work deals with subjective assessments to propose the objective parameter related to the subjective attribute of reverberation in the coupled room varied the aperture opening size. A 1/10 scale model was built and used for the measurements and subjective assessments. For the subjective tests, binaural impulse responses(BIRs) were measured using a dummy head and the measured BIRs were convolved with anechoic recorded music for the presentation over the headphones. The results showed that the perceived reverberation was the largest in the aperture opening size 12.5%(1.97% of mail) room surface area)and decreased with increasing the aperture opening size over 25% (3.94% of main room surface area) in the main room coupled with the secondary reverberant room. In the main room coupled with the secondary absorptive room, there was no changes in the perceived reverberation up to the aperture opening size 6.25%(0.99% of main room surface area) and it gradually decreased with increasing the aperture opening site over 12.5%. The objective parameter, T30/T15, showed a very low correlation with the perceived reverberation in the coupled room varied the aperture opening size but showed a high correlation with a new objective parameter, T30/Tbp, proposed by the authors. Because the late part decay energy more rapidly increases with increasing the aperture opening site than the early and middle part decay energy, the LDT/EDT or T3/T1 is a better quantifier to measure double slopes in the coupled room than the T30/T15.

  • PDF

Clinical Evaluation on Variation of Face Form Angle of Eyewear (안경 안면각 변화에 대한 임상적 고찰)

  • Ko, Da-young;Kim, Ki-hong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.477-484
    • /
    • 2015
  • Purpose: This study was investigated to evaluate the effect of the variation of the face form angle(FFA) of spectacle frame on the visual acuity and the visual function. Methods: The visual acuity, the contrast sensitivity, the stereopsis, and the phoria were measured with the spectacle frame whose the FFA is at $5^{\circ}$ and $25^{\circ}$ and the surveys were conducted on subjective symptoms. Here, 30 adults (14 men and 16 women, average age:$25.46{\pm}3.9$), who did not have ocular diseases and were fully corrected in case of having had refractive error, were to act as experimental subjects for this measurement. Results: The visual acuity and the contrast sensitivity was decreased and the phoria was tended to increase to the esophoria direction at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. The stereopsis was significantly reduced at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. Also when the FFA was larger, the higher the degree of refractive error was, the more the increase of the subjective symptoms such as being blurred characters, being disturbed head, and having sore eyes was, which reveals a statistically significant correlation between them. Conclusions: If the FFA increases, the visual acuity, the contrast sensitivity and the stereopsis was found to decrease and the phoria to increase to the esophoria direction. Therefore it shows that the variation of the FFA of spectacle frame can influence the visual acuity and the visual function.

Properties of Sunglass Lenses by Non-Destructive Test for the Sunglass Standards (비파괴식 검사를 통한 선글라스의 품질에 관한 연구)

  • Lim, Yong-Moo;Shim, Moon-Sik;Sim, Hyun-Seog;Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.125-131
    • /
    • 2001
  • In this study, we compared the properties of 23 high and 55 low price sunglass lenses with the standards in the ordinary optical properties, materials, coloration, UV, IR and luminous transmittance, color acceptance for traffic signal, chromaticity and contrast sensitivity. The ordinary optical properties of the lenses met comparatively the requirements of the KS standard. The HIGH-type and LOW-type lenses were primarily made by glass and acrylate, respectively. In the coloration, HIGH-type was in group around neutral color but LOW-type was distributed widely on the line between 570 nm and 485 nm. There are fails in 7% of HIGH-type and 18% of LOW-type in the stimulus purity of the luminous transmittance. Wavelength of the UV/VIS cut-off was over 350 nm for HIGH-type but 6% of LOW-type was under 350 nm. In the erythemal UV, all HIGH-type met the needs of standards but 5 LOW-type failed with DIN standard In the near UV, KS standard worked in stringency, and HIGH-type showed more failure than LOW-type. The characteristics of the IR transmittance of HIGH-type was better than that of LOW-type. In the color acceptance of traffic signal, all HIGH-type met the needs of ANSI standards but 21.8% of LOW-type failed with the standard. In the contrast sensitivity tested with various coloured sunglasses, the value increased with increasing of Land decreasing of test distance. In view of the results so far, HIGH-type met with excellent properties as compared with LOW-type.

  • PDF

Time-dependent Changes of Visual Acuity After Alcohol Ingestion (음주 후 시간경과에 따른 시력의 변화)

  • Kim, Sang-Yoeb;Lee, Sun Haeng;Moon, Byeong-Yeon;Yu, Dong-Sik;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2008
  • Purpose: This study was designed to investigate the time-dependent changes of visual acuity after alcohol ingestion. Methods: Both the subjective and objective refraction, distant contrast sensitivity, and three needle tests were carried out at 1 and 3 hours after alcohol ingestion. Results: It was found that the degree of myoptization increased as the blood alcohol level increased in the range of average -0.25D ~ -0.35D when tested 1 and 3 hours after alcohol ingestion. Under the same test conditions the increase in blood alcohol resulted in the reduction in the function of dynamic stereopsis. However, the variation in contrast sensitivity was found to be insignificant for all spatial frequencies. Conclusions: The optician has to be well aware of the fact that alcohol could affect the visual acuity and functional tests, therefore inquiring of the alcohol ingestion prior to visual test can be necessary.

  • PDF

The Effects of Sports Vision Training on Baseball Player's Visual Performance and Baseball Records (스포츠비젼 트레이닝이 시기능 및 야구성적에 미치는 영향)

  • Lee, Min-A;Oh, Jae-Man;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.87-97
    • /
    • 2010
  • Purpose: The purpose of this study is to investigate the effects of sports vision training on baseball player's visual performance and baseball records. Methods: All subjects were 21 males of high school baseball players, and they participated on eight weeks of sports vision training program. Pre- and post- test results were obtained for static and dynamic visual acuity, static and dynamic stereo acuity, distance and near phoria, fusional reserves, near point of convergence, contrast sensitivity, visual-reaction time. Results: Statical analysis indicated significant improvement in most of mentioned visual variables and baseball records (p<0.001). Conclusions: It can be concluded that the sports vision training program improves visual skills of baseball players, which could lead to improvement in the baseball records. Vison training will be a promotor for baseball player to enhance their performance if proper test instruments and training course is supplied.

A Study on the Change of Contrast Sensitivity with Breath Alcohol Concentration in Various Luminance (다양한 휘도에서 호흡 알코올 농도에 따른 대비감도 변화 연구)

  • Nam, Soo-Kyung;Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.505-511
    • /
    • 2014
  • Purpose: This study was to investigate the effect of breath alcohol concentration (BrAC) increase with drinking alcohol on contrast sensitivity in the conditions of restricted BrAC. Methods: 23 males in 20s (average age $21.17{\pm}2.19$ years, body mass index (BMI) $22.09{\pm}2.16$) were selected and administered the amount of alcohol to reach 0.05% and 0.08% BrAC calculated by BAC (blood alcohol concentration) Dosing Software program, which was developed as basis of Watson's formula. Then, the contrast sensitivity in various luminance conditions (photopic, mesopic, and mesopic with glare) was measured and compared between these conditions. Results: The contrast sensitivity in all spatial frequency was decreased with BrAC increase. Although BrAC was increased, the peak of contrast sensitivity didn't change as 6 cycle per degree (cpd) in the photopic condition and 3 cpd in the mesopic condition, respectively. But, in the mesopic condition with glare, the peak of contrast sensitivity was shifted from 6 cpd at 0% and 0.05% BrAC to 3 cpd at 0.08% BrAC with increase of alcohol concentration. Conclusions: The increase of BrAC by drinking alcohol induces the decrease of contrast sensitivity in all spatial frequency and the shift of peak of contrast sensitivity, which can cause safety accidents, and may have an effect on various visual tasks.

Study of perception of the visual depth caused by the color correction (입체영상 제작에서 색 보정 결과가 입체감 인지에 미치는 영향 연구)

  • Han, Myung-Hee;Kim, Chee-Yong
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.177-184
    • /
    • 2010
  • These days, as digital producing technique has been developed, 3D imaging technique is used in high-tech computer and T.V. Also study for 3D producing technique is actively in progress. Moreover, as James Cameron's movie, 'Avatar' released in 2009 was a box office hit, the issue about 3D image came to the fore again. At this point, I decided to study the effect of the visual depth caused by the color correction during the post-production stage. The purpose of this study is to offer information about processing effective images through data about the effect of the visual depth that applies the color correction during the post-production stage. Basically, I supposed that color and contract would have effects on depth of 3D image. As a result, I could find out the changes of visual depth, space perception and sense of depth throughout the experiment. Applying this result,, I produced the 15 minutes of 3D advertisement movie and I found out that the color correction during the post-production stage was very effective for 3D depth. The left image and the right image by beam splitter based rig and parallel rig were used for this study. Also I adjusted the strong contrast by the color correction during the post-production stage after correcting convergence and visual depth during editing. As a result, I could produce images which had strong sense of space and sense of depth.

정보사회와 행정정보 공개제도

  • Sin, Gak-Cheol
    • 정보화사회
    • /
    • s.78
    • /
    • pp.36-41
    • /
    • 1994
  • 지난 3월 행정정보공개운영지침이 발표됨에 따라 베일속에 감추어져있던 거대한 정보시장이 그 모습을 드러내고 있다. 오는 7월 시행될 정보공개법에 대비해 공포된 이 운영지침을 통해 정보공개제도의 운영상 효율성을 제고할 수 있는 방안을 모색해 본다.

  • PDF