• Title/Summary/Keyword: 대비감도

Search Result 282, Processing Time 0.033 seconds

Changes of Contrast Sensitivity with Decreasing Luminance in Photopic Conditions (명소시 상태에서 휘도 감소에 따른 대비감도 변화)

  • Lee, Eun Jin;Yoon, Moon Joo;Kim, Soo-Hyun;Yang, Gye Tak;Jeong, Ju-Hyun;Kim, Hyun Jung;Kim, Hyun Il;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.411-417
    • /
    • 2012
  • Purpose: To investigate changes of contrast sensitivity with decreasing luminance in photopic conditions. Methods: Contrast sensitivities for 63 university students were investigated at 5 different luminance levels using FACT chart. Results: All contrast sensitivities measured were in the normal range. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd between 40 and $10cd/m^2$. From an intersection point of two hypothetical lines related with contrast sensitivity for 6 and 3 cpd, we could evaluated that the peak moved from 6 to 3 cpd at about $25cd/m^2$. When luminance decreases from 120 to $10cd/m^2$, contrast sensitivity loss at 6 cpd was most, while contrast sensitivity at 1.5 cpd changed little. We could evaluate that at luminance of more than $25cd/m^2$ evaluated approximately, contrast sensitivity was high in the following order of spatial frequency: 18< 12<1.5<3<6 cpd, while at luminance of less than about $25cd/m^2$ as follows: 18<12<1.5<6<3 cpd. Contrast sensitivity losses with decreasing luminance were also evaluated using the decrements and decrement rates of contrast sensitivity. The decrement of contrast sensitivity was the greatest at 6 cpd, while the decrement rate was the greatest at 8 cpd. Conclusions: We propose that evaluation methods used in this research may be available as another methods to evaluate the changes of contrast sensitivity.

Change of Contrast Sensitivity According to Light Transmittance of Color Lens (색렌즈의 광투과율에 따른 대비감도 변화)

  • Lee, Sun-Haeng;Lee, Yoon-Jeong;Cho, Hyun-Gug
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.925-929
    • /
    • 2009
  • 본 연구는 착색렌즈의 광투과율에 따른 명소시 대비감도의 변화를 분석하여 색렌즈를 착용할 때 색상에 따른 적절한 광투과율 기준을 제시하고자 하였다. 정상 시기능을 가진 남자 24명과 여자 13명을 대상으로, 광투과율 80~90%, 60~80%, 43~60%, 30~43%로 착색된 4개의 색렌즈(회색, 갈색, 적색, 녹색)를 순서대로 착용시키고 F.A.C.T. 시표를 이용하여 대비감도 검사를 실시하였다. 검사 결과, 광투과율이 감소될수록 대비감도는 감소되었고, 시감도는 갈색이 가장 높은 것으로 나타났고, 반대로 적색이 가장 낮은 것으로 나타났다. 대비감도 검사결과를 고려한 색상별 권장 광투과율은 갈색, 회색과 녹색 38% 이상, 적색 52% 이상인 것으로 나타났다. 이러한 결과들로 보아 일상생활에서 눈을 보호할 목적으로 색렌즈를 선택할 때 색상과 그 색상에 적절한 광투과율이 고려되어야 한다.

  • PDF

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF

The Changes in Contrast Sensitivity and Glare Sensitivity when Wearing Circle Contact Lenses after the Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용 시 대비감도 및 눈부심감도 변화)

  • Kwon, Ki Nam;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Purpose: In the present study, the effect of circle contact lenses wear on contrast sensitivity and glare sensitivity in a refractive surgery group was investigated. Methods: The contrast sensitivity and glare sensitivity were evaluated using by CGT-1000 for a non-refractive surgery group as control group(40 eyes) and a refractive surgery group(30 eyes) applied plano circle contact lenses, and pupil size was also measured. The correlation between contrast/glare sensitivity and the pupil size was analyzed. Results: In the refractive surgery group, contrast sensitivity in the range of high spatial frequency decreased with wearing circle contact lenses, and amount of decrease for the refractive surgery group was larger than for the control group. The correlation between pupil size and the change of contrast sensitivity was decreased by wearing circle contact lenses, and the correlation was lower in the refractive surgery group than the control group. Furthermore, the wear of circle contact lenses affected on glare sensitivity. In analyzing the change of glare sensitivity by pupil size, the glare was larger in the refractive surgery group than control group. Circle contact lenses in refractive surgery group were not fitted on the center of cornea. Conclusions: In the present study, it is suggested that the sufficient understanding and consideration about the decrease of contrast sensitivity and the increase of glare by wearing circle contact lenses after the refractive surgery is necessary.

A Comparative Analysis Study on Distance Contrast Sensitivities According to Progressive Lens Design (누진렌즈 디자인에 따른 원거리 대비감도 비교분석 연구)

  • Shin, Dong-Min;Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.241-246
    • /
    • 2013
  • Purpose: The aim of this study was a comparative analysis of the effect of distance contrast sensitivity when wearing free-form progressive lens and conventional progressive lens. Methods: The 20 subjects who do not have any ocular diseases were participated in this study. Contrast sensitivities at 5 different levels of spatial frequency were conducted by using FACT (Stereo Optical, USA). Results: Contrast sensitivity was measured for free-form progressive lens and conventional progressive lens in the order of right eye, left eye and binocular. Right/left/binocular contrast sensitivity values of the free-form progressive lenses compared to the conventional progressive lenses were higher 16%/17%/11% at A(1.5 cpd) of spatial frequency, 11%/5%/5% at B(3 cpd) of spatial frequency, 6%/6%/9% at C(6 cpd) of spatial frequency, 19%/16%/13% at D(12 cpd) of spatial frequency, 4%/3%/18% at E(18 cpd) of spatial frequency. Conclusions: In all the area of spatial frequency, distance contrast sensitivity values were measured highly on free-form progressive lens than on conventional progressive lens.

Comparison of Contrast Sensitivity at Near Between Functional Progressive Addition Lenses and Sigle Vision Lenses (기능성 누진가입도렌즈와 단초점렌즈의 근거리 대비감도 비교)

  • Kim, Chang-Jin;Kim, Hyun Jung;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.381-388
    • /
    • 2010
  • Purpose: This study was to compare the contrast sensitivity evaluated the visual ability at near wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition for 2 months. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses(EYE-T, Chemilens Co., Korea, ADD 0.75D) for 2 months. Corrected visual acuity at distance and near and contrast sensitivity at near were tested right after wearing functional progressive addition lenses to compare wearing single vision lenses. And we had second test after 2 months later. Results: Comparing between test and retest, contrast sensitivity at near wearing functional progressive addition lenses was improved more than wearing single vision lenses at all spatial frequency of right, left and both eyes. Conclusions: There was considered that contrast sensitivity test is useful to evaluate the visual ability as well as quality of near work and can be applied variously.

The contrast sensitivity change of circle contact lens's color by refraction error and illuminance (굴절이상도와 조도에 따른 써클콘택트렌즈의 색상 별 대비감도 변화)

  • Kim, Bo-Yun;Jung, Mi-A;Lee, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.273-279
    • /
    • 2018
  • This study researched how the refraction error and illumination influence to contrast sensitivity when we wear the circle contact lenses. The study population comprised 16 students and adults(5 of Male, 11 of Female). The study population comprised 16 students and adults(5 of Male, 11 of Female), We measured the contrast sensitivity on uncorrected vision, according to color of circle contact and change the illumination of laboratory. The contrast sensitivity by illumination decreased than unaided vision when they wore the color contact lenses and more increased mesopic than photopic. Compared between black and brown lenses, brown was higher the contrast sensitivity than black. Also emmetropia had significantly differences when we compared the contrast sensitivity of subjects who had emmetropia, myopia and myopia astigmatism whether refractive error has or not. Therefore, it is important to provide sufficient understanding and recognition of color contact lenses.

Changes of Contrast Sensitivity According to Light Transmittance of Color Lenses (색렌즈의 광투과율에 따른 대비감도 변화)

  • Lee, Sun-Haeng;Lee, Yoon-Jeong;Cho, Hyun-Gug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3427-3433
    • /
    • 2009
  • This paper attempted to suggest the standards of light transmittance based on the analysis of the changes in contrast sensitivity of photopic condition according to the light transmittance of tinted lenses. The subjects of the experiment were 24 male and 13 female adults with normal ocular functions. They were asked to wear four tinted lenses (gray, brown, red, and green) in turn. The light transmittance of the lenses were 80~90%, 60~80%, 43~60%, and 30~43%, respectively. Contrast sensitivities were measured by using F.A.C.T. chart. The results showed that contrast sensitivities were decreased in proportion to the decrease of the light transmittance, and visual sensitivity of brown lenses were the highest and that of red lenses were the lowest. The results of the experiments suggested that the light transmittance should be over 38% for brown, gray and green lenses, and over 52% for red lenses. Accordingly the appropriate light transmittance should be considered when tinted lenses are selected for the purpose of eye protection in everyday life.

당뇨병환자의 백내장

  • Lee, Tae-Gon
    • The Monthly Diabetes
    • /
    • s.221
    • /
    • pp.17-18
    • /
    • 2008
  • 백내장은 카메라의 렌즈에 해당하는 우리 눈의 수정체에 혼탁이 생겨서 빛이 잘 통과하지 못하는 질환으로 시력저하, 눈부심, 대비감도(다른 세기의 빛을 구별하는 시각능력) 저하, 색각(색채 식별하는 감각)감퇴 등을 유발하는데, 당뇨병환자에서의 백내장에 대해 알아보자.

  • PDF