• 제목/요약/키워드: 대변위

검색결과 122건 처리시간 0.026초

유한 요소법을 이용한 대변위 압전 Bimorph 설계 (Design of Large Displacement Piezoelectric Bimorphs with Finite Element Method)

  • 임종인;노용래;김선욱
    • 한국세라믹학회지
    • /
    • 제34권4호
    • /
    • pp.337-342
    • /
    • 1997
  • This paper describes the design and evaluation of new type piezoelectric bimorph actuator that shows much large mechanical response than those conventional types. The bimorph actuator has modified structure combined with the multilayer actuator(MLA) and the composite multilayer actuator called "Moonie". The design and performancean alysis of bimorph actuator are carried out with Finite Element Method (FEM). Theoretical calculation results show that the generating force and displacement of Moonie-modified bimorph actuator can be improved by about 130% and 150%, respectively. The overshooting and ringing phenomena of the bimorph can be effectively restrained by the pseudo step electric field having a rising time coincied with a period of the fundamental vibration mode of the bimorph.e bimorph.

  • PDF

대변위 측정을 위한 다중화된 광섬유 센서 (A multiplexed fiber-optic sensor for measuring large displacement)

  • 유정애;권일범;조재흥;서대철
    • 센서학회지
    • /
    • 제14권3호
    • /
    • pp.169-179
    • /
    • 2005
  • A multiplexed bend loss type single-mode fiber-optic sensor system was prepared to measure the displacement of several cm of the civil engineering structures such as many bridges, tunnels and various buildings. This bend loss type fiber-optic sensor used the signal difference between two reflection signals due to various bend losses generating at a pair of optical connectors by using OTDR (optical time domain reflectometer) for measuring displacements. And the experiments were conducted for showing the measurement feasibility on the range of 10 cm, and the multiplexing experiments were also performed to measure the displacements of 5 measuring positions of an object by setting these 5 fiber-optic sensors on a single mode fiber simultaneously.

충격하중을 받는 Euler기둥의 동적좌굴 해석 (Dynamic Instability Analysis of Euler Column under Impact Loading)

  • 김형열
    • 전산구조공학
    • /
    • 제9권3호
    • /
    • pp.187-197
    • /
    • 1996
  • Explicit 직접적분법 알고리듬을 사용하여 Euler기둥의 동적 좌굴거동을 해석할 수 있는 수치해석법을 제시하였다. 평면뼈대 유한요소를 기하학적 비선형 거동과 전체좌굴의 영향을 고려할 수 있도록 보의 대변위 이론으로부터 유도하였고, central difference method를 바탕으로 해석 알고리듬을 개발하였다. 다양한 형상, 크기, 재하시간을 갖는 충격하중에 대하여 Euler기둥의 동적좌굴거동과 고유치 문제를 해석하였다. 수치해석 예제를 통하여 본 연구의 결과를 검증하였다.

  • PDF

6절점 2차원 Isoparametric요소의 가우스적분점 수정에 관하여 -선형, 비선형의 정적 및 동적 굽힘해석- (On the Modification of Gauss Integral Point of 6 Node Two Dimensional Isoparametric Element -Linear and Nonlinear Static and Dynamic Bending Analyses-)

  • 김정운;정래훈;권영두
    • 대한기계학회논문집
    • /
    • 제17권12호
    • /
    • pp.3007-3019
    • /
    • 1993
  • For the same configuration, the stiffness of 6-node two dimensional isoparametric is stiffer than that of 8-node two dimensional isoparametric element. This phenomenon may be called 'Relative Stiffness Stiffening Phenomenon.' In this paper, the relative stiffness stiffening phenomenon was studied, and could be corrected by modifying the position of Gauss integral points used in the numerical integration of the stiffness matrix. For the same deformation (bending) energy of 6-node and 8-node two dimensional isoparametric elements, Gauss integral points of 6-node element have to move closer, in comparison with those of 8-node element, in the case of numerical integration along the thickness direction.

마이크로 프레스용 고하중/대변위 액츄에이터 개발 (Development of High Load/Large Displacement Actuator for Micro-press)

  • 김병희;남권선;최종필;김헌영;이낙규
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.458-461
    • /
    • 2005
  • In this paper, a new type of inchworm motion actuator is developed in fabrication of actuators for micro-press machine. This is consisted of three piezoelectric actuators, one is for moving the tool guide and the other are for clamping the guide. The inchworm motor provides both high load and large displacement in small size actuator. PZT has compressive strength and often fails under tensile stress and pulling. Thus, in order to prevent failure, we have designed pre-load housing and accomplished FEM analysis. The pre-load housing was used for determining the optimal design condition by comparing the von-mises stresses with the change of hinge stiffness. Also, in order to predict the performance of the motor under certain conditions, the system model was simulated using MATLAB. This is open loop control actuator and driven by the period of input voltage.

  • PDF

대변위를 고려한 곡선 프리스트레스트 콘크리트 사장교의 비선형 해석 (Nonlinear Analysis of Curved Prestressed Concrete Cable-Stayed Bridge due to Large Deflection)

  • 이재석;최규천
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.341-344
    • /
    • 2006
  • A study for the nonlinear analysis of segmentally erected curved PSC(prestressed concrete) cable-stayed bridge considering the effects due to large deflections is presented. Various case studies regarding the effects of the material nonlinearities and the geometric nonlinearities on the behavior of segmentally erected curved PSC cable-stayed bridge are conducted. The numerical results on the bridge which has relatively low stress profile through the bridge deck section like the example herein show that the geometric nonlinearities has more significant effects on the structural behavior than the material nonlinearities.

  • PDF

오일러 매개변수를 이용한 해양 세장체 대변위 거동 해석 (Euler Parameters Method for Large Deformation Analysis of Marine Slender Structures)

  • 홍섭
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.163-167
    • /
    • 2003
  • A novel method for 3-dimensional dynamic analysis of marine slender structure gas been developed by using Euler parameters. The Euler parameter rotation, which is being widely used in aerospace vehicle dynamics and multi-body dynamics, has been applied to elastic structure analysis. Large deformation of flexible slender structures is described by means of Euler parameters. Euler parameter method is implemented effectively in incremental-iterative algorithm for 3D dynamic analysis. The normalization constraint of Euler parameters is efficiently satisfied by means of a sequential updating method.

  • PDF

대변위-고정밀 위치제어를 위한 자기변형 self-moving cell 선형모터 (Magentostrictive self-moving cell linear motor for displacement control with large force and high resolution)

  • 두재균;김재환;최승복;박홍근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.249-255
    • /
    • 2000
  • The design and test of an magnetostrictive linear motor(MLM) that operates based on self-moving cell concept is presented. The moving cell is composed of Terfenol-D linear actuator and a ring structure, and a cell train is constructed by connecting two cells in series. Since this motor uses the stroke of Terfenol-D actuators and friction force of the cells, it can essentially produce long stroke and large force. The overall performance of the MLM was measured in terms of speed and force. The pushing force is directly related with the friction force. This work is a proof-of-concept stage and investigation is necessary for realistic application.

  • PDF

소아에서 4제요법 후 enzyme immunoassay에 의한 Helicobacter pylori 대변 항원 검출법의 유용성에 대한 연구 (Role of enzyme immunoassay for the Detection of Helicobacter pylori Stool Antigen in Confirming Eradication After Quadruple Therapy in Children)

  • 양혜란;서정기
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제7권2호
    • /
    • pp.153-162
    • /
    • 2004
  • 목적: H. pylori 대변항원(Helicobacter pylori stool antigen; HpSA) 검사는 H. pylori 감염 여부를 진단하는 데 이용되는 비침습적 검사이지만, 소아에서 제균요법 후 H. pylori 대변항원검사의 유용성에 대한 연구가 거의 이루어지지 못한 상태이다. 본 연구에서는 소아에서 H. pylori의 제균 여부를 확인하는 데 있어 enzyme immunoassay에 의한 HpSA 검사의 진단 정확도를 평가하고자 하였다. 연구방법: 2001년 1월부터 2003년 10월까지 서울대학교병원 소아과에서 146명의 소아(평균 연령 $9.3{\pm}4.3$세)를 대상으로 총 164회의 H. pylori 대변항원검사(Primier platinum HpSA)를 시행하였다. H. pylori 감염여부를 확인하기 위해 모든 환아에서 H. pylori 대변항원검사와 상부위장관내시경에 의한 위점막 생검을 병행하였다. H. pylori 감염이 확인되어 사제요법(omeprazole, amoxicillin, metronidazole, bismuth subcitrate)을 1주 동안 시행 받은 환아들에서는 치료 종결 후 최소 4주가 경과하였을 때 위내시경과 H. pylori 대변항원검사를 반복 실시하였다. H. pylori 대변항원검사는 OD값이 0.16 이상일 때 양성, 0.14~0.16 사이는 감염 미확정, 0.14 미만은 음성으로 판정하였다. 결과: 1) 제균 전 시행한 131회의 위내시경 조직검사 결과 28명이 H. pylori 양성이었고 나머지 103명은 H. pylori 음성이었다. 동시에 시행한 H. pylori 대변항원검사 결과에서 30명이 H. pylori 양성이었고, 101명이 음성으로 판정되었다. 따라서 제균요법 시행 전 H. pylori 대변항원검사의 민감도, 특이도, 양성 예측치, 음성 예측치는 각각 96.4%, 97.1%, 90% 그리고 99%이었다. 2) 제균요법 4주 후 33명의 환아에서 시행한 위내시경에 의한 조직검사에서 H. pylori는 24명에서 음성이었으나 9명은 여전히 양성이었다. 동시에 시행한 H. pylori 대변항원검사는 10명에서 양성, 23명에서 음성이었다. 따라서 제균요법 후 H. pylori 대변항원검사의 민감도, 특이도, 양성 예측치, 음성 예측치는 각각 88.9%, 91.7%, 80% 그리고 95.7%이었다. 결론: 소아에서 H. pylori 대변항원검사는 제균 후에도 높은 진단 정확도를 보였다. 따라서 H. pylori 대변항원검사는 소아에서 제균요법 후 균 박멸여부를 확인하는 데에도 매우 유용한 비침습적인 검사방법이라고 하겠다.

  • PDF

병원 내 화장실의 방사성 표면오염도 측정 (Measurement of Radioactive Surface Contamination of the Restroom in the Hospital)

  • 한상현
    • 한국융합학회논문지
    • /
    • 제11권8호
    • /
    • pp.71-76
    • /
    • 2020
  • 본 연구는 병원 내 일반 공용화장실과 핵의학 전용화장실내의 방사성 표면오염도를 측정하였다. 측정방법은 Berthold(LB 124, Germany)을 이용하여 화장실 입구, 대변기 안, 대변기 주위바닥, 소변기 안, 소변기 주위바닥에서 측정하였다. 화장실 사용실태 결과 3곳의 병원 중 1곳의 병원에서 방사성동위원소를 투여 받은 환자가 대기하는 전용장소가 없었다. 방사성동위원소 전용 화장실을 측정한 결과 방사성옥소 치료병실에서 모든 측정 장소가 가장 높게 측정되었고, 공용화장실을 측정한 결과는 B병원을 제외한 모든 병원의 측정 장소에서 백그라운드 수준의 오염도를 나타냈다. 하지만 B병원의 1층 공용화장실 소변기 안, 소변기 주위바닥에서 8.073 Bq/㎠, 6.426 Bq/㎠으로 측정되었다. 따라서 환자들에게 방사선피폭의 위험성을 설명하고, 환자가 대기할 수 있는 장소를 마련할 것을 권고 한다. 그리고 방사성동위원소를 투여 받은 환자는 불필요한 이동과 일반 공용화장실을 사용하지 못하도록 하는 방안이 모색되어야 할 것이다.