• Title/Summary/Keyword: 단층 영상

Search Result 1,413, Processing Time 0.024 seconds

Resolution Improvement of the Positron Computerized Tomography with a New Positron Camera Tomographic System (분해능 향상을 위한 새로운 양전자 단층 촬영기의 제안)

  • Hong, Ki-Sang;Ra, Jong-Beom
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.6
    • /
    • pp.22-30
    • /
    • 1979
  • A new circular ring position camera tomographic system termed "Oscillatory Dichotomic Ring" system is proposed and its performance is simulated. It is basically a circular ring system, composed of two half rings, which has the capability of scanning so that any sampling intervals can be obtained. Since finer sampling means poorer photon statistcs, simulations with varous signal dependent statistical noise effects, ray sampling and arrangement as well as related artifacts peculiar to the proposed Dichotomic Ring system are made.

  • PDF

Shrink-wrapping based surface reconstruction from cross sectional images (표면 축소포장에 기반한 단층영상으로부터의 표면 재구성)

  • Park Eun-Jin;Choi Young-Kyu
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06a
    • /
    • pp.133-135
    • /
    • 2006
  • 단층촬영영상(Tomographic cross-section images)으로부터 임의의 등밀도 표면(iso-density surface)을 재구성하기 위한 새로운 방법을 제안하였다. 이 방법에서는 마칭큐브 알고리즘에 비해 정밀도는 떨어지지만 안정적인 표면을 생성하는 셀경계 알고리즘(Cell-Boundary Method)을 이용하여 초기메쉬를 구하고 이를 표면축소포장(Shrink-wrapping)처리를 통해 정밀한 등밀도 표면을 생성하게 된다. 이는 마칭큐브와 같이 단층영상에서 등밀도 표면을 직접 추출하는 것이 아니라 등밀도점(iso-density Point)을 먼저 추출하고 표면의 모호성이 없는 안정적인 초기메쉬를 이들 방향으로 축소하여 정확한 표면모델링을 가능하게 한다. 이를 통해 마칭큐브에서 발생하는 표면 결정의 모호성이 없이 보다 안정적인 표면을 정확하게 만들 수 있다.

  • PDF

Three-dimensional Imaging with an Endoscopic Optical Coherence Tomography System for Detection of Airway Stenosis (기도협착 측정을 위한 내시경 광 결맞음 단층촬영법을 이용한 3차원 이미징)

  • Kwon, Daa young;Oak, Chulho;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.243-248
    • /
    • 2019
  • The respiratory tract is an essential part of the respiratory system involved in the process of respiration. However, if stenosis occurs, it interferes with breathing and can even lead to death. Asthma is a typical example of a reversible cause of airway narrowing, and the number of patients suffering from acute exacerbation is steadily increasing. Therefore, it is important to detect airway narrowing early and prevent the patient's condition from worsening. Optical coherence tomography (OCT), which has high resolution, is suitable for observing the microstructure of tissues. In this study we developed an endoscopic OCT system. We combined a 1300-nm OCT system with a servo motor, which can rotate at a high speed. A catheter was pulled back using a linear stage while imaging with 360° rotation by the motor. The motor was selected considering various requirements, such as torque, rotational speed, and gear ratio of pulleys. An ex vivo rabbit tracheal model was used as a sample, and the sample and catheter were immobilized by acrylic structures. The OCT images provided information about the structures of the mucosa and submucosa. The difference between normal and stenosed parts in the trachea was confirmed by OCT. Furthermore, through a three-dimensional (3-D) reconstruction process, it was possible to identify and diagnose the stenosis in the 3-D image of the airway, as well as the cross-sectional image. This study would be useful not only for diagnosing airway stenosis, but also for realizing 3-D imaging.

Performance Evaluation of YOLOv5s for Brain Hemorrhage Detection Using Computed Tomography Images (전산화단층영상 기반 뇌출혈 검출을 위한 YOLOv5s 성능 평가)

  • Kim, Sungmin;Lee, Seungwan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.25-34
    • /
    • 2022
  • Brain computed tomography (CT) is useful for brain lesion diagnosis, such as brain hemorrhage, due to non-invasive methodology, 3-dimensional image provision, low radiation dose. However, there has been numerous misdiagnosis owing to a lack of radiologist and heavy workload. Recently, object detection technologies based on artificial intelligence have been developed in order to overcome the limitations of traditional diagnosis. In this study, the applicability of a deep learning-based YOLOv5s model was evaluated for brain hemorrhage detection using brain CT images. Also, the effect of hyperparameters in the trained YOLOv5s model was analyzed. The YOLOv5s model consisted of backbone, neck and output modules. The trained model was able to detect a region of brain hemorrhage and provide the information of the region. The YOLOv5s model was trained with various activation functions, optimizer functions, loss functions and epochs, and the performance of the trained model was evaluated in terms of brain hemorrhage detection accuracy and training time. The results showed that the trained YOLOv5s model is able to provide a bounding box for a region of brain hemorrhage and the accuracy of the corresponding box. The performance of the YOLOv5s model was improved by using the mish activation function, the stochastic gradient descent (SGD) optimizer function and the completed intersection over union (CIoU) loss function. Also, the accuracy and training time of the YOLOv5s model increased with the number of epochs. Therefore, the YOLOv5s model is suitable for brain hemorrhage detection using brain CT images, and the performance of the model can be maximized by using appropriate hyperparameters.

Iterative Data Completion for Limited Angle Tomography using Filtered Backprojection (각도 제한 단층영상재구성을 위한 여현 역투사 기반 반복적 데이터 완결 기법)

  • Lee, Nam-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.3
    • /
    • pp.372-382
    • /
    • 2009
  • When the range of projection angles is limited, tomographic reconstruction suffers from artifacts caused by incomplete data. One can consider a data completion technique, which estimates projection data at unobserved angles using a prior knowledge or mathematical exploration, but the result is often not improved; the improvement by the data completion often undermined by the artifacts by inaccurate estimation, In this paper, we propose an iterative method, which computes projection data at unobserved angles by using the current estimate on the image, links the computed projection data to the observed ones by using the consistence condition of Radon transform, and reconstruct the next estimate on the image by filtered backprojection. The proposed method does not require a prior knowledge on the image, and has much faster approximation rate than the expectation maximization method. The performance of the proposed method was tested through several simulation studies.

  • PDF

Optimization of Exposure Parameters in Brain Computed Tomography (두부 전산화단층촬영에서 노출 파라미터의 최적화)

  • Ko, Seong-Jin;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.355-362
    • /
    • 2010
  • This study determines a range of CT parameter values in Brain CT which are minimizing patient absorption dose without compromising the image quality and optimal exposure condition. We measured dose and image noise using conventional CT parameters in Brain CT. In additon, we evaluated dose, SNR and PSNR of head phantom images while changing kVp and rotation time. In this study, effectiveness of dose that was achieved from dose reproducible experiments in conventional head CT condition is determined by changing kVp and rotation time. Dose and PSNR is related to low dose-high resolution condition. In conclusion, we suggest that using proposed conditions is effective for imaging to compare with conditions proposed by the manufacturer.

Retroperitoneal Ectopic Pregnancy Detected by CT: A Case Report (CT에서 발견된 후복막 자궁외 임신: 증례 보고)

  • Sunjin Ryu;Chul-min Lee;Bo-Kyeong Kang;Mimi Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.217-221
    • /
    • 2024
  • Retroperitoneal ectopic pregnancy is a rare form of ectopic pregnancy. Owing to its rarity and nonspecific symptoms, diagnosing retroperitoneal ectopic pregnancy at the initial presentation poses a significant challenge. Typically, the diagnosis relies on non-radiation imaging modalities, such as ultrasonography and MRI, whereas CT is infrequently used. Herein, we report a rare case of a retroperitoneal ectopic pregnancy, which was diagnosed using CT.

SPSA Approach to Image Reconstruction in Electrical Impedance Tomograhpy (전기 임피던스 단층촬영법에서 SPSA를 이용한 영상복원)

  • 김호찬;부창진;이윤준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.23-28
    • /
    • 2004
  • In EIT, various image reconstruction algorithms have been used in order to compute the internal resistivity distribution of the unknown object with its electric potential data at the boundary. Mathematically the EIT image reconstruction algorithm is a nonlinear ill-posed inverse problem. In this paper, a SPSA approach is proposed for the solution of the EIT image reconstruction. Results of numerical experiments of EIT solved by the SPSA approach are presented and compared to that obtained by the modified Newton-Raphson(mNR) method.

Incidental Extramammary Findings on Preoperative Breast MRI in Breast Cancer Patients: A Pictorial Essay (유방암 환자의 수술 전 유방 MRI에서 우연히 발견된 유방 외 소견: 임상화보)

  • Jin-A Ryoo;Shin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.372-385
    • /
    • 2023
  • Breast cancer is one of the most common cancers and causes several complications in females. Currently, MRI is a necessary method for preoperative studies in patients with breast cancer. A high frequency of breast MRI can lead to an increase in the number of incidental extramammary findings. Moreover, it can provide accurate preoperative workup; therefore, the prognosis of patients can be improved. Herein, we provide several extramammary findings, including the mediastinum, lung, upper abdomen, bone, and soft tissue, correlating with US, chest CT, liver MRI, PET-CT, and bone scan.

Evaluation of Usefulness in New Immobilization Device with 3D CT Angiography for Lower Extremity (전산화단층촬영검사에서 하지의 3D 혈관조영검사를 위한 새로운 고정기구의 유용성 평가)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.184-191
    • /
    • 2007
  • Our objective was to develop and evaluate a non-invasive device for rigid immobilization and surface disease non-contact of the table in the lower extremity during CT angiography. The immobilization device consists of two components. The patient's lower limb device stabilizing elements made of polyethylene resin soft materials, and pelvis parts foam pad is used for non-contact surface. In a Prospective study the lower extremity device was used in patients who underwent a CT angiography of the lower limb. Immobilization with our device was well tolerated by all patients. The quality of the resulting images in the popliteal and infrapopliteal region was rated by five-point scale. The rigid immobilization resulted in a complete absence of motion artifacts. The new device is an effective, well tolerated and easily used immobilization that is suitable of use in 3D lower extremity CT angiography.