Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Stress analysis of Multiloop Edgewise Arch Wire with various degree of tip back bend : a study using the finite element method (Multiloop Edgewise Arch Wire의 tip back 정도에 따른 응력 분포에 관한 유한요소법적 연구)

  • Lee, Young-Il;Cha, Kyung-Suk;Ju, Jin-Won;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.127-142
    • /
    • 2000
  • This study have been carried out to find out the mechnical effect of Multiloop Edgewise Arch Wire(MEAW) making use of the finite element method. The tip back bend of MEAW taken in this analysis is $5^{\circ},\;10{\circ}\;and\;15{\circ}$. In addition, Class II or up & down elastic is applied to find out stress distribution and their values in PDL. A adult male of normal occlusion was selected to create the models of teeth and PDL. And the model of MEAW was also created using commercial finite element code (ANSYS version 5.2). The MEAW is forcibly engaged with a class II or up & down elastic, to determine the initial stress generated in PDL. Comparing the compressive and tensile stress at each reference-planes, following results are obtained. 1. When a MEAW of $5^{\circ},\;10{\circ}\;15{\circ}$ tip back bend was engaged with Class II or up & down elastic, the distribution of compressive, tensile stress in entire PDL is similar in each case. 2. The values of compressive and tensile stress in PDL is higher in $15{\circ}$ tip back bend case than in $10{\circ}\;or\;15{\circ}$ tip back bend case. 3. In the distal PDL of 1st and 2nd molar, compressive stress appears. The compressive area is more wide and its values is higher in PDL of 2nd molar than those in 1st molar. The compressive area and its values become more wide and higher according to the increase of the tip back bend. 4. The values of compressive stress are comparatively smaIIer in PDL of molars than those in premolars. 5. Comparing class II and up & down elastic case, tensile stress values in anterior teeth PDL are smaller md their distribution is more wide in up & down elastic case than class If elastic case. On another hand, there is no difference in distribution and stress values in PDL of posterior teeth between two cases. 6. Comparing the tensile area in PDL of anterior teeth, tensile stress values are maximum in PDL of canine.

  • PDF

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

The Investigation Regarding the Dose Change due to the Heterogeneity of Prostate Cancer Treatment with IMRT (전립선암의 세기조절 방사선치료 시 불균질부에 의한 선량변화에 관한 고찰)

  • Yoon, Il-Kyu;Park, Jang-Pil;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Purpose: The pelvic phantom was fabricated in the following purposes: (1) Dose verification of IMRT plan using Eclipse planning computer, (2) to study the interface effect at the interface between rectal wall and air. The TLD can be inserted in the pelvic phantom to confirm the dose distribution as well as uncertainty at the interface. Materials and Methods: A pelvic phantom with the dimension of 30 cm diameter, 20 cm height and 20 cm thickness was fabricated to investigate the dose at the rectal wall. The phantom was filled with water and has many features like bladder, rectum, and prostate and seminal vesicle (SV). The rectum is made of 3 cm-dimater plastic pipe, and it cab be blocked by using a plug, and film can be inserted around the rectal wall. The phantom was scanned with Philips Brillance scanner and various organs such as prostate, SV, and rectal wall, and bladder wall were delineated. The treatment parameters used in this study are the same as those used in the protocols in the SNUH. TLD chips are inserted to the phantom to evaluate the dose distribution to the rectal wall (to simulate high dose gradient region), bladder wall and SV (to simulate the high dose region) and 2 spots in anterior surface (to simulate the low dose region). The TLD readings are compared with those of the planning computer (ECLIPSE, Varian, USA). Results: The target TLD doses represented as the prostate and SV show excellent agreements with the doses from the RTP within +/-3%. The rectal wall doses measured at the rectal wall are different from the those of the RTP by -11%. This is in literatures called as an interface effect. The underdosages at the rectal wall is independent of 3 heterogeneity correction algorithm in the Eclipse RTP. Also the low dose regions s represented as surface in this study were within +/-1%. Conclusion: The RTP estimate the dosage very accurately withihn +/-3% in the high dose (SV, or prostate) and low dose region (surface). However, the dosage at the rectal wall differed by as much as 11% (In literatures, the underdosage of 9$\sim$15% were reported). This range of errors occurs at the interface, for example, at the interface between lung and chest wall, or vocal cord. This interface effect is very important in clinical situations, for example, to estimate the NTCP (normal tissue complication probability) and to estimate the limitations of the current RTP system. Monte-carlo-based RTP will handle this issue correctly.

  • PDF

A Study on the Necessary Number of Bolus Treatments in Radiotherapy after Modified Radical Mastectomy (변형 근치적 유방절제술 후 방사선치료에서 볼루스 적용횟수에 대한 고찰)

  • Hong, Chae-Seon;Kim, Jong-Sik;Kim, Young-Kon;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.113-117
    • /
    • 2006
  • Purpose: Post-mastectomy radiotherapy (PMR) is known to decrease loco-regional recurrence. Adequate skin and dermal dose are achieved by adding bolus. The more difficult clinical issue is determining the necessary number of bolus treatment, given the limits of normal skin tolerance. The aim of this study is to evaluate the necessary number of bolus treatment after PMR in patients with breast cancer. Materials and Methods: Four female breast cancer patients were included in the study. The median age was 53 years(range, $38{\sim}74$), tumor were left sided in 2 patients and right sided in 2patients. All patients were treated with postoperative radiotherapy after MRM. Radiotherapy was delivered to the chest wall (C.W) and supraclavicular lymph nodes (SCL) using 4 MV X-ray. The total dose was 50 Gy, in 2 Gy fractions (with 5 times a week). CT was peformed for treatment planning, treatment planning was peformed using $ADAC-Pinnacles^3$ (Phillips, USA) for all patients without and with bolus. Bolus treatment plans were generated using image tool (0.5 cm of thickness and 6 cm of width). Dose distribution was analyzed and the increased skin dose rate in the build-up region was computed and the skin dose using TLD-100 chips (Harshaw, USA) was measured. Results: No significant difference was found in dose distribution without and with bolus; C.W coverage was $95{\sim}100%$ of the prescribed dose in both. But, there was remarkable difference in the skin dose to the scar. The skin dose to the scar without and with bolus were $100{\sim}105%\;and\;50{\sim}75%$. The increased skin dose rates in the build-up region for Pt. 1, Pt. 2. Pt. 3 and Pt. 4 were 23.3%, 35.6%, 34.9%, and 41.7%. The results of measured skin dose using TLD-100 chips in the cases without and with bolus were 209.3 cGy and 161.1 cGy, 200 cGy and 150.2 cGy, 211.4 cGy and 160.5 cGy, 198.6 cGy and 155.5 cGy for Pt. 1, Pt. 2, Pt. 3, and Pt. 4. Conclusion: It was concludes through this analysis that the adequate number of bolus treatments is 50-60% of the treatment program. Further, clinical trial is needed to evaluate the benefit and toxicity associated with the use of bolus in PMR.

  • PDF

Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories (동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석)

  • Kang, Min-Young;Lee, Bo-Ram;Kim, You-Hyun;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The aim of the study is to analyze the dose delivery error depending on the depth variation according to target positions and arc trajectories by comparing the simulated treatment planning with the actual dose delivery in conformal arc therapy. We simulated the conformal arc treatment planning with the three target positions (center, 2.5 cm, and 5 cm in the phantom). For the experiments, IMRT body phantom (I’mRT Phantom, Wellhofer Dosimetry, Germany) was used for treatment planning with CT (Computed Tomography, Light speed 16, GE, USA). The simulated treatment plans were established by three different target positions using treatment planning system (Eclipse, ver. 6.5, VMS, Palo Alto, USA). The radiochromic film (Gafchromic EBT2, ISP, Wayne, USA) and dose analysis software (OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany) were used for the measurement of the planned arc delivery using 6 MV photon beam from linear accelerator (CL21EX, VMS, Palo Alto, USA). Gamma index (DD: 3%, DTA: 2 mm) histogram and dose profile were evaluated for a quantitative analysis. The dose distributions surrounded by targets were also compared with each plans and measurements by conformity index (CI), and homogeneity index (HI). The area covered by 100% isodose line was compared to the whole target area. The results for the 5 cm-shifted target plan show that 23.8%, 35.6%, and 37% for multiple conformal arc therapy (MCAT), single conformal arc therapy (SCAT), and multiple static beam therapy, respectively. In the 2.5 cm-shifted target plan, it was shown that 61%, 21.5%, and 14.2%, while in case of center-located target, 70.5%, 14.1%, and 36.3% for MCAT, SCAT, and multiple static beam therapy, respectively. The values were resulted by most superior in the MCAT, except the case of the 5 cm-shifted target. In the analysis of gamma index histogram, it was resulted of 37.1, 27.3, 29.2 in the SCAT, while 9.2, 8.4, 10.3 in the MCAT, for the target positions of center, shifted 2.5 cm and 5 cm, respectively. The fail proportions of the SCAT were 2.8 to 4 times as compared to those of the MCAT. In conclusion, dose delivery error could be occurred depending on the target positions and arc trajectories. Hence, if the target were located in the biased position, the accurate dose delivery could be performed through the optimization of depth according to arc trajectory.

Stress distribution following face mask application using different finite element models according to Hounsfield unit values in CT images (CT상의 HU 수치에 따른 상악골 전방견인 효과의 유한요소 분석)

  • Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.412-421
    • /
    • 2006
  • Objective: The result of finite element analysis depends on material properties, structural expression, density of element, and boundar or loading conditions. To represent proper elastic behavior, a finite element model was made using Hounsfield unit (HU) values in CT images. Methods: A 13 year 6 month old male was used as the subject. A 3 dimensional visualizing program, Mimics, was used to build a 3D object from the DICOM file which was acquired from the CT images. Model 1 was established by giving 24 material properties according to HU. Model 2 was constructed by the conventional method which provides 2 material properties. Protraction force of 500g was applied at a 45 degree downward angle from Frankfort horizontal (FH) plane. Results: Model 1 showed a more flexible response on the first premolar region which had more forward and downward movement of the maxillary anterior segment. Maxilla was bent on the sagittal plane and frontal plane. Model 2 revealed less movement in all directions. It moved downward on the anterior part and upward on the posterior part, which is clockwise rotation of the maxilla. Conclusion: These results signify that different outcomes of finite element analysis can occur according to the given material properties and it is recommended to use HU values for more accurate results.

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.