• Title/Summary/Keyword: 단위 부하량

Search Result 218, Processing Time 0.033 seconds

Filtration characteristic of quantity of coagulant and variable pressure (응집제의 주입량 및 압력변화에 따른 여과특성)

  • Lee, Sung-ho;Lim, Taek-jun;Cho, Jun-hyung
    • Journal of Forest and Environmental Science
    • /
    • v.17 no.1
    • /
    • pp.29-36
    • /
    • 2001
  • Compared to other industries, pulp and paper industry use a lot of water. As a result, a large amount of the waste water is discharged in the pulp and paper industry. This study was investigated to prevent the environmental pollution terribly faced with our society nowadays. In the waste water of pulp and paper, there are so many things in the waste water, like fiber, filler, and other organic solvent etc. so we must remove them from our environment. This study was investigated to experiment on test of impressed filtration with the kind and quantity of coagulant and the variance of pressure. In this study, we used feds, alums. $CaCl_2$, polymer as a coagulant and these pressure was 49, 98, 147, 196kpa. According to this study, we measured the speed of filtration and turbidity, measuring filtrated water. According to the values, we know the fact that as the consistency of coagulant and pressure were high, the filtration was good.

  • PDF

Applicability Analysis of the HSPF Model for the Management of Total Pollution Load Control at Tributaries (지류총량관리를 위한 HSPF 모형의 적용성 분석)

  • Song, Chul Min;Kim, Jung Soo;Lee, Min Sung;Kim, Seo Jun;Shin, Hyung Seob
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.1
    • /
    • pp.1-14
    • /
    • 2022
  • The total maximum daily load (TMDL) implemented in Korea mainly manages the mainstream considering a single common pollutant and river discharge, and the river system is divided into unit watersheds. Changes in the water quality of managed rivers owing to the water quality management in tributaries and unit watersheds are not considered when implementing the TMDL. In addition, it is difficult to consider the difference in the load of pollutants generated in the tributary depending on the conditions of the water quality change in each unit watershed, even if the target water quality was maintained in the managed water system. Therefore, it is necessary to introduce the total maximum load management at tributaries to manage the pollution load of tributaries with a high degree of pollution. In this study, the HSPF model, a watershed runoff model, was applied to the target areas consisting of 53 sub-watersheds to analyze the effect of water quality changes the in tributaries on the mainstream. Sub-watersheds were selected from the three major areas of the Paldang water system, including the drainage basins of the downstream of the South Han-River, Gyeongan stream, and North Han-River. As a result, BOD ranged from 0.17 mg/L to 4.30 mg/L, and was generally high in tributaries and decreased in the downstream watershed. TP ranged from 0.02 mg/L - 0.22 mg/L, and the watersheds that had a large impact on urbanization and livestock industry were high, and the North Han-River basin was generally low. In addition, a pollution source reduction scenario was selected to analyze the change in water quality by the amount of pollution load discharged at each unit watershed. The reduction rate of BOD and TP according to the scenario changes was simulated higher in the watershed of the downstream of the North Han-River and downstream and midstream of the Gyeongan stream. It was found that the benefits of water quality reduction from each sub-watershed efforts to improve water quality are greatest in the middle and downstream of each main stream, and it is judged that it can be served as basic data for the management of total tributaries.

Analysis of Land Use and Pollutant Source Effect on Water Quality Characteristics of the Watershed (유역의 토지이용과 오염원 현황이 수질특성에 미치는 영향 분석)

  • Jung, Kwang-Wook;Jang, Jae-Ho;Kim, Hyung-Chul;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.41-51
    • /
    • 2006
  • The influence of land use and pollutant source on water quality was investigated using 3-yrs monitoring data major influent stream in Hwaong reservoir watershed. The seven water quality station (N1, N2, J1, J3, J4, E2, E3) were used analysis of land use and pollutant effect, and six water quality station (N3, N4, J2, J5, E1, E4) were used analysis of waster quality status. Water quality parameter were positively correlated with residential and forest, negatively with paddy and upland especially during dry period. During wet period, correlation between land use and water quality was less apparent. Population and livestock density was correlated well to water quality parameter than just number of population and livestock. The watersheds studied are mainly non-urban and their land uses are similar to typical watershed of other estuarine reservoirs, therefore, the correlation developed in this study might be helpful to manage other estuarine reservoir watersheds.

Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds (블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구)

  • Joe, Won-Hwa;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.2
    • /
    • pp.97-104
    • /
    • 2010
  • This study evaluated the energy efficiency of a windows system using built-in blinds, with regard to their insulation performance and their blocking of solar radiation. The study took advantage of the "Physibel Voltra" program as a physical simulation of heat transfer. To simulate the "Physibel Voltra" program, I practiced a mock-up test to determine heating quality and translation condition. I analyzed the propensity to annual energy consumption, the annual quantity of heat transfer, and the annual cooling and heating cost through a computer simulation for one general household in an apartment building. In the test, it was found that compared to a general windows system, a windows system with built-in blinds reduced the annual heat transfer by 10% in cooling states and by 11% in heating states when the blind was up. When the blind was down, the windows system with built-in blinds reduced the annual heat transfer by 25% in cooling states and 30% in heating states. When a windows system with built-in blinds is compared with a general windows system, the quantity of cooling and heating loads is reduced by 283.3kw in cooling states and 76.3kw in heating states. This leads to a reduction in the required cooling and heating energy of 359.6kw per house. It is thus judged that the use of a windows system with built-in blinds is advantageous in terms of reducing greenhouse gas emissions, because the annual TOE (tons of oil equivalent) per house is reduced by 0.078TOE, while $tCO_2$ is reduced by $0.16tCO_2$. In addition, compared with a general windows system, the cost of cooling and heating loads in the system reduces the annual cooling cost by 100,000won, and the annual heating cost by 50,000won. Ultimately, this means that cooling and heating loads are cut by 150,000won per year.

Assessment of Pollutant Loads from Alpine Agricultural Practices in Nakdong River Basin (낙동강 수계 고령지 밭의 비점오염 물질 유출 특성 조사 및 단위 유출량 산정)

  • Joo, Jin-Ho;Yang, Jae-E.;Ok, Yong-Sik;Oh, Sang-Eun;Yoo, Kyung-Yeol;Yang, Su-Chan;Jung, Yeong-Sang
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.3
    • /
    • pp.233-238
    • /
    • 2007
  • To assess pollutant loads in Nakdong river from highland agriculture in Kyungbuk province we. analyzed water qualities such as BOD, COD, T-N, T-P and SS in year 2005. BOD values in rainy period (June and July) were relatively higher than those in dry period, and those in 4 sites among 17 sites ranged from 10.71-19.25 mg/L which exceeded water criteria (8 mg/L) for agricultural use. COD values showed similar trends like BOD values. These trends might be caused by outflow of nutrients applied in agricultural lands. T-N content ranged from 0.1 to 14 mg/L. Those in lower reaches of stream were greater in those in upper stream. Compared to T-N contents during non-farming season, T-N content in farming season were higher. These phenomenon could be due to continuous input of nutrients from small watercourses. Averaged T-P content in lower stream during farming season was 0.4 mg/L, which was eight times higher than the limiting level for algae occurrence (0.05 mg/L). BOD, T-P, T-N loads from alpine agricultural practices were 12.25 $kg/km^2{\cdot}day$, 0.55 $kg/km^2{\cdot}day$ and 32.35 $kg/km^2{\cdot}day$, respectively. These values were greater than those from forestry. Therefore, Best management Practices (BMP) for alpine agricultural field are needed to reduce pollutant loads in Nakdong river.

Emission Rate of Greenhouse Gases from Bedding Materials of Cowshed Floor: Lab-scale simulation study (우사깔짚에서 발생되는 온실가스 배출량 산정: 모의 실험결과)

  • Cho, Won Sil;Lee, Jin Eui;Park, Kyu Hyun;Kim, Jeong Dae;Ra, Chang Six
    • Journal of Animal Science and Technology
    • /
    • v.55 no.1
    • /
    • pp.67-74
    • /
    • 2013
  • To know the emission amount of greenhouse gases from bedding materials of cowshed floor, the emission rates of methane ($CH_4$) and nitrous oxide ($N_2O$) gases from a simulated cowshed floor (SCF) with sawdust that manure loading rate into the bedding material could be accurately controlled were assessed in this study. The manure loading rates of Korean beef and Holstein dairy cattle into the SCF of $0.258m^2$ surface area with 10 to 15 cm height sawdust were $1.586kg/m^2/d$ and $3.588kg/m^2/d$, respectively, and those were calculated on the basis of "Standard model for sustainable livestock" and "Data for excretion amount of manure from livestock". All experiments were done in triplicates in three different seasons (May to July, Sep. to Nov., and Feb. to Apr.) using 12 SCFs. The effects of bedding material thickness on $CH_4$ and $N_2O$ emission from SCFs for both Korean beef cattle and Holstein dairy cattle were not statistically significant (p<0.05). Emission amount of $CH_4$ and $N_2O$ per square meter of SCF for Holstein dairy cattle was 7.5 and 1.2 times higher than that of Korean beef cattle, respectively. The yearly $CH_4$ amount per head was 17.7 times higher in Holstein dairy cattle, obtaining 130.4 g/head/year from SCF for Holstein dairy cattle and 7.4 g/head/year from SCF for Korean beef cattle, and $N_2O$ was also 3.8 times higher in Holstein dairy cattle (3,267 g/head/year in Korean beef cattle and 14,719 g/head/year in Holstein dairy cattle). However, the $N_2O$-N per loaded nitrogen into SCF was higher in Korean beef cattle, having 0.2148 and 0.1632 kg $N_2O$-N/kg N in Korean beef cattle and Holstein dairy cattle, respectively, and those values were 3.07 and 2.33 times higher than that of Intergovernmental Panel on Climate Change (IPCC) 2006 guideline (GL) (0.07 kg $N_2O$-N/kg N).

A Study on the Systematic Integration of WASP5 Water Quality Model with a GIS (GIS와 WASP5 수질모델의 유기적 통합에 관한 연구)

  • 최성규;김계현
    • Spatial Information Research
    • /
    • v.9 no.2
    • /
    • pp.291-307
    • /
    • 2001
  • In today's environmental engineering practice, many technologies such as GIS have been adopted to analyze chemical and biological process in water bodies and pollutants movements on the land surface. However, the linkage between spatially represented land surface pollutants and the in-stream processes has been relatively weak. This lack of continuity needs to develop a method in order to link the spatially-based pollutant source characterization with the water quality modeling. The objective of this thesis was to develop a two-way(forward and backward) link between ArcView GIS software and the USEPA water quality model, WASP5. This thesis includes a literature review, the determination of the point source and non-point source loadings from WASP5 modeling, and the linkage of a GIS with WASP5 model. The GIS and model linkage includes pre-processing of the input data within a GIS to provide necessary information for running a model in the forms of external input files. The model results has been post-processed and stored in the GIS database to be reviewed in a user defined form such as a chart, or a table. The interface developed from this study would provide efficient environment to support the easier decision making form water quality management.

  • PDF

Round Robin(RR) ONE-IP: Efficient Connection Scheduling Technique for Hosting Internet Services on a Cluster of Servers (서버 클러스터에서의 인터넷 서비스를 위한 효율적인 연결 스케줄링 기법)

  • 최재웅;김성천
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.04a
    • /
    • pp.736-738
    • /
    • 2001
  • 웹을 사용하는 사용자들의 급속도로 증가하는 서비스 요청을 신속하고 저렴한 비용으로 처리하기 위한 대응책으로, LAN 환경의 웹 서버 클러스터 구조가 각광을 받고 있다. 높은 가용성 및 확장성을 보장하는 웹 서비스를 제공하기 위해 많은 부하의 서비스 요구를 여러 서버에게 효과적으로 나누어 처리할 수 있어야 하며, 따라서 서비스 요청 패킷을 고르게 분배할 수 있는 합리적인 스케줄링 기법을 필요로 한다. ONE-IP 스케줄링 기법은 이더넷의 브로드케스트 메시지에 의해 스케줄링이 분산되도록 하는 전략을 사용함으로써, 클러스터에 유입되는 패킷의 집중화로 인해 발생할 수 있는 병목 현상(bottleneck)과 치명적인 오류(Single-point of Failure) 문제를 효과적으로 해결하였다. 그러나, 서비스를 요청하는 패킷의 발신지 주소만을 이용하는 단순한 패킷 스케줄링을 사용하기 때문에 클러스터를 구성하는 서버들 간의 부하 불균형을 가중시키며, 결과적으로 클러스터의 효율성을 저하시키는 문제점을 가지고 있다. 본 논문에서는 이러한 문제점을 해결하기 위하여 RR ONE-IP 기법을 제안하였다. 제안한 기법은 서버에 할당되는 부하간에 불균형이 발생하는 문제점을 해결하기 위해 TCP 연결 단위의 스케줄링 전략을 사용하였으며, 서버의 부하 정보를 이용하지 않는 RR 스케줄링 기법을 도입함으로써, ONE-IP 기법의 장점을 그대로 유지하면서 보다 나은 부하의 균등한 분배로 시스템의 처리 능력을 향상시키도록 하였다. 또한, 실험을 수행한 결과 제안한 기법이 기존의 기법에 비해 평균 3.84%의 시스템의 성능 향상을 보였으며, 과부하 발생율에서는 평균 23.5%의 감소를 가져왔음을 보였다.우 단어 인식률이 43.21%인 반면 표제어간 음운변화 현상을 반영한 1-Best 사전의 경우 48.99%, Multi 사전의 경우 50.19%로 인식률이 5~6%정도 향상되었음을 볼 수 있었고, 수작업에 의한 표준발음사전의 단어 인식률 45.90% 보다도 약 3~4% 좋은 성능을 보였다.으로서 hemicellulose구조가 polyuronic acid의 형태인 것으로 사료된다. 추출획분의 구성단당은 여러 곡물연구의 보고와 유사하게 glucose, arabinose, xylose 함량이 대체로 높게 나타났다. 점미가 수가용성분에서 goucose대비 용출함량이 고르게 나타나는 경향을 보였고 흑미는 알칼리가용분에서 glucose가 상당량(0.68%) 포함되고 있음을 보여주었고 arabinose(0.68%), xylose(0.05%)도 다른 종류에 비해서 다량 함유한 것으로 나타났다. 흑미는 총식이섬유 함량이 높고 pectic substances, hemicellulose, uronic acid 함량이 높아서 콜레스테롤 저하 등의 효과가 기대되며 고섬유식품으로서 조리 특성 연구가 필요한 것으로 사료된다.리하였다. 얻어진 소견(所見)은 다음과 같았다. 1. 모년령(母年齡), 임신회수(姙娠回數), 임신기간(姙娠其間), 출산시체중등(出産時體重等)의 제요인(諸要因)은 주산기사망(周産基死亡)에 대(對)하여 통계적(統計的)으로 유의(有意)한 영향을 미치고 있어 $25{\sim}29$세(歲)의 연령군에서, 2번째 임신과 2번째의 출산에서 그리고 만삭의 임신 기간에, 출산시체중(出産時體重) $3.50{\sim}3.99kg$사이의 아이에서 그 주산기사망률(周産基死亡率)

  • PDF

Improvement on Management of Non-point Source Pollution for Reasonable Implementation of TMDL - Focusing on Selection of Non-point Source Pollution Management Region and Management of Non-point Source Pollutant - (수질오염총량관리제의 합리적인 시행을 위한 비점오염원관리 개선방안 - 비점오염원 관리지역 선정 및 비점오염물질 관리를 중심으로 -)

  • Yi, Sang-Jin;Kim, Young-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.719-723
    • /
    • 2014
  • For effective implementation of total maximum daily load (TMDL), this study presented the improving plans of non-point source pollution management including the classification of non-point source pollution, calculation of non-point source pollution load (generated, discharged), selection of non-point source pollution management regions and management of non-point source pollutant. First of all, the definition of point source pollution and non-point source pollution based on the legal and scientific viewpoint should be precisely classified and managed. Especially, the forest, grassland and river without occurrence of environmental damage by activity of business and human should be separately classified natural background pollutants. The unit for generated and discharged non-point source pollution should be preferentially changed according to actual condition of watershed. The calculation methods of generated and discharged non-point source pollution should be corrected consideration on the amount and duration of rainfall. While the TMDL is implemented, non-point source pollution management regions should be selected in the watersheds exceed the targeted water quality standards by the rainfall. The non-point source pollution management regions should be selected in the minimal regions where have high values of discharged non-point source pollution density in the urban area, farmland and site area except forest, grassland in the whole watershed. The non-point source pollutant treatment facilities, which take into consideration non-point source pollution load per unit area, duration of the excess concentration, realizable possibility of treatment, effectiveness of treatment cost versus point source pollutant, should be established in the regions with a large generated non-point source pollution load and a high concentration of water quality exceed the targeted water quality standards by the rainfall.

Influence of Filtrate Quality by Variation of Operating Filter Number Based on Inflow (유입유량과 연계한 여과지 가동지수 변동 운영이 여과수 수질에 미치는 영향)

  • Kim, Jin-Keun;Lee, Jung-Tack
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.817-824
    • /
    • 2009
  • To prevent turbidity breakthrough in a depth filter caused by hydraulic shock loads, influence of turbidity and particle number in filtrate by variation of operating filter number depending on inflow change was investigated. Inflow quantity at the S water treatment plant (WTP) was varied and ratio of maximum/minimum inflow quantity was 2.2, therefore filtration velocity was also subsequently changed. The S WTP changed operating filter number depending on inflow variation to minimize change of filtration velocity. Particle breakthrough was not severe when operation system was changed, out-of-operation and re-start of filter was repeated depending on inflow quantity. Slight particle breakthrough was noticed when re-start of filter was implemented at the filter that had a cumulative filtration run time of less than 10 h or more than 50 h. This can be attributed to the inadequate ripening and over accumulation of particles on media. Therefore, it is more efficient to choose a re-starting filter basin which has cumulative filtration run time more than 10 h or less than 50 h to reduce particle breakthrough. Filter number variation depending on inflow change was proven to be a method for improvement of unit filter run volume (UFRV).