• 제목/요약/키워드: 단열 시트

검색결과 43건 처리시간 0.033초

이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용 (Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather)

  • 홍석민;이일선;백대현;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.25-28
    • /
    • 2009
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 5 and $l0^{\circ}C$ even in case outside temperature drops $-11^{\circ}C$ below zero until the 4nd day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

표면개량 버블시트 종류 변화가 서중환경 콘크리트의 온도 및 균열발생에 미치는 영향 (Effect of the Kind of Modified Bubble Sheets on the Temperature Profiles and Crack Reduction of the Concrete under Hot Weather)

  • 이상운;한민철
    • 한국건축시공학회지
    • /
    • 제18권3호
    • /
    • pp.251-257
    • /
    • 2018
  • 여름철 콘크리트는 수분증발에 의한 소성 및 건조수축균열, 슬럼프 저하, 콜드조인트 발생 등 다양한 문제가 발생한다. 이에 국내에서는 수분증발을 방지하고, 단열성능을 확보하기 위해 표면피복 양생을 위한 다양한 형태의 버블시트를 제작하여 사용하고 있으나, 여름철에는 적용사례가 없었다. 따라서 본 연구에서는 여름철 시공중인 아파트 현장에 1중의 투명, 백색 및 알루미늄 증착 버블시트와 PE필름 및 표면노출의 5가지 표면피복 양생재를 적용하여 콘크리트의 온도 및 균열특성 등 품질에 미치는 영향을 분석하였다. 실험결과 알루미늄 증착 버블시트가 온도저감, 균열저감 면에서 가장 뛰어난 것으로 나타났지만, 알루미늄 재질의 특성상 빛이 반사되어 시공자의 눈부심에 따른 시각공해가 발생하기 때문에 백색 버블시트의 사용이 가장 효과적인 것으로 밝혀졌다.

이중버블시트의 포설방법에 따른 콘크리트의 온도이력특성 (Temperature History of Concrete According to the Covering Method of Double Layer Bubble Sheet)

  • 백대현;손호정;홍석민;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.71-72
    • /
    • 2010
  • The study is compared temperature history and strength of concrete followed by covering method of insulation curing of cold weather concrete with double bubble sheet. The results were as follows. First of all, in temperature history of concrete, the internal temperature of concrete fell down to $0^{\circ}C$ before/after 60 hours, having nothing to do with covering method. The study could see that, when sheet was isolated, it fell down to low temperature quickly in early curing. When the study measured compressive strength of core specimen, there were no large differences among placing methods. However, compressive strength fell down in all ages when sheet was isolated.

  • PDF

개량형 2중버블시트 양생막에 의한 온도이력 특성 (Temperature History of the Concrete Cured by the Curing Sheet made with Double Layered Bubble Sheet)

  • 김준호;손호정;손명식;경영혁;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.81-83
    • /
    • 2012
  • This paper is to compare the temperature history of the concrete using existing curing sheet and developed curing sheet made with double layered bubble sheet subjected to clod climate. Field application was conducted. According to results, application of developed curing sheet makes the temperature of curing house and concrete higher than existing curing sheet by about 3℃. This is due to the lower thermal conductivity of developed curing sheet.

  • PDF

2중 버블시트를 이용한 한랭기 콘크리트의 단열양생공법 현장적용 (Field Construction Applying the Insulating Method of Moderate-Cold Weather Concreting Using Double Bubble Sheets)

  • 김종;김종백;전충근;신동안;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.29-32
    • /
    • 2006
  • Experimental test results of field construction, Cheongju University Educational Liberal Art Building, applying the insulating curing method on slab concrete showed that the quality of concrete in fresh and hardened state satisfied all target values. Temperature history of slab concrete in A and B area secured more than $7.8{\sim}9.2^{\circ}C$ higher than outside atmosphere. After completing certain curing period of time on the surface of the structure, crack occurrence was not found. It is concluded that the preventing vaporization of moisture by the insulating curing method reduces plastic and drying shrinkage as welt as improves durability.

  • PDF

이중버블시트를 이용한 단열보온양생공법의 한중매스콘크리트 현장적용 (Field Application of the Mass Concrete Using Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather)

  • 이동규;김종;김기훈;황인성;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.1-4
    • /
    • 2007
  • This study investigated the applicability of insulation curing method with double layer bubble sheets to the man concrete subjected to cold weather. Temperature history of the mass concrete indicated that the highest temperature of center section was exhibited at $34^{\circ}C$ while the that of surface section was $25^{\circ}C$. Difference between center and surface was shown to be less $10^{\circ}C$ when the temperature of center section was peak section, and thereby associated temperature cracking index was calculated 1.5, and occurrence probability of temperature cracking was 5%, so there was no temperature cracking caused by internal restraint. No temperature crack was observed by naked eye. It was clear that early frost demage and temperature cracking could be restrained due to reducing temperature difference between inner part and outside in the case double bubble sheets applied to insulation curing method in cold weather. The maturity of mass concrete is higher than outside about $72\sim89^{\circ}$ DD, so it was demonstrated to prevent early frost demage and ensure strength excellently. Insulation curing method with double bubble sheets was more economic than heating curing method.

  • PDF

엔지니어링 PE방수.방근시트가 결합된 박스 유닛형 옥상 녹화 시스템 적용을 위한 성능평가 (Performance Evaluation for the Application of Roof Green Box Unit System Combined with Engineering P.E.Waterproof and Root Penetration Sheet)

  • 오창원;홍종철;박기봉
    • 한국건축시공학회지
    • /
    • 제16권2호
    • /
    • pp.125-131
    • /
    • 2016
  • 도심지 건물의 증가는 친환경 공간에 대한 요구를 발생시키고, 이에 따라 옥상 및 인공지반 녹화의 보급이 급속히 증가되고 있다. 본 연구는 녹화시스템의 보급 확대를 위해 공법의 단순화, 일체화, 프리훼브화 개념을 적용, 연속 토양층 형성 박스 유닛형 녹화시스템을 개발하고, 이 시스템의 주요 성능으로 부착성, 내풍성, 단열성을 평가하여 적용 가능성을 검토하였다. 부착성 및 내풍성 시험결과, 설계 풍압 및 풍속과 비교하면 100m 높이의 건물에 설치해도 안전한 것을 확인하였고, 단열성 평가를 위해 120일간 측정한 내부 온도의 변화를 분석한 결과, 개발 시스템이 연속된 토양층을 형성하여 기존 유닛박스 시스템보다 주간은 17%, 야간은 45% 우수한 단열성능을 보여 주었다.

양생온도 변화 및 버블시트 두께변화에 따른 콘크리트의 온도이력특성 (Temperature History of Concrete Corresponding to Various Bubble Sheets Layer and Curing Temperature)

  • 홍석민;백대현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.21-25
    • /
    • 2008
  • In this paper, the temperature history and the strength development of concrete corresponded to various bubble sheets layer and curing temperature. Based on the results, In case of the test temperature of -5℃, concrete subject in the exposure condition, result in a frost damage at initial stage by a fall of below zero temperature. In case of the combination of PE film and non woven fabric was after 36 hour, and combination of bubble sheet over double, a tremendous insulating effect of bubble sheet over double is confirmed due to the temperature of concrete fall of below zero temperature after 60 hours. Meanwhile, regarding the -15℃ of temperature, special measure for insulation curing is necessary to secure stability against early frost damage because frost damage was not affected by the lapping thickness of bubble sheet subjected to severe cold weather condition.

  • PDF

이중버블시트를 적용한 매트 기초콘크리트의 부위별 온도이력 특성 (Characteristics of Temperature History at Each Section of Mat Foundation Concrete Applying Double Bubble Sheets)

  • 김태청;김종;전충근;신동안;오선교
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.13-14
    • /
    • 2016
  • This study is aimed to analyze temperature history at each section of mat foundation concrete applying double bubble sheets. The results of the study are as follows. Firstly, the results of measuring the temperature history indicate that the lowest external temperature has been recorded at -5.6℃ for the three-day measurement period. For the central section, the result indicates that the lower, center and upper part have all secured the concrete curing temperature of 18℃ or higher. This results are believed to have resulted from excellent heat insulation performance of double bubble sheets. For the edge section between the edge form and the concrete interface, the temperature has been measured, on average, approximately 12℃ lower than the central section. However, all measured sections have indicated the temperature of 5℃ or higher. Meanwhile, an analysis has been conducted through the estimation equation of compressive strength of maturity during the curing period in order to examine the possibility of early frost damage and the aspect of securing strength. It has been confirmed that the compressive strength is higher than 50°D·D, namely, 5MPa, on the 3rd day of the aging process, which allows early frost damage to be avoided.

  • PDF

동절기 벽식구조 건축물 벽부분의 버블시트 포설방법 변화가 이음부 노출철근의 온도에 미치는 영향 (Influence of Bubble Sheet Applying Methods on Temperature of Exposed Joint Rebar at Wall Surface of Load-Bearing Wall Structure Building During Winter)

  • 한천구;이제현;김민상
    • 한국건축시공학회지
    • /
    • 제17권2호
    • /
    • pp.149-155
    • /
    • 2017
  • 본 연구에서는 겨울철 타설된 콘크리트 표면을 낮은 열전도율 재료로 덮어 주므로서 우수한 단열성을 갖으며, 높은 전용성으로 경제성까지 뛰어난 2중 버블시트에 의한 표면피복 양생공법에 대하여 검토하였다. 하지만, 벽식구조 건축물 시공의 경우 버블시트로 포설되는 슬래브 부분은 초기동해를 방지할 수 있지만, 노출 철근 부분의 경우 버블시트의 포설이 까다롭기 때문에 이 부분에 대한 양생법 변화는 초기동해 피해 여부와 관련하여 의구심이 제기되고 있다. 그러므로, 본 연구에서는 실제 시공중인 벽식구조 Apt 현장의 벽체부분을 동절기 저온 조건하에서 시공하는 것을 모사하여 각종 표면피복 양생방법 변화에 따른 매립 및 노출철근 부분의 위치별 온도 분포 특성을 분석하여 효율적인 양생방법을 제안하고자 하였다. 그 결과, 여러 양생방법 중 D방법의 양생이 가장 우수하게 초기동해를 방지할 수 있는 것으로 판명되었다. 그러나, 시공의 효율성 및 시공의 편리성 까지도 감안하면 철근과 철근의 간격부 만큼에 버블시트를 좁은 폭으로 잘라 덮어주는 B방법도 우수한 방법으로 추천된다.