• Title/Summary/Keyword: 단열 시트

Search Result 43, Processing Time 0.028 seconds

Temperature History of the Concrete for Retaining Wall Insulated with Double Layered Bubble Sheet in Summer (서중기 2중버블시트로 단열처리된 옹벽의 온도이력 특성)

  • Jung, Eun-Bong;Kim, Kyung-Hun;Jang, Deok-Bae;Kyung, Yeong-Hyeok;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.45-46
    • /
    • 2012
  • This study is intended to use the insulation effect of the dual bubble sheet to review the freezing prevention capability of underground walls by pouring the dual bubble sheet on the retaining walls before the concrete pouring to contemplate the temperature profile for each area of installation and the area of non-installation of the dual bubble sheet, and as a result, the temperature of the concrete was heightened than the ground due to the insulation effect in using the bubble sheet.

  • PDF

Temperature History of the Concrete for Retaining Wall Insulated with Double Layered Bubble Sheet in Winter (동절기 2중버블시트로 단열처리된 옹벽의 온도이력 특성)

  • Jung, Eun-Bong;Son, Ho-Jeong;Jang, Deok-Bae;Kyung, Yeong-Hyeok;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.269-270
    • /
    • 2012
  • This study discussed the applicability of double layered bubble sheet(BS) to the concrete for retaining wall to verify the insulation effect as well as prevention of condensation. The BS was applied to the surface of retaining wall, which is contacted with ground. Temperature profile was monitored since placement of concrete. As expected, the application of BS helps the concrete keeping favorable heat insulating, preventing condensation.

  • PDF

Development of Thermal Properties on the Roof Waterproof with Insulation System using the Diffused Reflection Material (확산반사를 이용한 경질시트 옥상 단열방수공법의 열성능 개선에 관한 연구)

  • Koo, Jae-Oh
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.73-80
    • /
    • 2007
  • This paper aims to develop the diffused reflection material in order to reduce the solar absorption coefficient, and to compare the thermal properties with the different roof structure system; one is using the diffused reflection material applied the upper side of the rigid sheet waterproof system and the other is using the conventional up-side down waterproof system on the roof. For this purpose two experimental test boxes were made of same iso-panel wall and floor with different roof system. The experiment was carried out under these process; measure the surface temperature exposed solar radiation of the variation of the reflection materials(cement paste, silica, galvanized steel and titanium dioxide(TiO2)), measure and analyze the variation of the temperature distribution of the each roof system and indoor air in order to evaluate the thermal properties according to the different roof system. The result shows clearly that using the titanium dioxide(TiO2) might be more effective to reduce the solar insolation.

Thermal Performance Evaluation of the Window Systems with Air-bubble Sheets (단열시트(뽁뽁이)의 종류 및 부착위치에 따른 창호의 단열성능 평가)

  • Hwang, Je;Jeong, Ah Hee;Jeon, Byung Heoun;Ahn, Young Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.463-467
    • /
    • 2015
  • The air-bubble sheet has been widely used to wrap fragile products for long-distance transportation. The further usage of the air-bubble sheet as a thermal-insulation material for the reduction of the thermal conductivities of window systems has occurred because of its low price, in addition to its thermal-conductivity properties. In this study, the thermal performances of a variety of commercial air-bubble sheets according to various applications were evaluated. The experiments were performed with single-glazed and double-glazed windows and three types of air-bubble sheets of different air volumes. U-values are used and were calculated for the determination of the thermal performances that are based on the KS F 2278. The maximum decrease of the U-value was measured as 1.092 when a sheet was attached onto the frame of single-glazed window. The square-like air-bubble sheet that contains the largest air volume shows the highest thermal-resistance value. Double layers of the air-bubble sheets show better performances than those of the single layers on both sides of the windows.

A Study on the Heat Performance of Single Layered Bubble Sheet Using Phothothermal Materials (광발열 소재를 활용한 1중 버블시트의 발열성능 검토)

  • Lee, Hyeon-Jik;Hu, Yun-Yao;Lee, Seung-Min;Han, Jun-Hui;Kin, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.223-224
    • /
    • 2023
  • This study compared the curing temperature of the bubble sheet and the photothermal insulation sheet incorporating carbon-based photothermal materials to reduce concrete curing time as a part of shortening construction period. As a result of the experiment, bubble sheet with photothermal material B is judged to be effective in shortening the curing time under hot environment.

  • PDF

Finite element analysis and experiment on the formation of adiabatic shear band in 4340 steel (4340강의 단열 전단밴드생성에 대한 유한요소해석 및 실험적 고찰)

  • 정동택;유요한
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1134-1143
    • /
    • 1994
  • A study of adiabatic shear band formation and propagation of 4340 steel was done using the stepped speciment which was subjected to high velocity impact. The high velocity impact was performed on compression Hopkinson bar impact machine. After the controlled impact, the specimen was prepared for visual inspection. Numerical simulation was also performed with same geometrical dimension using explicit time integration finite element code. Experimental results were then compared with the numerical prediction. It was found that the numerical prediction is quite accurate, average thickness of adiabatic shear band is about $10{\mu}m$, the macro crack around shoulder is due to folding, and the deformation control ring is effective to freeze the propagation of adiabatic shear band.

Insulation Performance Evaluation for Waterproofing Materials that Uses Air Cap Sheet (에어캡시트를 이용한 단열 보완형 방수공법의 단열성 평가)

  • Ma, Seung Jae;Lee, Jong Yong;Choi, Sung Min;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.175-176
    • /
    • 2015
  • Insulation in buildings are one of the crucial factors for energy reduction, and depending on the application areas and properties of the insulation requirements, various different types of insulation materials are being developed, produced, and used. Amongst these is the aircaps often used as packing materials. Because of their porous nature, they are highly efficient in preventing heat and are consequently used overseas often as insulation materials and as part of cold water concrete insulation curing method. This paper studies the recently developed usage of aircaps in waterproofing materials and evaluated their performance as supplementary insulation materials.

  • PDF

Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Baek, Dae-Hyun;Kim, Jong;Jeon, Chung-Kun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete and mass concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 6 and 15℃ even in case outside temperature drops -9℃ below zero until the 2nd day from piling, and in the case of mass concrete, with the maximum temperature difference between the center and surface less than 4℃, crack occurrence index was close to 2 and no hydration heat crack occurred by internal constraint. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

Field Application of Insulation Curing Method for the Concrete applying Double Layer Bubble Sheets Subjected to Cold Weather (이중버블시트를 이용한 단열보온 양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Son, Ho-Jung;Oh, Chi-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.83-85
    • /
    • 2011
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that concrete was protected from early freezing by remaining between 7℃ and 3℃ even in case outside temperature drops -7℃ below zero until the 3d day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF