• Title/Summary/Keyword: 단열 시스템

Search Result 215, Processing Time 0.028 seconds

An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings (공동주택의 단열형태별 선형열관류율 평가)

  • Lee, Jong-Sung;Lee, Do-Heun;Jun, Myoung-Hoon
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • In this study, thermal transmittance which is a parameter to measure the thermal performance was evaluated for an internal insulation versus an external insulation. Then the ISO regulation was applied to evaluate it, and the superiority of an external insulation was verified by the thermal transmittance values. The three zones of apartment housing were selected to evaluate the performance. (1) The junction of an outer wall and a protruded slab : If there is no a thermal bridge protection system, then the values are about same in the two insulation systems, so the protection system should certainly be installed. If it is installed, then the value for the external insulation is 2 times lower than internal system. (2) The junction of a side wall and a flat slab: The value is 0.509W/mK for the internal insulation and about zero for the external insulation. (3) The junction of an outer wall and a division wall: The value is 0.451W/mK for the internal insulation and also about zero for the external insulation. A domestic regulation that could evaluate a thermal transmittance has to be established by applying the ISO regulation for the evaluation of external insulation systems in apartment housing in the future. Additionally, the government must decide which length should be used for the national standard.

Mechanical Properties of External Thermal Insulation Composite System with Quasi-Non-Combustible Performance (준불연 외단열시스템의 역학적 특성에 관한 연구)

  • Choi, Ki-Sun;Ha, Soo-Kyung;Oh, Keun-Yeong;Park, Keum-Sung;Ryu, Hwa-Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.507-518
    • /
    • 2021
  • The application of an adhesive calcium carbonate-based hybrid insulation board with quasi-combustibility in the external thermal insulation composite system(ETICS) ensures effective thermal performance and fire safety. This study aimed to conduct a mechanical test of the quasi-non-combustible hybrid insulation board as well as its constituent materials to obtain the basic data for the structural design of the adhesive ETICS. Test specimens were fabricated based on domestic and foreign test standards to examine and evaluate their tensile, compressive, flexural, and shear strengths. The strength characteristics of the quasi-non-combustible hybrid insulation board were identified from the test results, which verified that the minimum required physical properties suggested by the current KS M ISO 4898 were met. Furthermore, the quasi-non-combustible ETICS used in this study was found to be suitable for use as an external insulation system for walls unless subjected to continuous gravity load, such as a heavy exterior finish.

건축물 에너지절약 설계기준 개정에 따른 온돌시스템 기술개발 방향

  • 강재식;이승언
    • 월간 기계설비
    • /
    • s.143
    • /
    • pp.60-74
    • /
    • 2002
  • 건축물의 에너지 이용을 효율화하기 위하여 단열기준 등을 기존보다 20% 이상 강화하는 것을 골자로 하는 건축물의 에너지절약 설계기준(건설교통부 고시 제2001-118호)이 지난해 6월 1일부터 시행되고 있다. 개정 기준의 가장 큰 특징은 단열기준의 적용 부위를 외기에 직접 면한 부위와 간접 면한 부위로 구분하고, 지역을 중부와 남부, 제주도로 구분$\cdot$설정하여 부하조건과 에너지 소비특성에 따라 건축물의 단열기준을 세분화한 것이다. 특히, 종래에는 최하층 바닥에만 적용하였던 거실 바닥(온돌)의 단열기준을 중간층까지 확대$\cdot$적용하였고, 여기에 온돌시스템의 열적 특성을 고려하여 단열기준의 적용 부위를 보다 구체적으로 설정하고 있다. 따라서 종래의 온돌시스템에서 채움층으로 일반적으로 사용하고 있는 현장 타설식 경량기포콘크리트의 열전도율이 0.13W/mK 내외임을 고려한다면 현행 습식온돌시스템의 열관류율은 $1.0W/m^{2}K$ 이상이 될 것으로 예상됨으로서 앞으로 온돌시스템의 배관층 하부에 $1.0m^{2}K/W$ 이상의 열전도저항을 지닌 단열층이 구성되어야만 개정기준에서 정하는 열관류율 $0.81W/m^{2}K$(기준층 기준)의 성능과 배관하부의 열전도저항값 적용비율을 만족할 수 있을 것으로 판단된다.

  • PDF

Effect of External Thermal Insulation Composite System with a Non-combustible Calcium Silicate Based Mineral on The Mitigation for Reducing Fast Spread of Flame (불연성 무기 단열재를 화재확산 방지구조로 적용한 외단열 마감시스템의 화재성능)

  • Lee, Jong-Chan;Park, Jong-Chul;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.397-403
    • /
    • 2016
  • As a building energy saving standard strengthened, The number of building installed external thermal insulation composite system(ETICS) using EPS insulation increased. But frequent fire accident in the buildings installed EIFS using EPS led to strengthening of building fire safety regulation. This study is for fire property of EPS ETICS reinforced with noncombustible calcium silicate-based mineral insulation as a fire spread prevention structure(FSPS). Fire test for large scale wall by ISO 13785-2 was applied and results showed EPS EIFS with FSPS got 3~8 times superior fire safety than normal EIFS by visual investigation. Temperature and heat flux measurement results, which data of upside of specimen were lower than downside, also supported fire safety of EIFS with FSPS.

The Study of Energy-Efficient Insulation Continuity an Inorganic Insulation (무기 단열재를 이용한 에너지 효율 지속성 단열재 연구)

  • Lee, Jae-Seong;Jeon, Chan-Ki;Kim, Ju-Ho;Park, Jong-Pil
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.166-167
    • /
    • 2015
  • 단열재를 생산하는 회사에서는 대부분 유기단열재를 사용하고 있다. 커튼윌 시스템은 경제적이면서 성능이 우수하지만 불연성이지 않다. 따라서 근래에 안전사고가 많아지고 있어서 타지 않는 무기 단열재가 필요하다. 또한 안전과 단열효과 및 소비자가 요구하는 친환경적인 무기단열재가 필요하므로 불연성 무기단열재의 개발이 시급하다. 본 논문은 무기단열재의 문제인 흡수성을 실험하기 위하여 가습기를 이용하여 흡수성 실험을 하였고 경량골재인 펄라이트와 바인더를 섞고 흡수방지제로 처리한 샘플과 그렇지 않은 샘플의 흡수율을 측정하여 에너지 효율 지속성 단열재의 기술연구를 목표로 한다.

  • PDF

Shear Performance Evaluation of Composite Thermal Insulation with Quasi-Non-Combustible according to Adhesive Type (부착 유형에 따른 준불연 복합단열판 전단성능평가)

  • Choi, Ki-Sun;Oh, Keunyeong;Park, Keum-Sung;Ha, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.5
    • /
    • pp.507-518
    • /
    • 2022
  • The purpose of this research is to obtain experimental data for developing a structural design of an external insulation system by evaluating the shear performance of a composite insulation system according to the adhesive type. The shear performance of the composite insulation system was experimentally evaluated by considering a simultaneous placement method, full and spot/edge coverage using adhesive mortar. As a result of the test, the shear strength of simultaneous placement and full coverage method was almost similar, the spot/edge coverage method was about 80% of them. Also, the simultaneous placement method is considered to be constructively advantageous when applied as an external insulation system to a high-rise building compared to using an adhesive mortar.

Analysis of the statistical properties for the background fractures in the LILW disposal site of Korea (중.저준위 방사성폐기물 처분 부지 내 배경 단열의 통계적 특성 분석)

  • Ji, Sung-Hoon;Park, Kyung-Woo;Kim, Kyoung-Su;Kim, Chun-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.257-263
    • /
    • 2008
  • We analyzed the statistical properties for the conductive background fractures in the Low and Intermediate Level Waste(LILW) disposal site to conceptualize of its groundwater flow system. The background fractures were classified to fracture sets based on their trends and plunges that were obtained from the borehole logging data, and then the fracture transmissivity distribution was inferred from the fixed interval hydraulic test results. The fracture size distribution of each fracture set was estimated using the fracture density and fracture mapping data. To verify the analyzed results, we compared observed field data to simulated one from the DFN model that was constructed with the analyzed statistical properties of the background fractures, and they showed a good agreement.

  • PDF

The Conceptual Framework of Concurrent Construction Method for EIFS in Apartment (공동주택용 외단열 적층시공 공법 개념모델 개발)

  • Lim, Hyunsu;Kim, Taehoon;Cho, Hunhee;Kang, Kyung-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.4
    • /
    • pp.413-423
    • /
    • 2015
  • Exterior Insulation and Finishing System(EIFS) is recognized as a promising alternative for energy reduction as energy reduction ratio of apartment is to be increased from 40% to 60% in 2017. However, EIFS is not actively applied to apartment because additional construction costs and duration are required for the current existing construction method of EIFS. Therefore, this study proposes a conceptual framework for concurrent construction method of EIFS which can reduce construction costs and duration by working sequentially from frame work to exterior insulation finishing work, and then verify the method's feasibility by analyzing a case study. It has been proven from the analysis that concurrent construction method of EIFS reduces 6.7% of construction duration and 13% of construction costs compared with the conventional exiting method. The proposed method is expected to contribute to invigorated application of EIFS to apartment.

Computer Vision-based Automated Adhesive Quality Inspection Model of Exterior Insulation and Finishing System (컴퓨터 비전 기반 외단열 공사의 접착제 도포품질 감리 자동화 모델)

  • Yoon, Sebeen;Kang, Mingyun;Jang, Hyounseung;Kim, Taehoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.165-173
    • /
    • 2023
  • This research proposed a model for automatically monitoring the quality of insulation adhesive application in external insulation construction. Upon case implementation, the area segmentation model demonstrated a 92.3% accuracy, while the area and distance calculation accuracies of the proposed model were 98.8% and 96.7%, respectively. These findings suggest that the model can effectively prevent the most common insulation defect, insulation failure, while simultaneously minimizing the need for on-site supervisory personnel during external insulation construction. This, in turn, contributes to the enhancement of the external insulation system. Moving forward, we plan to gather construction images of various external insulation methods to refine the image segmentation model's performance and develop a model capable of automatically monitoring scenarios with a considerable number of insulation materials in the image.

Performance Evaluation for the Application of Roof Green Box Unit System Combined with Engineering P.E.Waterproof and Root Penetration Sheet (엔지니어링 PE방수.방근시트가 결합된 박스 유닛형 옥상 녹화 시스템 적용을 위한 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.125-131
    • /
    • 2016
  • According to the increment of urban buildings, the demand of eco-environment space will be also increased. Therefore, the artificial ground green system on a roof will be supplied gradually. In this study, the concept of simplification, unification and prefabrication was widely applied to supply green system. Consequently, the box unit system with a continuous soil layer was developed, and adhesive property, wind resistance and insulation property of this system were evaluated for site application. As a results of adhesive property and wind resistance test, comparing with design wind pressure and wind velocity, this system was safe at the height of 100m building located in urban. In addition, results of temperature measurement for 120 days showed 17% higher insulation property at daytime and 45% higher insulation property at night than normal box unit system owing to continuous soil layer.