• 제목/요약/키워드: 단열보온양생

검색결과 17건 처리시간 0.022초

이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용 (Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather)

  • 홍석민;백대현;김종;전충근;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.57-60
    • /
    • 2008
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete and mass concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 6 and 15℃ even in case outside temperature drops -9℃ below zero until the 2nd day from piling, and in the case of mass concrete, with the maximum temperature difference between the center and surface less than 4℃, crack occurrence index was close to 2 and no hydration heat crack occurred by internal constraint. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용 (Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather)

  • 홍석민;이일선;백대현;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.25-28
    • /
    • 2009
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 5 and $l0^{\circ}C$ even in case outside temperature drops $-11^{\circ}C$ below zero until the 4nd day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

양생온도 변화 및 버블시트 두께변화에 따른 콘크리트의 온도이력특성 (Temperature History of Concrete Corresponding to Various Bubble Sheets Layer and Curing Temperature)

  • 홍석민;백대현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.21-25
    • /
    • 2008
  • In this paper, the temperature history and the strength development of concrete corresponded to various bubble sheets layer and curing temperature. Based on the results, In case of the test temperature of -5℃, concrete subject in the exposure condition, result in a frost damage at initial stage by a fall of below zero temperature. In case of the combination of PE film and non woven fabric was after 36 hour, and combination of bubble sheet over double, a tremendous insulating effect of bubble sheet over double is confirmed due to the temperature of concrete fall of below zero temperature after 60 hours. Meanwhile, regarding the -15℃ of temperature, special measure for insulation curing is necessary to secure stability against early frost damage because frost damage was not affected by the lapping thickness of bubble sheet subjected to severe cold weather condition.

  • PDF

이중버블시트의 포설방법에 따른 콘크리트의 온도이력특성 (Temperature History of Concrete According to the Covering Method of Double Layer Bubble Sheet)

  • 백대현;손호정;홍석민;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.71-72
    • /
    • 2010
  • The study is compared temperature history and strength of concrete followed by covering method of insulation curing of cold weather concrete with double bubble sheet. The results were as follows. First of all, in temperature history of concrete, the internal temperature of concrete fell down to $0^{\circ}C$ before/after 60 hours, having nothing to do with covering method. The study could see that, when sheet was isolated, it fell down to low temperature quickly in early curing. When the study measured compressive strength of core specimen, there were no large differences among placing methods. However, compressive strength fell down in all ages when sheet was isolated.

  • PDF

축열형 전기온돌의 난방특성과 진동소음 제거에 관한 실험적 연구 (An experimental research on the heating characteristics and the elimination of noise in electric ondol for off-peak storage use)

  • 현경호;오명환;채성기
    • 전기의세계
    • /
    • 제22권2호
    • /
    • pp.75-86
    • /
    • 1973
  • 본 연구에서는 전기온돌의 안방열손실을 감소시키고 축열효과를 향상시키기 위한 방법을 검토하였으며 전기온돌에서 발생하는 진동소음을 감살시킬 수 있는 대책을 제시하였다. 저육들은 6.6[m$^{2}$] 크기의 전기온돌 model을 이용하여 건물의 구조차이와 하향열단열층의 설치유무에 따른 보온특성의 차이를 기록분석하였으며 그 결과 열전도계수가 0.03[kcal/m.hr.deg. C]정도인 내열성 Styropol과 지석 Mortar로 구성된 하향열단열층을 전기온돌의 마닥에 설치할 경우 난방부하의 감소로 인하여 축열효율이 약 2배나 향상된다는 결론을 얻었다. 또한 전기온돌공사시에 발열선을 지지할 수 있는 대각선형 Spacer를 설치하고 발열선이 매설콘크리트가 완전히 양생된 이후에 전력을 인가하면 흔히 전기온돌에서 발생하는 120-960[Hz]의 가청진동소음을 방지할 수 있다는 사실을 실험적으로 확인하였다.

  • PDF

한중시공에서 2중 버블시트 포설에 따른 단열 효과분석 및 무선센서 네트워크에 의한 초기 품질관리 (Insulation Effect of Double Layered Bubble Sheet Application in Cold Weather Concrete and Initial Quality Control by Wireless Sensor Network)

  • 한민철;서항구
    • 한국건축시공학회지
    • /
    • 제21권1호
    • /
    • pp.21-29
    • /
    • 2021
  • 본 연구는 한중 환경에서 가열 보온양생을 실시한 벽식구조 아파트의 슬래브 상부 및 벽체를 대상으로 2중 버블시트 포설에 따른 온도이력 및 강도발현 특성을 저자 등에 의해 이전 연구에서 개발된 무선센서 네트워크인 Concrete IoT Management System(CIMS)를 이용하여 실시간 모니터링 및 추정하고자 하였다. 분석결과 버블시트의 단열성능에 기인하여 구조체 콘크리트의 온도가 높게 나타났다. 또한, CIMS의 경우는 콘크리트 내부온도를 30 m까지 양호하게 무선센서 네트워크로 스마트폰에 전송되어 적산온도 및 실시간 압축강도 측정으로 효율적인 초기 품질관리가 가능할 수 있음을 알 수 있었다. 초기 품질관리 결과로서 압축강도는 7일 이내에서 약 2 MPa 이내의 오차로 추정될 수 있음에 따라 버블시트의 단열효과까지 포함하여 실무에서는 거푸집 존치기간을 1사이클 당 1일 정도 단축하는 공정관리 측면에서 효과도 얻을 수 있었다.

이중버블시트를 적용한 매트 기초콘크리트의 부위별 온도이력 특성 (Characteristics of Temperature History at Each Section of Mat Foundation Concrete Applying Double Bubble Sheets)

  • 김태청;김종;전충근;신동안;오선교
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.13-14
    • /
    • 2016
  • This study is aimed to analyze temperature history at each section of mat foundation concrete applying double bubble sheets. The results of the study are as follows. Firstly, the results of measuring the temperature history indicate that the lowest external temperature has been recorded at -5.6℃ for the three-day measurement period. For the central section, the result indicates that the lower, center and upper part have all secured the concrete curing temperature of 18℃ or higher. This results are believed to have resulted from excellent heat insulation performance of double bubble sheets. For the edge section between the edge form and the concrete interface, the temperature has been measured, on average, approximately 12℃ lower than the central section. However, all measured sections have indicated the temperature of 5℃ or higher. Meanwhile, an analysis has been conducted through the estimation equation of compressive strength of maturity during the curing period in order to examine the possibility of early frost damage and the aspect of securing strength. It has been confirmed that the compressive strength is higher than 50°D·D, namely, 5MPa, on the 3rd day of the aging process, which allows early frost damage to be avoided.

  • PDF