• Title/Summary/Keyword: 단광

Search Result 17, Processing Time 0.025 seconds

A Study on Usefulness of Planar Bone Scan and Bone SPECT in Diagnosis of Temporomandibular Joint Arthritides (측두하악관절의 관절염 진단에 있어서 골스캔과 단광자방출 전산화 단층촬영의 유용성에 관한 연구)

  • Kim, Chang-Yong;Ahn, Yong-Woo;Park, June-Sang;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.107-119
    • /
    • 2005
  • Temporomandibular joint arthritides is divided into osteoarthritis, osteoarthrosis and polyarthritis. Because the signs, symptoms and radiographical features of osteoarthritis and osteoarthrosis are similar without arthralgia, diffenential diagnosis is difficult. Also non-radiographically change in early Osteoarthritis leads to misdiagnose. Planar bone scan and SPECT are useful to detect bone change early. This study was carried out in order to make diagnostic criteria of planar bone scan and SPECT. Three hundred and four temporomandibular joints were examined with clinical examination, computerized tomograph, planar bone scan, and SPECT. The obtained results were as follows. 1. If temporomandibular joint simple uptake ratio of patient in twenties is over 1.397%, it's condition may be osteoarthritis. And simple uptake ratio over in thirties-fourties may mean osteoarthritis. 2. It may mean osteoarthritis of temporomandibular joint that the number of coronal and transverse SPECT frame with hot spot is over four. 3. Destructive stage may goes on, if simple uptake ratio is over 1.370% in tweenties and over 1.104% in thirties-fourties. 4. If the number of coronal SPECT frame with hot spot is over four, temporomandibular joint may be on destructive stage in tweenties, thirties-fourties. And if the number of transverse SPECT frame with hot spot is over three, it may be on destructive stage in all ages. 5. When patient complains subjective arthralgia and palpation arthralgia, bone change may be more active than each arthralgia. 6. Osteoarthritis may progress gradually worse in 4.5 anamnesis. And then it may be stable gradually and turn to osteoarthrosis.

Construction and Performance Characterization of Time-correlated Single Photon Counting System having Picosecond Resolution (피코초 분해능의 시간 상관 단광자 계수 장치 구성 및 동작 특성)

  • 이민영;김동호
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.90-99
    • /
    • 1994
  • Picosecond time-correlated single photon counting system and time-resolved luminescence spectrometer were constructed, employing a mode-locked picosecond laser, fast electronics, and microchannel plate tube. It has been shown that the instrument response function critically depends on laser pulse shape, timing jitter and walk of the electronics, and characteristics of detector and amplifier. Correcting time dispersion in the optical system, the best instrument response function obtained appears to be 25 ps, which made it possible to measure the luminescence lifetime with less than 10 ps resolution in the picosecond to microsecond range. range.

  • PDF

Prediction of Infarction in Acute Cerebral Ischemic Stroke by Using Perfusion MR Imaging and $^{99m}Tc-HMPAO$ SPECT (급성 허혈성 뇌졸중에서 관류 자기공명영상과 99mTC-HMPAO 단광자방출단층촬영술을 이용한 뇌경색의 예측)

  • Ho Cheol Choe;Sun Joo Lee;Jae Hyoung Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.55-63
    • /
    • 2002
  • Purpose : We investigated the predictive values of relative CBV measured with perfusion MR imaging, and relative CBF measured with SPECT for tissue outcome in acute ischemic stroke. Material and Methods : Thirteen patients, who had acute unilateral middle cerebral artery occlusion, underwent perfusion MR imaging, and $^{99m}Tc-HMPAO$ SPECT within 6 hours after the onset of symptoms. Lesion-to-contralateral ratios of perfusion parameters were measured, and best cut-off values of both parameter ratios with their accuracy to discriminate between regions with and without evolving infarction were calculated. Results : Mean relative CBV ratios in regions with evolving infarction and without evolving infarction were $0.58{\pm}0.27$ and $0.9{\pm}0.17$ (p < 0.001), and mean relative CBF ratios in those regions were $0.41{\pm}0.22$ and $0.71{\pm}0.14$ (p < 0.001). The best cutoff values to discriminate between regions with and without evolving infarction were estimated to be 0.80 for relative CBV ratio and 0.56 for relative CBF ratio. The sensitivity, specificity and efficiency of each cutoff value were 80.6, 87.5, 82.7% for relative CBV ratio, and 72.2, 75.0, 73.0% for relative CBF ratio (p > 0.05 between two parameters). Conclusion Measurement of relative CBV and relative CBE may be useful in predicting tissue outcome in acute ischemic stroke.

  • PDF

A Study on the Resource Recovery of Fe-Clinker generated in the Recycling Process of Electric Arc Furnace Dust (전기로 제강분진의 재활용과정에서 발생되는 Fe-Clinker의 자원화에 관한 연구)

  • Jae-hong Yoon;Chi-hyun Yoon;Hirofumi Sugimoto;Akio Honjo
    • Resources Recycling
    • /
    • v.32 no.1
    • /
    • pp.50-59
    • /
    • 2023
  • The amount of dust generated during the dissolution of scrap in an electric arc furnace is approximately 1.5% of the scrap metal input, and it is primarily collected in a bag filter. Electric arc furnace dust primarily consists of zinc and ion. The processing of zinc starts with its conversion into pellet form by the addition of a carbon-based reducing agent(coke, anthracite) and limestone (C/S control). These pellets then undergo reduction, volatilization, and re-oxidation in rotary kiln or RHF reactor to recover crude zinc oxide (60%w/w). Next, iron is discharged from the electric arc furnace dust as a solid called Fe clinker (secondary by-product of the Fe-base). Several methods are then used to treat the Fe clinker, which vary depending on the country, including landfilling and recycling (e.g., subbase course material, aggregate for concrete, Fe-source for cement manufacturing). However, landfilling has several drawbacks, including environmental pollution due to leaching, high landfill costs, and wastage of iron resources. To improve Fe recovery in the clinker, we pulverized it into optimal -sized particles and employed specific gravity and magnetic force selection methods to isolate this metal. A carbon-based reducing agent and a binding material were added to the separated coarse powder (>10㎛) to prepare briquette clinker. A small amount (1-3%w/w) of the briquette clinker was charged with the scrap in an electric arc furnace to evaluate its feasibility as an additives (carbonaceous material, heat-generating material, and Fe source).

Measurement of fluorecence decay times of single molecules in solution (용액내 단분자의 형광소멸시간 계측)

  • 고동섭
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.1-4
    • /
    • 1999
  • A confocal microscope system was used to study the bursts of fluorescence photons from single dye molecules excited at 638 nm by a short-pulsed diode laser with a repetition rate of 17 MHz. A red dye, JA22, in ethylene glycol solution was used as a sample. The fluorescence decay curves of single molecules were acquired using a time-correlated single photon counting and analyzed by a maximum likelihood estimator. It was possible to measure the fluorescence decay times with an error probability of 21% at photon number of more than 40 per dye molecule.

  • PDF

A Study of Conservative Treatment for Patients with Osteoarthritis of the TMJ (측두하악골관절염 환자의 보존적 치료에 관한 연구)

  • Son, Dae-Eun;Ok, Seung-Joon;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.227-239
    • /
    • 2007
  • To evaluate the treatment outcome after conservative treatment in patients with osteoarthritis of the TMJ(OA), the subjects were chosen among the patients who presented to the Department of Oral Medicine of Pusan National University Hospital, diagnosed as osteoarthritis of the TMJ, and treated with conservative methods from 1994 to 2006. 101 patients with diagnosis of osteoarthritis of the TMJ were selected as the experimental group and 74 patients with diagnosis of masticatory muscle disorders(MMD) were selected as the control group. Subjective symptoms and clinical findings were investigated to evaluate and compare the subject's status at the first and the last visit. The results were as follows : 1. In the OA group, satisfactory treatment outcome was obtained with conservative methods. But, at the last visit, the symptoms of the OA group were not improved enough compared with those of the MMD group. 2. In the OA group, radiographic findings of panorama view and transcranial projection were positive by about 60 percent. But, computed tomography and single photon emission computed tomography were positive by more than 90 percent. 3. At the last visit of the OA group, the joint noise was reduced significantly. 4. In the majority of the OA group, satisfactory treatment outcome was obtained with conservative methods such as medication, physical therapy, and occlusal stabilization appliance. In the majority of the MMD group, satisfactory outcome was obtained with medication and physical therapy. 5. It took the OA group from 6 months to 2 years to be cured well while the MMD group within 6 months.6. The OA group needed more than 10 times' treatment for satisfactory outcome while the MMD group needed less than 10 times' treatment.

Briquetting of Waste Silicon Carbide Obtained from Silicon Wafer Sludges (실리콘 wafer sludge로부터 얻어진 SiC의 단광화 기술)

  • Koo, Seong Mo;Yoon, Su Jong;Kim, Hye Sung
    • Journal of Powder Materials
    • /
    • v.23 no.1
    • /
    • pp.43-48
    • /
    • 2016
  • Waste SiC powders obtained from silicon wafer sludge have very low density and a narrow particle size distribution of $10-20{\mu}m$. A scarce yield of C and Si is expected when SiC powders are incorporated into the Fe melt without briquetting. Here, the briquetting variables of the SiC powders are studied as a function of the sintering temperature, pressure, and type and contents of the binders to improve the yield. It is experimentally confirmed that Si and C from the sintered briquette can be incorporated effectively into the Fe melt when the waste SiC powders milled for 30 min with 20 wt.% Fe binder are sintered at $1100^{\circ}C$ upon compaction using a pressure of 250 MPa. XRF-WDS analysis shows that an yield of about 90% is obtained when the SiC briquette is kept in the Fe melt at $1650^{\circ}C$ for more than 1 h.