• Title/Summary/Keyword: 다이옥신분석

Search Result 53, Processing Time 0.023 seconds

The Study of distribution relationship of dioxin isomers in some environmental matrix (몇 가지 환경 시료 중에 함유된 다이옥신류 이성질체들의 분포에 대한 상관성 연구)

  • Kim, Yunje;Jun, Myung Yoon
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.419-424
    • /
    • 2005
  • In recent years, dioxins which were designated as persistent organic pollutants and endocrine disrupters are treated as substance of environmental pollution and studied about human health risk assessment, emission pollutants estimation, analytical methods and so on. It is easy that dioxins are accumulated to soil because of the atmosphere circulation of burning up the waste. This is the comparative studies on the distribution relationship of dioxin isomers in exhausted gas of industrial waste and urban waste incinerators, ambient air and soil. A basis of PCDDs and PCDFs based on OCDD was drawn up to the curve and they correspond to dioxin isomers in exhausted gas of industrial waste and urban waste incinerators and ambient air. On comparing these results, It was found that the ambient air and exhausted gas of industrial waste incinerators were very similar in curve and ratio. Consequently, environmental by exposed dioxin depends on the exhausted gas of industrial waste incinerators than urban waste incinerators. In case of soil, even though we can not completely rule out the possibility of pollution source bring on pesticide and other factors, and naturally biological dissociations, the curve shape is very similar to exhausted gas of industrial waste incinerators and ambient air. So, we inform here that it was mainly caused by these environmental factors.

Determination of PCDD/Fs in Disposable Diaper for Infant (유아용 일회용 기저귀의 다이옥신 분석)

  • Shin Jeoung Hwa;Ahn Yun Gyong;Seo Jung Ju
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.6
    • /
    • pp.814-824
    • /
    • 2005
  • This study analyzed and standardized the harmful substances of organic compounds(dioxins) in disposable diapers for infant's clothing. Commercial samples obtained from Korea, Japan, America and German were determined by HRGC/HRMS. Experimental Methods were consisted of comparision of extracting solvent, analysis of PCDD/Fs, and analysis of PCDD/Fs of extraction in disposable diaper. The results were as follows. No high TEQ values in TCDD(1), PCDD(0.5) and HxCDD(0.1) were found for commercial disposable diapers from country Korea, Japan, U.S.A and German. In extraction for 6hrs experiments, HpCDD and OCDD were detected in disposable diapers of U1, U2 and G2, respectively. In extraction fur 24hrs experiments, HpCDD, OCDD and OCDF were detected in disposable diapers of J3, U1, U2 and U3. So we need to set standards of measurement for harmful materials contained in textile goods. This will make a safe and comfortable clothing environment for all users, regardless of age.

Determination of PCDD/F in Working Clothes of a Municipal Waste Incineration (생활폐기물 소각장 작업복 샘플의 다이옥신 분석)

  • 박순자;신정화;신정숙;정명희;안윤경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.2
    • /
    • pp.354-363
    • /
    • 2004
  • PCDD/F (Polychlorinated dibenzo-p-dioxins and dibenzofurans) in both of treated fabric and untreated fabric for working clothes of a municipal waste incineration were determinated. The treated fabric for working clothes was developed for less exposure of PCDD/F in municipal waste incinerations. The total concentrations of PCDD/F in some parts such as surface, middle layer, inside for treated and untreated fabric were investigated. The I-TEQ value of surface was 0.23370ng TEQ/g for treated fabric, 0.15355ng $.$ TEQ/g for non-treated fabric. On the other hand, the value of middle layer was 0.00077ng $.$ TEQ/g, 0.00177ng $.$ TEQ/g, respectively. The surface of the treated fabric containing high levels PCDD/F was caused by absorption of them. Therefore, PCDD/F of the treated fabric in middle layer was less I-TEQ value than that of the untreated fabric. The treated fabric makes effect on preventing PCDD/F from permeating into human body.

Characteristics and Sampling of Dioxins/Furans from Emission Gas and Fly Ash Produced in Municipal Waste Incinerator (도시 소각로 쓰레기 소각후 생성된 폐가스 및 비산재중에 포함된 다이옥신류의 측정 및 특성고찰)

  • Lim, Chae-Hyun;Kim, Hee-Taik;Sohn, Jung-Hyun;Chang, Yoon-Seok
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.790-795
    • /
    • 1997
  • Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofuransfurans are the archetype of toxic chemicals. So it has absorbed public attention. The majors primary sources of PCDDS and PCDFs are chemical, thermal and photochemical reactions. Municipal solid waste incinerator facilities has been reported as the major contributors of dioxins to the environment. In this paper, Dioxins and furans were examined emission gas and fly ash produced during combustion in municipal solid waste incinerator. More effective method for sampling, extraction was described. The sample was extracted using a soxhlet method and purified using silicagel, alumina and carbon fibre HPLC to remove interfering compound. The extract was then analyzed by HRGC/HRMS. The result of this study showed recovery standard was good and the data resembled those of thermal processes. Total dioxins and furans were $1076.20pg/Nm^3$ and $1452.34pg/Nm^3$ respectively. The amount of highly chlorinated compound was more than that of lowly chlorinated compound. The 2,3,7,8-substituted TCDD was Just 0.34% of the total dioxins/furans amount.

  • PDF

Exposure assessment of dioxins through foods (식품을 통한 다이옥신류의 노출 평가)

  • Oh, Keum-Soon;Suh, Jung-Hyuck;Paek, Ock-Jin;Kim, Mee-Hye;Lee, Kwang-Ho
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.595-606
    • /
    • 2010
  • A total 221 samples of the retailed foods collected from 2004 to 2007 was examined to estimate the level of dioxins(29 congeners) by the isotopic dilution method, and the exposure of population of Korean to dietary of dioxins was performed. Dioxins levels were calculated using TEF values established in 1998 and 2005, respectively. The average levels (pg TEQ/g) were less than 0.01 for polished rice, 0.04 (poultry)-0.13 (beef) for meats, 0.04 (milk)-0.05(cheese) for milk and dairy products, 0.13 for egg (york, only) and 0.11 (alaska pollack)-1.35 (pacific mackerel) for fishes. The estimated daily intake of Korean through foods was 0.47 pg TEQ/kg bw/day, and it was estimated as about 11% to tolerable daily intake (TDI; 4 pg TEQ/kg bw/day) of Korea and Japan. Consequently, it was concluded that there was no health risk.

Estimation of conbined uncertainty for dioxin reference materials from the fly ash (소각재에 함유된 다이옥신의 확장불확도 평가)

  • Kim, Woo-Il;Shin, Sun-Kyoung;Lee, Su-Young;Kim, Dong-Hoon;Kang, Hak-Gu;Han, Jin-Suk
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.363-370
    • /
    • 2010
  • This study was performed to validate reference materials (RMs) for proficiency testing (PT) in waste inter-laboratories. Dioxin RMs were prepared from fly ash in industrial incinerators. The relative standard deviations (RSDs) of analytical results were 2.6~15.7% for the dioxin RMs in 10 replicates (between and withinbottles). Data were collected and statistical analysis was performed by the One-way ANOVA test. The combined uncertainties of target isomers in dioxin analysis were 0.114~7.091.

Quantification and Resolution of Dioxins on Capillary Columns (캐필러리 컬럼 종류에 따른 다이옥신 이성체 분리능과 정량 특성 변화)

  • Kim, Jong-Guk;Park, Jin-Soo;Kim, Kyoung-Sim;Lee, Geun-Hee;Kim, Shin-Jo
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.43-53
    • /
    • 2002
  • The analysis of polychlorodibenzo-p-dioxins (PCDDs) and polychlorodibenzo furans(PCDFs) was performed by using four different gas chromatographic columns (SP-2331, DB-5, DB-17 and DB-DIOXIN). The data reported is pertaining to flue gas, fly ash, ambient air, soil and fish. The difference in quantification of samples according to four columns was observed, it was noted that major difference was observed in the flue gas when compared with soil, fly ash, ambient air and fish. The quantification of the same samples according to four columns it was also found that DB-5 column have the highest concentration whereas SP-2331 column showed the lowest concentration. The quantification of DB-17 column for 1,2,3,6,7,8-HxCDF was found to be twice and three times higher when compared with other columns, whereas the quantification of DB-DIOXIN column for 1,2,3,7,8-PeCDD was also found to be over estimated twice when compared with other columns.

The Levels of PCDFs and PCDDs in the four kinds of Fish in Korea (우리 나라에서 많이 소비되고 있는 몇가지 생선류 중의 PCDFs와 PCDDs 함유도 조사)

  • Kim, Yunje;Lee, SunYoung;Lee, Hyomin;Yoon, Eunkyung;Yang, KyuHwan;Kim, EunKyung;Kim, Myungsoo
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.142-148
    • /
    • 2002
  • They were analyzed that the levels of PCDDs/PCDFs in mackerel, walleye pollack, croaken and cuttlefish, which were mainly consumed in Korea, by high resolution gas chromatography/high resolution mass spectrometr (HRGC/HRMS). The samples measured in this study had been bought 3 sets of each fish from different 5 cities, Seoul, Chunchon, Daejon, Kwangju and Pusan. The TEQ level of PCDDs in mackerel (0.032 pgTEQ/g) was the highest. The TEQ level of PCDFs in walleye pollack (0.010 pgTEQ/g) was the lowest. The level of PCDDs was higher than PCDFs in fish.