• Title/Summary/Keyword: 다이아그리드

Search Result 21, Processing Time 0.023 seconds

Experimental Evaluation of Seismic Performance Factors for Tall Diagrid Structure (초고층 다이아 그리드 구조의 실험적 내진성능계수 평가)

  • Bae, Jae-Hoon;Ju, Young-Kyu;Kim, Young-Ju;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.75-85
    • /
    • 2010
  • A new freeform structure representing "Diagrid, Cantilevered, Tilted." which has been considered not only its distinctive appearance but also the structural advantages becomes one of the trends in tall building design. Especially in the Diagrid system, loads can be distributed through bracing frame so that it can be save the materials since it has more effective in the structure behavior. But the seismic performance index such as response modification factor is not clearly defined yet. Even though the diagrid is supposed to show higher seismic performance, it is underestimated due to the lack of reliable data. In this paper the response modification factor for the diagrid system is experimentally explored.

Evaluation of Seismic Performance Factors of Diagrid Structural System (다이아그리드 구조 시스템의 내진성능계수 평가)

  • Kim, Kyoung-Hwan;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.229-239
    • /
    • 2010
  • As a new structural system, the diagrid system resists both gravity and lateral loads with diagonal columns. In current seismic design provisions, however, the response modification factor for a new structural system is not provided yet. ATC-63 provides a new methodology for defining various seismic performance factors, including the response modification factor. ATC-63 includes the collapse margin ratio in modifying the response modification factor, which can vary with many structural systems. In this paper, a non-linear static analysis and a dynamic analysis were conducted for four different diagrid models with 4-to 36-story heights. From these analyses, the response modification factor of the diagrid system was evaluated.

Sensitivity Analysis on the Lateral Behavior of Diagrid Structure (다이아그리드 구조 시스템의 횡적 거동에 대한 민감도 해석)

  • Ahn, Keun-Woo;Yang, Jae-Kwang;Park, Sung-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.73-82
    • /
    • 2015
  • In evaluating lateral behavior on the seismic and wind load, the purpose of sensitivity analysis is to find critical variables and to identify characteristic response with variability of variables. The sensitivity analysis is very important in structural diagnosis, repair and reinforcement field. This study investigates the sensitivity by linear static analysis applying the TDA method in changing angles of diagrid braces on the same height structures. In case of mid rise model, under the seismic load, the brace member is determined as a major variable at $58^{\circ}$ but a high rise model, under the wind load, has the brace member as a major variable at $67.4^{\circ}$. In addition, location of critical sensitivity on the mid rise model is distributed over middle section, while it is distributed lower section on the high rise model.

Seismic Performance Evaluation of Complex-Shaped Tall Buildings by Lateral Resisting Systems (횡력저항시스템에 따른 비정형 초고층건물 내진성능평가)

  • Youn, Wu-Seok;Lee, Dong-Hun;Cho, Chang-Hee;Kim, Eun-Seong;Lee, Dong-Chul;Kim, Jong-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.6
    • /
    • pp.513-523
    • /
    • 2012
  • The objective of this research is to examine how the lateral resisting system of selected prototypes are affected by seismic zone effect and shape irregularity on its seismic performance. The lateral resisting systems are divided into the three types, diagrid, braced tube, and outrigger system. The prototype models were assumed to be located in LA, a high-seismicity region, and in Boston, a low-seismicity region. The shape irregularity was classified with rotated angle of plane, $0^{\circ}$, $1^{\circ}$, $2^{\circ}$. This study performed two parts of analyses, Linear Response and Non-Linear Response History(NLRH) analysis. The Linear Response analysis was used to check the displacement at the top and natural period of models. NLRH analysis was conducted to invest base shear and story drift ratio of buildings. As results, the displacement of roof and natural period of three structural systems increase as the building stiffness reduces due to the changes in rotation angle of the plane. Also, the base shear is diminished by the same reason. The result of NLRH, the story drift ratio, that was subject to Maximum Considered Earthquake(MCE) satisfied 0.045, a recommended limit according to Tall Building Initiative(TBI).

An Structural Design for Cyclone Tower's Connections Using Diagrid System (다이아그리드 구조시스템의 접합부개발과 성능평가)

  • Lee, Se-Jung;Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2010
  • Recently, High-rise building are irregular-shaped to be city landmarks and function as vertical cities to enable the efficient use of land. 3T (Twisted, Tilted & Tapered) designs are being suggested for irregular buildings and studies to develop new structural system have been actively made to satisfy slender shape ratio. In diagrid system, not only gravity load but also lateral load is delivered based on the triangular shape of diagrid, so most of columns are eliminated. Because shearing force is delivered by the axial behavior (tensile/compressive) of diagrid to minimize shearing deformation, the system is more applicable to irregular buildings than existing system where shearing force is delivered by the columns. In this study, the process of selecting connection details and the structural safety of the selected details are verified using the finite element analysis with focus given to the construction overview of the Cyclone Tower. However, the relersed methods of stress concentration are suggested and the performance of stress concentration relieves that it's suggested for the appropriate cap plate thickness and extended length.

  • PDF

Simple Model for Preliminary Design of Hexagrid Tall Building Structure (헥사그리드 고층건물구조의 예비설계를 위한 단순모델)

  • Lee, Han-Ul;Kim, Young-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.13-20
    • /
    • 2017
  • High-rise building shapes are changing from orthogonal to irregular form and the current trend is to arrange members in geometric grid-patterns at the perimeter of buildings. This study proposes a simple model for the preliminary design of a hexagrid high-rise building. The size of the cross section is set to be different at each module and hexagrid unit, which is different from the previous studies in which all hexagrid members were the same. To examine the effect of hexagrid size on structural performance, 60-story hexagrid buildings with 1-, 2- and 4-story high modules are designed and analyzed. Maximum lateral displacement, steel tonnage, load carrying percentage of perimeter frame and combined strength ratio are compared for 15 buildings. As the lateral load carrying capacity of hexagrid structure was inferior to a diagrid structural system, proper lateral stiffness should be allocated to the core frame in a hexagrid structure. The best ratio of flexural to shear deformation was 4 and larger unit size was better in considering constructional cost and structural efficiency. As the maximum lateral displacements of the buildings were within 84%~108% of the limit, the proposed method seems to be applicable to preliminary design of hexagrid buildings.

Seismic Performance Evaluation of Freeform Diagrid System (비정형 Diagrid System의 내진성능 평가)

  • Ko, Chang-Kyun;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.189-198
    • /
    • 2011
  • Many new structural systems have been developed to build free-form structures, which is the new architectural trend for aesthetic beauty. The diagrid system resists both gravity and later loads, with its perimeter-diagonal columns. In the current seismic-design provisions, however, a seismic-performance factor for a new structural system has not yet been provided. ATC-63 provides a new methodology for defining various seismic-performance factors, including the response modification factor. In this paper, nonlinear static and dynamic analyses were conducted for the 3D diagrid frame, with each load applied at $0-180^{\circ}$ degrees. Through these analyses, the seismic performance of the diagrid system was evaluated.

A study on Development of Stress Tolerant Structural System in the Frame of Greenhouses (내재해성이 우수한 비닐하우스골조 구조시스템 개발에 관한 연구)

  • Shim, Jong-Seok;Lee, Choon-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.1
    • /
    • pp.5-13
    • /
    • 2012
  • The frame of pipe greenhouses in Korea have been collapsed increasingly due to very weak in structure caused by the heavy snow and strong wind. In order to reduce the collapse of green houses, it is urgent to develop the new structural system in stress tolerant greenhouses. Therefore, this paper performed the structural analysis of greenhouse frame in accordance with snow loads and wind loads. Three type models in structural frame configuration of greenhouses, that is, existing type, diagrid type, and honeycomb type are selected. It was classfied the section shape of structural frames in greenhouses into arch style, standard style, and diagonal standard style. As a result of this paper, it was verified that the structural system of diagrid type is better than that of existing type against snow loads and wind loads in the frame of greenhouses.

Economic Evaluation of High-Strength Steel for Structural Member Types in Building Structures (부재 종류에 따른 고강도 강재의 경제성 평가)

  • Kim, In Ho;Cho, So Hoon;Kim, Jong Ho;Lee, Chul Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.2
    • /
    • pp.113-121
    • /
    • 2013
  • The structural steel produced in domestic is classified into 5 grades. For economic structural design, the structural engineers need to choose optimal steel grades for structural member types, but the related data is not sufficient. Recently, high strength steel with yield strength in 650MPa was developed in domestic. It provides structural engineers with the wider range of structural steel strength, which leads to the larger difference in economic evaluation. In this paper, the economic evaluation of high-strength steel in building structures is investigated, by applying structural steel with 235MPa, 325MPa and 650MPa in yield strength to various types of structural members, and can be used as basic data for economic structural design.

Applications of Construction Sequence Analyses to Prototype Models of Twisted Tall Buildings (비틀림 초고층 프로토타입 모델에 대한 시공단계해석의 적용)

  • Choe, Mi-Mi;Kim, Jae-Yo;Eom, Tae-Sung;Jang, Dong-Woon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.89-97
    • /
    • 2013
  • With regard to complex-shaped tall buildings whose plans and constructions have been gradually on the increase, this study was aimed to analyze their structural behaviors during construction by applications of construction sequences analyses to prototype models. For twisted tall buildings, total 18 models of with three conditions of a lateral load-resisting system, a twisting angle, and a construction method were selected. A diagrid system and a braced tube system were applied as a lateral load-resisting system. For each lateral load-resisting system, three types of plan with $0^{\circ}$, $1^{\circ}$, and $2^{\circ}$ twisting angles and three construction methods with construction sequences of exterior tube and interior frame were assumed. The structural performances of tall buildings under constructions were analyzed with results of lateral displacements from construction sequence analyses. Also, construction performances of the construction period and the maximum lift weight were compared.