• Title/Summary/Keyword: 다양도

Search Result 96,119, Processing Time 0.116 seconds

Weed Occurrence in Upland Crop Fields of Korea (최근(最近) 한국(韓國)의 전작지(田作地) 잡초발생(雜草發生) 분포(分布)에 관(關하)여)

  • Chang, Y.H.;Kim, C.S.;Youn, K.B.
    • Korean Journal of Weed Science
    • /
    • v.10 no.4
    • /
    • pp.294-304
    • /
    • 1990
  • For the survey of weed distribution in the cultivated upland of Korea, weed species were investigated at 2 field by crop of 2 myon per kun in 81 kun selected among the 139 kun of the whole country. 232 species in 46 families were observed, totally. From among the result, 165 species in 39 families the in winter crop field, 189 species in 41 families in the summer crop field were classified. 122 species in 34 families were emerged the from the upland crop field of the whole season. Further more, in the 10 dominant weed species which emerged from upland crop field, Alopecurus aequalis, Chenopodium album, slellaria media, Galium spurieum, Capsella bursa-pastoris and Rorippa islandica were dominated in the winter upland and paddy field, and that Erigeron canadensis, Cyperus amuricus, Equisetum arvense and Arenaria serpyllifolia were dominated in the winter upland field, additionally. Stellaria alsine, Bothriospermum tenellum, Trigonotis peduncularis and Polygonum arviculare were dominated in the winter cropping on drained paddy field, additionally. In the summer crop field, Digitaria sanguinalis, Portulaca oleracea, Acalypha australis, Echinochloa crus-galli, Setaria viridis, Persicaria hydropiper, Amaranthus lividus, commelina communis, Chenopodium album and Cyperecs amuricus were dominated.

  • PDF

The Evaluation of Factors Which Influence Binding Efficiency of Modified in Vivo Erythrocyte Labeling Technique (변형 체내 표지법에 의한 적혈구 표지시 결합효율에 영향을 미치는 인자 평가)

  • Seo, Han-Kyung;Kim, Min-Woo;Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.300-305
    • /
    • 2004
  • Purpose: We underwent this study to evaluate the factors which influence labeling efficiency when modified in vivo erythrocyte labeling technique was used. Materials and methods: Thirty healthy volunteers (M:F=19:11, age:$25{\pm}2$ yrs) were enrolled in this study. Totally, two hundred ten samples were obtained from them. The 1 mg of stannous pyrophosphate was injected intravenously at the beginning of labeling. After suitable tinning time (5 min, 20 min, 35 min) passed by, blood (5 mL, 3 mL or 1 mL) was withdrawn into 10 mL syringe previously containing Tc-99m (740 MBq) and anticoagulant (heparin, ACD or CPDA) through 19-gauged scalp needle. The generator ingrowth time of Tc-99m was within 24 hrs in each case. The blood samples were placed on rotating invertor during incubation (10 min, 25 min, 40 min) but some of them were not. Immediately after the conclusion of incubation, the labeled blood specimens to analyze were centrifuged. and then %Unbound Tc-99m was calculated. Statical analysis was used paired T-test and one way ANOVA with SPSS 10.0. Results: The binding efficiency at 1 mL of blood volume was $73{\pm}32%,\;91{\pm}10%$ at 3 mL and $96{\pm}7%$ at 5 mL (p<0.01). The binding efficiency at 5 min of tinning time was $45{\pm}23%,\;98{\pm}6%$, at 20 min and $97{\pm}8%$ at 35 min (p<0.001). The binding efficiency at 10 min of incubation time was $96{\pm}7%,\;95{\pm}12%$ at 25 min and $98{\pm}3%$ at 40 min (p>0.05). The binding efficiency in case of using rotating invertor was $96{\pm}7%$ and the binding efficiency in case of not using it was $87{\pm}18%$ (p>0.05). There was no significant difference between them. In binding efficiency according to kinds of anticoagulants, ACD was $98{\pm}4%$, CPDA was $97{\pm}6%$ and heparin was $89{\pm}20%$ (p<0.001). Conclusion: When modified in vivo erythrocyte labeling technique is used with Tc-99m, the methods to obtain the highest labeling efficiency are as follow. The withdrawing blood volume should be over 3 mL, tinning time should be kept between 20 min and 35 min, and incubation time should be kept between 10 min and 40 min. ACD or CPDA have to be used as a anticoagulant except heparin and the blood samples should be placed on rotating invertor during incubation.

Angiotensin Converting Enzyme Gene Polymorphism in Alport Syndrome (알포트증후군 환자에서 안지오텐신전환효소 유전자 다형성의 의의)

  • Kim Ji-Hong;Lee Jae-Seung;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.8 no.1
    • /
    • pp.18-25
    • /
    • 2004
  • Purpose : Alport syndrome is clinically characterized by hereditary progressive nephritis causing ESRD with irregular thickening of the GBM and sensory neural hearing loss. The mutations of type IV collagen gene(COL4A5) located on the long arm of X chromosome is considered responsible for most of the structural abnormalities in the GBM of Alport patients. Since no definite clinical prognostic predictor has been reported in the disease yet, we designed this study to evaluate the significance of genetic polymorphism of the angiotensin converting enzyme in children with Alport syndrome as a prognostic factor for disease progression. Methods : ACE I/D genotype were examined by PCR amplification of the genomic DNA in 12 patients with Alport syndrome and 12 of their family members. Alport patients were divided into two groups; the conservative group, those who had preserved renal function for more than 10 years of age, the early CRF group, those who had progressed to CRF within 10 years of age. Results : The mean age of onset was $3.45{\pm}2.4$ years in the conservative group, $4.4{\pm}1.2$ years in the early CRF group. Sex ratios were 5:3 and 2:1 in each group. Among 12 cases of patients, 4 cases were in early CRF group and their mean duration of onset to CRF was 4.5 yews(8.9 years of age). Eight patients(67%) were in the conservative group and they had normal renal function for more than 10 years of age(mean duration of renal preservation was 10.6 years). The incidence of II type ACE gene were in 25.0%(3 cases), ID type in 41.7%(5 cases), DD type in 33.3%(4 cases). There was no significant difference between Alport patient and normal control(II type 44.3%, ID type 40.9%, DD type 14.8%). The incidence of DD type of early CRF group were higher than that of the conservative group(75% vs 12.5%)(p<0.05). There was no difference in ACE gene polymorphism between normal Alport family members and control group. Conclusion : Even though there was no significant difference of ACE polymorphism between Alport patients and the normal control group, the incidence of DD type is significantly increased in early CRF group which means DD type of ACE polymorphism has a possibility of being a predictor for early progression to CRF in Alport patients.

  • PDF

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

Correlation Between the Parameters of Radiosensitivity in Human Cancer Cell Lines (인체 암세포주에서 방사선감수성의 지표간의 상호관계)

  • Park, Woo-Yoon;Kim, Won-Dong;Min, Kyung-Soo
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.99-106
    • /
    • 1998
  • Purpose : We conducted clonogenic assay using human cancer cell lines (MKN-45, PC-14, Y-79, HeLa) to investigate a correlation between the parameters of radiosensitivity. Materials and Methods : Human cancer cell lines were irradiated with single doses of 1, 2, 3, 5, 7 and 10Gy for the study of radiosensitivity and subrethal damage repair capacity was assessed with two fractions of 5Gy separated with a time interval of 0, 1, 2, 3, 4, 6 and 24 hours. Surviving fraction was assessed with clonogenic assay using $Sperman-H\"{a}rbor$ method and mathematical analysis of survival curves was done with linear-quadratic (LQ) , multitarget-single hit(MS) model and mean inactivation dose$(\v{D})$. Results : Surviving fractions at 2Gy(SF2) were variable among the cell lines, ranged from 0.174 to 0.85 The SF2 of Y-79 was lowest and that of PC-14 was highest(p<0.05, t-test). LQ model analysis showed that the values of $\alpha$ for Y-79, MKN-45, HeLa and PC-14 were 0.603, 0.356, 0.275 and 0.102 respectively, and those of $\beta$ were 0.005, 0.016, 0.025 and 0.027 respectively. Fitting to MS model showed that the values of Do for Y-79. MKN-45, HeLa and PC-14 were 1.59. 1.84. 1.88 and 2.52 respectively, and those of n were 0.97, 1.46, 1.52 and 1 69 respectively. The $\v{D}s$ calculated by Gauss-Laguerre method were 1.62, 2.37, 2,01 and 3.95 respectively So the SF2 was significantly correlated with $\alpha$, Do and $\v{D}$. Their Pearson correlation coefficiencics were -0.953 and 0,993. 0.999 respectively(p<0.05). Sublethal damage repair was saturated around 4 hours and recovery ratios (RR) at plateau phase ranged from 2 to 3.79. But RR was not correlated with SF2, ${\alpha}$, ${\beta}$, Do, $\v{D}$. Conclusion : The intrinsic radiosensitivity was very different among the tested human cell lines. Y-79 was the most sensitive and PC-l4 was the least sensitive. SF2 was well correlated with ${\alpha}$, Do, and $\v{D}$. RR was high for MKN-45 and HeLa but had nothing to do with radiosensitivity parameters. These basic parameters can be used as baseline data for various in vitro radiobiological experiments.

  • PDF

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

Determination of the Optimum Sampling Area for the Benthic Community Study of the Songdo Tidal Flat and Youngil Bay Subtidal Sediment (송도 갯벌과 영일만 조하대 저서동물의 군집조사를 위한 적정 채집면적의 결정)

  • Koh, Chul-Hwan;Kang, Seong-Gil;Lee, Chang-Bok
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.1
    • /
    • pp.63-70
    • /
    • 1999
  • The optimum sampling area which can be applied to the benthic community study is estimated from large survey data in the Songdo tidal flat and subtidal zone of Youngil Bay, Korea. A total of 250 samples by 0.02 $m^2$ box corer for the benthic fauna in Songdo tidal flat and 50 samples by 0.1 $m^2$ van Veen grab in Youngil Bay were taken from the total sampling area of 5 $m^2$. It was assumed that the sampling area could contain sufficient information on sediment fauna, if cumulative number of species, ecological indices, and similarity index by cluster analysis reflect the similarity level of 75% to those found at total sampling area (5 $m^2$). A total of 56 and 60 species occurred from Songdo tidal flat and Youngil Bay, respectively. The cumulative curve of the species number ($N_{sp}$) as a function of the sampling area (A in $m^2$ ) was fitted as $N_{sp}=37.379A^{0.257}$ ($r^2=0.99$) for intertidal fauna and $N_{sp}=40.895A^{0.257}$ ($r^2=0.98$) for subtidal fauna. Based on these curves and 75% of similarity to the total sampling area (5 $m^2$), the optimum sampling area was proposed as 1.6 $m^2$ for the intertidal and 1.5 $m^2$ for the subtidal fauna. Ecological indices (species diversity, richness, evenness and dominance indices) were again calculated on the basis of species composition in differently simulated sample sizes. Changes in ecological indices with these sample sizes indicated that samplings could be done by collecting fauna from < 0.5 $m^2$-1.5 $m^2$ on the Songdo tidal flat and from < 0.5 $m^2$-1.2 $m^2$ in Youngil Bay. Changes in similarity level of all units of each simulated sample size showed that sampling area of 0.3 $m^2$ (Songdo tidal flat) and 0.6 $m^2$ (Youngil Bay) should be taken to obtain a similarity level of 75%. In conclusion, sampling area which was determined by cumulative number of species, ecological indices and similarity index by cluster analysis could be determined as 1.5 $m^2$ (0.02 $m^2$ box corer, n=75) for Songdo tidal flat and 1.2 $m^2$ (0.1 $m^2$ van Veen grab, n=12) for Youngil Bay. If these sampling areas could be covered in the field survey, population densities of seven dominant species comprising 68% of the total faunal abundance occurring on Songdo tidal flat and six species comprising 90% in Youngil Bay can be estimated at the precision level of P=0.2.

  • PDF

Evaluation of External Quality of Brand Soybeans (콩 시판 브랜드 제품의 외관 품질 평가)

  • Jong, Seung-Keun;Woo, Shun-Hee;Kim, Hong-Sig
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.52 no.3
    • /
    • pp.239-248
    • /
    • 2007
  • Although high nutritional values and continuous identification of important functional substances of soybean [Glycine max (L.) Merrill.] promote consumption of soybean products worldwide, informations on quality of brand soybean is not enough for consumers. Total of 100 brand soybeans [32 for soypaste and source, 45 black testa (lage), and 17 black testa (small) or medicinal soybean and beansprout soybean] were collected at supermarkets and several external quality factors were analyzed. Brand soybeans were marked with the environmental friendly and intimating words along with soybean (white or yellow), black soybean (black-, frost-, late frost-, green or inner-green-), medicinal soybean and beansprout soybean. Among 100 brand soybeans 30% was 1 kg package and 59% was 500 g package, difference between printed and actual weights of 70% brand soybeans was ${\pm}1%$ and weights of 2/3 of brand soybeans were higher than printed weight. Range of 100 seed weights of soypaste and source, black testa (large) and black testa (small) and beansprout soybeans were $23.7{\sim}47.8g$, $21.9{\sim}44.5g$ and $9.5{\sim}15.0g$, respectively. Although ranges of 100 seed weights of soypaste and source and black testa (large) soybeans were similar, 63% of soypaste and source were less than 29 g, while 78% of black testa (large) soybeans were higher than 30 g. Although average and highest percentages of seeds separated with 6.7 mm sieve were similar with 87.4% and 99.9% for soypaste and source soybean and 86.5% and 99.5% for black testa (large) soybean, respectively, the lowest percentages were 70.7% for soypaste and source soybean and 14.4% for black testa (large) soybean. When 100 seed weight was greater than 35 g, 90% of seeds were remained on 6.7 mm sieve. On the other hand 100 g weight and percentage of seeds remained on 6.7 mm sieve showed significantly positive correlations [r=0.7488** for soypaste and source soybean and r=0.7874** for black testa (large) soybean when 100 seed weight was $20{\sim}30g$. Based on hilum color and/or appearance, 76% of brand soybeans collected (more than 90% in yellow testa soybeans) were found to be mixed more than 10% with other cultivars or landraces. Foreign materials such as sand, piece of clothe, wood piece, dead insects, other soybeans were found in 20% of brand soybeans. Average test weight of brand soybeans was 762g $L^{-1}$ with a range of $645{\sim}820g\;L^{-1}$. Soybeans from local markets were as good as brand soybeans in 100 seed weight, uniformity of seeds, weight of foreign materials and test weight.

Adaptive RFID anti-collision scheme using collision information and m-bit identification (충돌 정보와 m-bit인식을 이용한 적응형 RFID 충돌 방지 기법)

  • Lee, Je-Yul;Shin, Jongmin;Yang, Dongmin
    • Journal of Internet Computing and Services
    • /
    • v.14 no.5
    • /
    • pp.1-10
    • /
    • 2013
  • RFID(Radio Frequency Identification) system is non-contact identification technology. A basic RFID system consists of a reader, and a set of tags. RFID tags can be divided into active and passive tags. Active tags with power source allows their own operation execution and passive tags are small and low-cost. So passive tags are more suitable for distribution industry than active tags. A reader processes the information receiving from tags. RFID system achieves a fast identification of multiple tags using radio frequency. RFID systems has been applied into a variety of fields such as distribution, logistics, transportation, inventory management, access control, finance and etc. To encourage the introduction of RFID systems, several problems (price, size, power consumption, security) should be resolved. In this paper, we proposed an algorithm to significantly alleviate the collision problem caused by simultaneous responses of multiple tags. In the RFID systems, in anti-collision schemes, there are three methods: probabilistic, deterministic, and hybrid. In this paper, we introduce ALOHA-based protocol as a probabilistic method, and Tree-based protocol as a deterministic one. In Aloha-based protocols, time is divided into multiple slots. Tags randomly select their own IDs and transmit it. But Aloha-based protocol cannot guarantee that all tags are identified because they are probabilistic methods. In contrast, Tree-based protocols guarantee that a reader identifies all tags within the transmission range of the reader. In Tree-based protocols, a reader sends a query, and tags respond it with their own IDs. When a reader sends a query and two or more tags respond, a collision occurs. Then the reader makes and sends a new query. Frequent collisions make the identification performance degrade. Therefore, to identify tags quickly, it is necessary to reduce collisions efficiently. Each RFID tag has an ID of 96bit EPC(Electronic Product Code). The tags in a company or manufacturer have similar tag IDs with the same prefix. Unnecessary collisions occur while identifying multiple tags using Query Tree protocol. It results in growth of query-responses and idle time, which the identification time significantly increases. To solve this problem, Collision Tree protocol and M-ary Query Tree protocol have been proposed. However, in Collision Tree protocol and Query Tree protocol, only one bit is identified during one query-response. And, when similar tag IDs exist, M-ary Query Tree Protocol generates unnecessary query-responses. In this paper, we propose Adaptive M-ary Query Tree protocol that improves the identification performance using m-bit recognition, collision information of tag IDs, and prediction technique. We compare our proposed scheme with other Tree-based protocols under the same conditions. We show that our proposed scheme outperforms others in terms of identification time and identification efficiency.