• Title/Summary/Keyword: 능동구조음향제어

Search Result 29, Processing Time 0.026 seconds

Study on Sound Reflection Control using an Active Sound Absorber (능동흡음재를 이용한 음파반사 제어기법 연구)

  • Chang, Woo-Suk;Gweon, Dae-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.806-814
    • /
    • 2009
  • This paper reviews a study about sound reflection control using an active sound absorber. An active sound absorber includes sound transmitting and receiving piezocomposite sensor layers molded by water tight epoxy, and connected with a feedback controller. The multi-layer sensors and the controller consists a closed feedback loop, whose intrinsic characteristics shows excellent impedance matching performance within specified frequency band, and consequently, minimizes reflection waves. Multilayer sound transmission model is derived based on one dimensional model, and its performance is verified with experiment using a pulse tube setup.

Active Noise Control Algorithm Based on a Delayless Subband Adaptive Filter Architecture (시간 지연 없는 서브밴드 적응 필터 구조를 사용한 능동 소음 제어 알고리듬)

  • 윤정현;박영철;윤대희;차일환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.52-58
    • /
    • 1998
  • 본 논문에서는 시간 지연이 없는 서브밴드 필터 구조를 사용한 능동 소음 제어 시 스템을 제안하였다. 제안된 시스템은 기준 입력 신호와 2차 경로의 전달 함수를 컨볼루션하 여 만들어지는 filtered reference 신호가 서브밴드내에서 생성될 수 있도록, 2차 소음원과 오차 센서 사이의 전기·음향학적인 경로를 나타내는 2차 전달 함수를 각 서브밴드로 재구 성함으로써, 알고리듬 구현시 계산량을 감소시킨다. 또한 2차 경로의 전달함수가 시간에 따 라 변화하는 경우에도 능동 소음 제어 시스템의 소음 제어 성능을 유지할 수 있도록, 각 밴 드마다 두 개의 적응필터를 사용한 on-line 시스템 인지 구조를 제안하여 on-line 시스템 인 지에 필요한 계산량을 감소시켰다. 본 논문에서 제시한 능동 소음 제어 시스템의 제어 성능 과 on-line 시스템 인지 성능을 모의 실험을 통하여 검증하였다.

  • PDF

Active Noise Control in Finite Duct by the FIR Filter Modelling Considering the Stuructural Characteristics (구조적특성을 고려한 유한 덕트계의 FIR필터모델링에 의한 능동소음제어)

  • Lee, Tae-Yeon;Song, Won-Shik;Oh, Jae-Eung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.59-67
    • /
    • 1992
  • Recently, the problem which actively control the unwanted noise propagated from the technical structure by the generated secondary sound has become considerable topic from the environmental preservation point of view. In most of these studies, active noise control deals with a plane wave propagation at low frequency using adaptive filtering techniques. On the other hand, in real acoustic systems are mostly short due to the limitation of geometric configuration. In this case, the acoustic properties such as reflections and resonances inside the acoustic system should be considered. In this paper, the acoustic modeling method for short length duct was introduced using the transfer matrix method, and the active noise control problem was investigated with \implementation of FIR filter for the transfer function of control system derived from this modeling method. The identification methods for the acoustic model of actual control system was proposed by numerical computation technique based on the estimation of optimal FIR filter coefficients. The acceptable attenuation on the real acoustic system and stability of the controller are predicted in this computational simulation.

  • PDF

Active Structural Acoustic Control for Reduction of Radiated Sound from Structure (구조물에서 방사되는 소음을 저감하기 위한 능동구조음향제어)

  • O, Jae-Eung;Hong, Jin-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1410-1415
    • /
    • 2001
  • Active control of sound radiation from a vibrating rectangular plate by a steady-state harmonic point force disturbance is experimentally studied. Structural excitation is achieved by two piezoceramic actuators mounted on the panel. Two accelerometers are implemented as error sensors. Estimated radiated sound signals using vibro-acoustic path transfer function are used as error signals. The vibro-acoustic path transfer function represents system between accelerometers and microphones. The approach is based on a multi-channel filtered-x LMS algorithm. The results shows that attenuation of sound levels of 11dB, 10dB is achieved.

Active Structural Acoustic Control for Radiated Sound Reduction in Plate (평판에서의 방사소음 저감을 위한 능동구조음향제어)

  • Hong, Jin-Seok;Oh, Jae-Eung;Lee, You-Yub;Shin, Joon
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.608-612
    • /
    • 2000
  • Active control of sound radiation(using active structural acoustic control) from a vibrating rectangular plate by a steady-state harmonic point force disturbance is experimentally studied. Control structural input are achieved by two piezoceramic actuators bonded to the surface of the panel. Two accelerometers are implemented as error sensors. Estimated radiated sound signals using vibro-acoustic path transfer function are used as error signals. The vibro-acoustic path transfer function represents system between accelerometers and microphones. The control approach are based on a multi-channel filtered-x LMS algorithm. The results demonstrate that attenuation of sound levels of 3dB, 13dB are achieved.

  • PDF

Modeling of Secondary Path in an Active Noise Control Using Time Delay Neural Network (시간 지연 신경 회로망을 이용한 능동 소음 제어 시스템의 2차 경로 모델링)

  • 이병도;이민호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.8
    • /
    • pp.19-24
    • /
    • 1998
  • 이 논문에서는 능동 소음 제어 시스템을 구성하는 요소들인 증폭기와 저주파 필터 와 같은 소자들의 비선형 특성과 공간에서의 주파수 대역에 따른 비선형 특성을 보상하여, 보다 효과적인 능동 소음 제어기를 설계하기 위해 시간 지연 신경 회로망을 이용하는 새로 운 방법을 제안한다. 공간을 포함한 2차 경로 함수를 모델링하여 보다 나은 성능을 갖는 능 동 소음 제어기를 구성하기 위한 기존의 최소 자승 오차 알고리듬에 기반한 filtered-x least mean square(LMS) 알고리듬과 오차 역전달 학습 알고리듬을 갖는 시간 지연 다층 구조 인 식자를 이용한 결과를 간단한 실험을 통하여 그 성능을 비교 분석한다.

  • PDF

A Double Loop Control Model Using Leaky Delay LMS Algorithm for Active Noise Control (능동소음제어를 위한 망각형 지연 LMS 알고리듬을 이용한 이중루프제어 모델)

  • Kwon, Ki-Ryong;Park, Nam-Chun;Lee, Kuhn-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.28-36
    • /
    • 1995
  • In this paper, a double loop control model using leaky delay LMS algorithm are proposed for active noise control. The proposed double loop control model estimates the loudspeaker characteristic and the error path transfer function with on-line using only gain and acoustic time delay to reduce computation burden. The control of error signal through double loop control scheme makes the more robust cntrol system. The input signal of filter to estimate acoustic time delay is used difference between input signal of input microphone and adaptive filter output. And also, in nonstationary environments, the leaky delay LMS algorithm is employed to counteract parameter drift of delay LMS algorithm. For practical noise signal, the proposed double loop control model reduces noise level about 12.9 dB.

  • PDF

Multiple Vibration Control of a Trim Panel to Reduce Structure-borne Noise (구조 소음저감을 위한 격자 패널의 다중 진동제어)

  • Kim, In-Soo;Kim, Yeung-Shik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.153-163
    • /
    • 1999
  • 본 연구에서는 격자패널을 통한 소음전달을 감소시키기 위하여 외부 구조적 가진으로부터 유발된 경량 패널의 진동을 능동 제어하는 기법을 기술한다. 최적 되먹임제어기와 적응 앞먹임제어기가 결합된 혼합형 제어기가 진동제어기로 사용된다. 되먹임제어기는 주파수 영역의 모델규명법에 의해 추출된 다중 입/출력 패널진동계 모델에 대하여 LQG 최적기법을 이용하여 감쇠능을 향상시키도록 설계된다. 앞먹임제어기는 되먹임 궤환의 결합효과를 자동적으로 보정할 수 있는 제안된 학습법칙에 기초하여 패널의 잔류진동이 최소가 되도록 적응된다. 45.7${\times}$45.7${\times}$2.54 ${cm^3}$ 벌집형상의 고강도 패널, 4개의 관성형 구동기 및 이산신호처리장치에 의해 구현된 패널 진동계에 대한 능동제어 실험을 수행해 본 결과 600Hz 주파수대역에 대한 12dB 진동저감이 이루어 질 수 있었다.

  • PDF

Secondary Path Estimation Algorithm Based on Residual Music Canceller for Noise Cancelling Headphone (노이즈 캔슬링 헤드폰에 적합한 잔여 음악 제거기 기반의 2차 경로 추정 알고리즘)

  • Ji, Youna;Lee, Keunsang;Park, Youngcheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.377-384
    • /
    • 2015
  • An active noise control (ANC) algorithm for noise canceling headphone is proposed. In this study, the feedback ANC operated with the filtered-x least mean square algorithm (FxLMS) algorithm is used to attenuate the undesired noise. Also an adaptive residual music canceller (RMC) is proposed for enhancing the accuracy of the reference signal of the feedback ANC. Simulation results show that a high quality of music sound can be consistently achieved in a time-varying secondary path situation.