A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing (천장 개방형 RT 사용시설의 방사선 안전성 평가 연구)

  • Sung-Hoe, Heo;Won-Seok, Park;Seung-Uk, Heo;Byung-In, Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.741-749
    • /
    • 2022
  • Radiography-Testing that verify the quality of welding structures without destruction are overwhelmingly used in industries, but many safety precautions are required as radiation is used. The workers for Radiography-Testing perform the inspection by moving the Iridium-192 radiation source embedded in the transport container of the gamma-ray irradiator within or outside the facility. The general facility is completely blocked about radiation from the outside with thick concrete, but if it is difficult for worker to handle object of inspection, facilities ceiling can be opened. A general facility may be constructed using a theoretical dose evaluation method because all exterior facilities are blocked, but if the ceiling is open, it is not appropriate to evaluate radiation safety with a simple theoretical calculation method due to the skyshine effect. Therefore, in this study, the radiation safety of the facility was evaluated in the actual field through an ion chamber survey-meter and an accumulated dose-meter called as OSLD, and the actual evaluation environment was modeled and evaluated using the Monte Carlo simulation code as FLUKA. According to the direction of the irradiation, the radiation dose at the facility boundary was difficult to meet the standards set by the regulatory authority, and radiation safety could be secured through additional methods. In addition, it was confirmed that the simulation results using the Iridium-192 source were valid evaluation with the actual measured results.

Treatment Planning for Minimizing Carotid Artery Dose in the Radiotherapy of Early Glottic Cancer (조기 성문암의 방사선치료에서 경동맥을 보호하기 위한 치료 계획)

  • Ki, Yang-Kan;Kim, Won-Taek;Nam, Ji- Ho;Kim, Dong-Hyun;Lee, Ju-Hye;Park, Dal;Kim, Don-Won
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.115-120
    • /
    • 2011
  • Purpose: To examine the feasibility of the treatment planning for minimizing carotid artery dose in the radiotherapy of early glottic cancer. Materials and Methods: From 2007 to 2010, computed tomography simulation images of 31 patients treated by radiotherapy for early glottic cancer were analyzed. The virtual planning was used to compare the parallel-opposing fields (POF) with the modified oblique fields (MOF) placed at angles to exclude the ipsilateral carotid arteries. Planning target volume (PTV), irradiated volume, carotid artery, and spinal cord were analyzed at a mean dose, $V_{35}$, $V_{40}$, $V_{50}$ and with a percent dose-volume. Results: The beam angles were arranged 25 degrees anteriorly in 23 patients and 30 degrees anteriorly in 8 dose-volume of carotid artery shows the significant difference (p<0.001). The mean doses of carotid artery were 38.5 Gy for POF and 26.3 Gy for MOF and the difference was statistically significant (p=0.012). Similarly, $V_{35}$, $V_{40}$, and $V_{50}$ also showed significant differences between POF and MOF. Conclusion: The modified oblique field was respected to prevent a carotid artery stenosis and reduce the incidence of a stroke based on these results.

The Analysis of Radiation Exposure of Hospital Radiation Workers (병원 방사선 작업 종사자의 방사선 피폭 분석 현황)

  • Jeong Tae Sik;Shin Byung Chul;Moon Chang Woo;Cho Yeong Duk;Lee Yong Hwan;Yum Ha Yong
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.157-166
    • /
    • 2000
  • Purpose : This investigation was peformed in order to improve the health care of radiation workers, to predict a risk, to minimize the radiation exposure hazard to them and for them to realize radiation exposure danger when they work in radiation area in hospital. Methods and Materials : The documentations checked regularly for personal radiation exposure in four university hospitals in Pusan city in Korea between January 1, 1993 and December 31, 1997 were analyzed. There were 458 persons in this documented but 111 persons who worked less then one year were excluded and only 347 persons were included in this study. Results : The average of yearly radiation exposure of 347 persons was 1.52$\pm$1.35 mSv. Though it was less than 50mSv, the limitaion of radiation in law but 125 (36%) people received higher radiation exposure than non-radiation workers. Radiation workers under 30 year old have received radiation exposure of mean 1.87$\pm$1.01 mSv/year, mean 1.22$\pm$0.69 mSv between 31 and 40 year old and mean 0.97$\pm$0.43 mSv/year over 41year old (p<0.001). Men received mean 1.67$\pm$1.54 mSv/year were higher than women who received mean 1.13$\pm$0.61 mSv/year (p<0.01). Radiation exposure in the department of nuclear modicine department in spite of low energy sources is higher than other departments that use radiations in hospital (p<0.05). And the workers who received mean 3.59$\pm$1.81 msv/year in parts of management of radiation sources and injection of sources to patient receive high radiation exposure in nuclear medicine department (p<0.01). In department of diagnostic radiology high radiation exposure is in barium enema rooms where workers received mean 3.74$\pm$1.74 mSv/year and other parts where they all use fluoroscopy such as angiography room of mean 1.17$\pm$0.35 mSv/year and upper gastrointestinal room of mean 1.74$\pm$1.34 mSv/year represented higher radiation exposure than average radiation exposure in diagnostic radiology (p<0.01). Doctors and radiation technologists received higher radiation exposure of each mean 1.75$\pm$1.17 mSv/year and mean 1.50$\pm$1.39 mSv/year than other people who work in radiation area in hospital (p<0.05). Especially young doctors and technologists have the high opportunity to receive higher radiation exposure. Conclusions : The training and education of radiation workers for radiation exposure risks are important and it is necessary to rotate worker in short period in high risk area. The hospital management has to concern health of radiation workers more and to put an effort to reduce radiation exposure as low as possible in radiation areas in hospital.

  • PDF

A Research on Improvement Measures for Safety Management of Aviation Cosmic Radiation (항공부문 우주방사선의 안전관리 적용을 위한 개선연구)

  • Choi, Sung-Ho;Lee, Jin;Kim, Hyo-Joong
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.31 no.2
    • /
    • pp.215-236
    • /
    • 2016
  • This paper is related to a study on safety management of cosmic radiation in the aviation area, and as a comprehensive study encompassing not only aviation crew but also aviation traffic users, presents issues on an exposure to the cosmic radiation which authors predict may be intensified in a time to come. Although the government of the Republic of Korea has recently activated regulations related to the cosmic radiation, the following improvement measures are further urged to be carried out not only as a regulatory improvement for pushing ahead with effectiveness but also as a supplementary tool. Firstly, a dose limit corresponding to the international standard needs to be applied. Since the dose limit imposed by the Korean government is improperly higher than the international dose limit of the cosmic radiation, the present dose limit needs to be re-established in a range of "not exceeding the international recommendation". Secondly, a new methodology is needed such that aviation companies observe a yearly effective dose limit of passengers. A fact that only aviation crew is specified but passengers are excluded in the related regulation is based on a recommendation presented by the International Commission on Radiological Protection (ICRP). According to the recommendation, Korean government excluded passengers in the "Cosmic Radiation Safety Requirements for Crew". Among the present aviation regulations, there exists a protection standard for protecting aviation traffic users. However, it presents a damage protection only for ticket-related issues. Since this regulatory weakness provides a cause of endangering national health, the authors believe that an improvement in the regulation is needed without sticking to the recommendation from the ICRP. To this end, new regulations are strongly demanded from aspects of not only legal but also regulatory areas. The dose limit in accordance with the international standard is established. However, at least a minute amount of cosmic radiation is continuously acting on all people of Korea. Since more and higher level of cosmic ration may exist in the aviation space, an improved method of representing the minute amount of cosmic radiation in figures. As a result, a desirable regulation may be established for protecting not only crew but also aviation traffic users from being exposed to the cosmic radiation via a legislation of the desirable regulation.

Perception of Risk and Using Status of Hand-Held Dental X-Ray Unit (이동형 치과 X선 발생장치 사용실태와 위험지각)

  • Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.442-447
    • /
    • 2014
  • The aim of this study was to analyze perception of risk and using status of hand-held dental x-ray unit among dental hygienists in metropolitan area. This research was based on perception of risk and using status of hand-held dental x-ray unit survey in 257 dental hygienists from July 7 to 31, 2014. Data were analyzed with t-test, one way ANOVA, and multivariable logistic regression analysis using SPSS Windows 21.0 program and significance level was set at p<0.05. The hand-held dental x-ray unit to cover all type patients was 24.8%. The 62.6% of patients and 81.3% of operator doesn't wear lead apron, the experience rate of radiation education was 40.1%. The average of risk perception was 3.08 points. The associated factors of risk perception were career, number of radiation exposure per day, and possession of fixed x-ray unit. The increased of accumulated dose when the occupationally exposed work continues, it is necessary to effort of defense against dental radiation.

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge (가상쐐기와 기존쐐기의 물리적 특성 비교)

  • Choi Dong-Rak;Shin Kyung Hwan;Lee Kyu Chan;Kim Dae Yong;Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyun;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.78-83
    • /
    • 1999
  • Purpose : We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. Materials and Methods : We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60$^{\circ}$) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15cm${\times}$20cm radiation field size at the depth of loom. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15cm H20cm and a polystyrene phantom was used. Results : For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%) , respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5$^{\circ}$ . Suface dose with physical wedge was reduced by maximum 20% (x-ray beam :6 MV, wedge angle:45$^{\circ}$, 550: 80 cm) relative to one with virtual wedge or without wedge. Conclusions : Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge.

  • PDF

Radiological Safety Assessment of a HLW Repository in Korea using MASCOT-K (MASCOT-K를 이용한 가상 방사성폐기물 처분장에서의 종합성능 평가)

  • 황용수;이연명;강철형
    • Tunnel and Underground Space
    • /
    • v.10 no.4
    • /
    • pp.553-558
    • /
    • 2000
  • Since 1977, KAERI has conducted the fundamental R&D on the permanent disposal of potential HLW repository in Korea. The first ten year project is divided into three short-term phase studies. The first phase study which shall be finished in March of 2000, has the prime target to develop the disposal concept of HLW. Throughout this study the preliminary and generic disposal repository system has been introduced. The potential repository is proposed to be emplaced into crystalline rocks which is the most common rock types in Korea. The proposed depth of the repository is between 300 to 700 meter. The numerical code, MASCOT-K was developed to asserts the long term safety of the proposed repository concept. Based on this conceptual design preliminary safely assessment was performed. Results show that for the given disposal system the potential radioactive release it well below the regulatory limit.

  • PDF

A study on the strategies to lower technologist occupational exposure according to the performance form in PET scan procedure (PET 검사실 종사자의 업무 행위 별 방사선피폭 조사에 따른 피폭선량 저감화를 위한 연구)

  • Ko, Hyun Soo;Kim, Ho Sung;Nam-Kung, Chang Kyeoung;Yoon, Soon Sang;Song, Jae Hyuk;Ryu, Jae Kwang;Jung, Woo Young;Chang, Jung Chan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.17-29
    • /
    • 2015
  • Purpose For nuclear medicine technologists, it is difficult to stay away from or to separate from radiation sources comparing with workers who are using radiation generating devices. Nuclear medicine technologists work is recognized as an optimized way when they are familiar with work practices. The aims of this study are to measure radiation exposure of technologists working in PET and to evaluate the occupational radiation dose after implementation of strategies to lower exposure. Materials and Methods We divided into four working types by QC for PET, injection, scan and etc. in PET scan procedure. In QC of PET, we compared the radiation exposure controlling next to $^{68}Ge$ cylinder phantom directly to controlling the table in console room remotely. In injection, we compared the radiation exposure guiding patient in waiting room before injection to after injection. In scan procedure of PET, we compared the radiation exposure moving the table using the control button located next to the patient to moving the table using the control button located in the far distance. PERSONAL ELECTRONIC DOSEMETER (PED), Tracerco$^{TM}$ was used for measuring exposed radiation doses. Results The average doses of exposed radiation were $0.27{\pm}0.04{\mu}Sv$ when controlling the table directly and $0.13{\pm}0.14{\mu}Sv$ when controlling the table remotely while performing QC. The average doses of exposed radiation were $0.97{\pm}0.36{\mu}Sv$ when guiding patient after injection and $0.62{\pm}0.17{\mu}Sv$ when guiding patient before injection. The average doses of exposed radiation were $1.33{\pm}0.54{\mu}Sv$ when using the control button located next to the patient and $0.94{\pm}0.50{\mu}Sv$ when using the control button located in far distance while acquiring image. As a result, there were statistically significant differences(P<0.05). Conclusion: From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine. Conclusion From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine.

  • PDF

Reliability Evaluation of ACP Component under a Radiation Environment (방사선환경에서 ACP 주요부품의 신뢰도 평가)

  • Lee, Hyo-Jik;Yoon, Kwang-Ho;Lim, Kwang-Mook;Park, Byung-Suk;Yoon, Ji-Sup
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.4
    • /
    • pp.309-322
    • /
    • 2007
  • This study deals with the irradiation effects on some selected components which are being used in an Advanced Spent Fuel Conditioning Process (ACP). Irradiation test components have a higher priority from the aspect of their reliability because their degradation or failure is able to critically affect the performance of an ACP equipment. Components that we chose for the irradiation tests were the AC servo motor, potentiometer, thermocouples, accelerometer and CCD camera. ACP facility has a number of AC servo motors to move the joints of a manipulator and to operate process equipment. Potentiometers are used for a measurement of several joint angles in a manipulator. Thermocouples are used for a temperature measurement in an electrolytic reduction reactor, a vol-oxidation reactor and a molten salt transfer line. An accelerometer is installed in a slitting machine to forecast an incipient failure during a slitting process. A small CCD camera is used for an in-situ vision monitoring between ACP campaigns. We made use of a gamma-irradiation facility with cobalt-60 source for an irradiation test on the above components because gamma rays from among various radioactive rays are the most significant for electric, electronic and robotic components. Irradiation tests were carried out for enough long time for total doses to be over expected threshold values. Other components except the CCD camera showed a very high radiation hardening characteristic. Characteristic changes at different total doses were investigated and threshold values to warrant at least their performance without a deterioration were evaluated as a result of the irradiation tests.

  • PDF