• Title/Summary/Keyword: 누설 검출

Search Result 183, Processing Time 0.022 seconds

A study on the amorphous s-i-n photodiode integrated with CMO IC (CMOS IC와 집적 가능한 비정질 p-i-n 광 수신기 제작에 관한 연구)

  • Kwak, Chol-Ho;Yoo, Hoi-Jun;Jang, Jin;Moon, Byoung-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.500-505
    • /
    • 1997
  • Experimental amorphous photodiode is fabricated on CMOS IC using a-Si:H p-i-n structure. Amorphous photodiode is scuccessfully integrated on CMOS IC using amorphous Si produced by PECVD system. The PECVD system can deposit a-Si:H at low temperature so that photodiode can be integrated with CMOS IC structure without any process incompatibility. The fabricated amorphous photodiode has a breakdown voltage of below -20 V, a leakage current of about 1 $\mu\textrm{A}$, and turn-on voltage of 0.6~0.8 V. It is demonstrated that the photocurrent of optical signal can be turned on and off by a small voltage and the fabricated amorphous p-i-n photodiode can be used as an optical switch.

  • PDF

The Convergence Application Example of Non-destructive Inspection System (비파괴 검사 시스템의 융합 적용 사례)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.191-197
    • /
    • 2017
  • This development is for non-destructive machine using X-Ray source about detecting outline faults of below middle size products. The differentiation is product of research and development unspecialized small and medium-sized products using X-Ray light sources can check real time if the surface of an external fault of radiation dose reference, within the leakage. The speed control is possible by software solution. In addition, we're working on possibly block doors for worker safety and equipment at the same time that inner drive can be identified in the image. These principles, as a key enabler of the current inspection system such as the container is small to medium-sized parts - a long way from utilization level is possible. This research will give rise to major effects for other various non-destructive market industries except car-industry. The most important fact is that this developed non-destructive machine is controlled below $0.2micro-S{\mu}v$.

Development of Arc-Fault Detection Technique (아크고장 검출기술의 개발)

  • Lim, Young-Bae;Jeon, Jeong-Chay;Park, Chan-Eom;Bae, Seok-Myeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1810-1816
    • /
    • 2009
  • In 2007, 9,128 fires were actually caused by electrical faults and these fires resulted in 29 deaths and 262 injuries. Arc-faults were one of the major causes of these fires. When an unintended arc-fault occurs, it generates intense heat that can easily ignite surrounding combustibles. But, because conventional circuit breakers only respond to overloads, short circuits, and leakage currents, the breakers do not protect against arcing conditions. This paper presents results obtained in experiments on ignition behavior of wire by series arc fault currents and techniques developed to detect the arc-faults. The developed technique was tested after installation to make sure that they are working properly and protecting the circuit. If the developed arc fault detection technique is applied, the electrical fires caused by an arc-fault can be reduced.

Study for Development of Nondestructive Inspection Device in Natural Gas Pipeline Using MFL Technology (MFL을 이용한 천연가스 배관용 비파괴 검사장비 개발에 관한 연구)

  • Cho S.H.;Kim D.K.;Park D.J.;Park S.S.;Yoo H.R.;Koo S.J.;Rho Y.W.;Kho Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.10-16
    • /
    • 2002
  • This paper introduces developed prototype intelligent pig which detects corrosion on pipeline by using Magnetic Flux Leakage technology. The 8 inch developed MFL(Magnetic Flux Leakage) pig is composed of 5 yokes which magnetize pipeline wall and 45 Hall sensors which detect MFL signal. The designed MFL modules are analyzed by using magnetic circuit method in order to confirm whether pipeline wall is fully saturated. A variety of artificial defects are manufactured on 8 inch diameter steel pipeline in order to acquire MFL signals. So leakage flux of the axial, radial and circumferential component was acquired as defects. The results of this paper show that design technique for 8 inch MFL pig can be applied to large diameter MFL pig and 0.5mm defect depth can be detected.

  • PDF

The dark-current and X -ray sensitivity measurement of hybrid digital X-ray detector having dielectric layer structure (a-Se 기반의 혼합형 X-선 검출기에서 유전층의 누설전류 저감효과)

  • Seok, Dae-Woo;Park, Ji-Koon;Joh, Jin-Wook;Lee, Dong-Gil;Moon, Chi-Woong;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.31-34
    • /
    • 2002
  • In this paper, the electric properties of amophous selenium multilayer samples has been investigated. In order to develop the hybrid flat-panel digital· X-ray image detector, we measured and analyzed their performance parameters such as the X -ray sensitivity and dark-current for a amophous selenium multilayers X-ray detector with a phosphor layer, The hybrid digital X-ray image detector can be constructed by integrating a phosphor layer (or a scintillative layer) that convert X-ray to a light on a-Se photoconduction mulilayers that convert a light to electrical signal. As results, the dielectric materials such as parylene between the phosphor layer and the top electrode may reduce the dark-current of the samples. Amorphous selenium multilayers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the hybrid X-ray detector.

  • PDF

Design of Leakage Current Detecting Equipment of an Arrester Diagnostic Type in a Distribution Line (배전선로용 피뢰기 진단형 누설전류 검출장치 설계)

  • Yoon, Gi-Gab;Park, Jong-Beom;Yoon, Suk-Mu;Lee, Seung-Hak;Kim, Hong-Pil;Kim, Kwang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.501-503
    • /
    • 2000
  • Since an arrester has been generally used at the distribution line and abroad for the protection of electrical equipments against overvoltage (or abnormal surge) taking place in or from an electrical system, a fault, especially, in the distribution line is very likely to result in the destruction of insulation of other protection devices to cause an overall paralysis of a power system, a chaos. Considering the importance of arresters, its earlier replacement than its proposed life cycle causes an economical loss, and a negligence not to replace or repair it in time gives rise to a crucial accidence. The purpose of this paper is to invent an electric leakage current detector and to solve such problems by the continuous and regular inspection of an arrester.

  • PDF

An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line (전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발)

  • Kim, Dong-Wan;Park, Ji-Ho;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

Design and Implementation of a ZigBee Nework-based Integrated AFCI (지그비 네트워크 기반 복합형 AFCI 설계 및 구현)

  • Chang, Ki-Heung;Kim, Kee-Min;Kim, Jae-O;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.41-48
    • /
    • 2010
  • In this paper, a new type of integrated AFCI is designed and implemented by combining individual circuit breaker characteristics, which can effectively detect arc fault signals in real-time. The proposed integrated AFCI satisfies the UL1699, the USA certification standard, and the Korean circuit breaker standards such as KS C4613 and KS C8321. Data signals are transferred to the management server via ZigBee network to analyze dangerous factors and to prevent unwanted trip. It is also shown by experiments that arc fault signals are detected and analyzed by using the integrated AFCI with ZigBee networks.

The Fault Detection of an Air-Conditioning System by Using a Residual Input RBF Neural Network (잔차입력 RBF 신경망을 사용한 냉방기 고장검출 알고리즘)

  • Han, Do-Young;Ryoo, Byoung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.780-788
    • /
    • 2005
  • Two different types of algorithms were developed and applied to detect the partial faults of a multi-type air conditioning system. Partial faults include the compressor valve leakage, the refrigerant pipe partial blockage, the condenser fouling, and the evaporator fouling. The first algorithm was developed by using mathematical models and parity relations, and the second algorithm was developed by using mathematical models and a RBF neural network. Test results showed that the second algorithm was better than the first algorithm in detecting various partial faults of the system. Therefore, the algorithm developed by using mathematical models and a RBF neural network may be used for the detection of partial faults of an air-conditioning system.

Detection Algorithm and Characteristics on DC Residual Current based on Analysis of IEC60479 Impedance Model for Human Body (IEC60479 인체 임피던스 모델에 근거한 직류누설전류의 특성 및 검출 알고리즘)

  • Kim, Yong-Jung;Lee, Jinsung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.305-312
    • /
    • 2018
  • DC distribution systems has recently taken the spotlight. Concerns over human safety and stability facility are raised in DC distribution systems. Std. IEC 60479 provides basic guidance on "the effects of shock current on human beings and livestock" for use in the establishment of electrical safety requirements and suggests an electrical impedance of the human body. This study analyzes impedance spectrums based on the electrical equivalent impedance circuit for the human body; human body impedances measured by experiments are analyzed below the fundamental frequency (60 Hz). The analysis shows that the equivalent impedance circuit for the human body should be modified at least in low-frequency range below the fundamental frequency (60 Hz). The DC residual current detection method that can classify electric shock accidents of humans and electric leakages of facilities is proposed by applying the analysis result. The detection method is verified by experiments on livestock.