• 제목/요약/키워드: 누설시험

검색결과 268건 처리시간 0.029초

추진제 혼합 방지 실의 성능시험 (Performance Test of Inter-propellant Seal)

  • 곽현덕;전성민;김진한
    • Tribology and Lubricants
    • /
    • 제26권6호
    • /
    • pp.322-328
    • /
    • 2010
  • An inter-propellant seal (IPS) for 75 ton class thrust turbopump was tested. Leakage characteristics were presented with a given range of pressure difference under cryogenic as well as room temperature conditions. For cryogenic tests, liquid nitrogen was used as analogic fluid of liquid oxygen (LOX) while water was used instead of kerosene for room temperature condition. Test results showed that IPS had satisfactory leakage performance. Additionally endurance test was conducted to prove the life time of manufactured IPS and the tested IPS had successfully survived during required life time, 2100 seconds.

유압 피스톤모터용 Slipper Pad의 정압시험에 관한 연구 (A Study on the Hydrostatic Test of Slipper Pad for Hydraulic Piston Motor)

  • 함영복;김광영;김형의
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.645-649
    • /
    • 1997
  • In case of swash plate type axial piston hydraulic motor, hydrostatic bearing used to achieve the lubrication effect on the mechanical sliding contact areas between the following parirs ; sliooer-pad and swash plate,piston and cylinder bore,valve plate and cylinder block, etc. This study discussed the basic charateristic for the hydrostatic slipper-pad bearings with the capillary or orifice restrictor under static load condition. And, we also development of hydrostatic bearing tester for hydrostatic balancing test of pistion & slipper-pad assembly, and some experimental data on supply pressure step responce are reported.

  • PDF

충격햄머 가진으로 구한 주파수응답함수의 오차와 해결방법 (The errors and reducing method in the frequency response function from impact hammer testing)

  • 안세진;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.71-77
    • /
    • 2002
  • The spectrum of impulse response signal which is obtained from an impulse hammer testing is used for frequency response function, nevertheless it has serious faults when the record length for the signal processing is not very long. The faults cannot be avoided with the conventional signal analyzer that is processing all the signals as if they are always periodic. The signals generated by the impact hammer are undoubtedly non-periodic because of the damping, and are acquired for limited recording time due to the memory as well as the computation performance of the signal analyzer. This paper will make clear the relation between the faults and the length of recording time, and propose the way for solving the faults.

  • PDF

지능형 반도체 변압기용 다권선 고주파 변압기 설계 방안 (Design Methodology of Multi-winding High-frequency Transformer for Solid-state Transformer)

  • 박시호;류명효;김호성;차헌녕
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.306-307
    • /
    • 2018
  • 본 논문은 지능형 반도체 변압기 (Solid-state transformer, SST)용 다권선 고주파 변압기의 최적 설계 방안을 제안한다. 설계된 변압기는 10 kHz의 스위칭 주파수를 운전 조건으로 하며, 60 kVA의 정격 용량을 가진다. 특히 13.2 kV의 중전압 계통에 적용하기 위해 30 kV 이상의 절연 내력으로 설계하였으며, SST 시스템의 부피가 커지는 것을 억제하기 위해 3 입력-1 출력으로 구성된 4-권선 방식으로 구성하였다. 절연 내력을 만족시키기 위해 teflon PTFE를 이용한 내부 보빈과 외부 보빈 및 가드를 제작하였으며, 누설 인덕턴스 최소화 및 근접 효과와 표피 효과로 인한 AC 손실을 최소화하기 위해 쉘-타입으로 설계하였다. 시제품 제작 후 60 kVA의 정격 하에 동작 검증을 완료하였으며, 내전압 시험을 이용하여 30 kV급의 절연 내력을 검증하였다.

  • PDF

100kHz 고밀도 펄스 변압기 설계 (100kHz Higy Density Pulse Transformer Design)

  • 김성철;박성수;김상희;김도태;남상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1283-1285
    • /
    • 2000
  • 고 주파수 스위칭 동작을 하는 DC/DC 컨버터 혹은 인버터를 효율적으로 제작하기 위하여 고주파용 펄스 변압기의 역할은 매우 중요하다. 동작주파수가 수십 혹은 수백 kHz일 경우에는 최소의 부피로 충분한 전력을 수용하면서 변압기를 설계 및 제작하기 위하여 코어 및 권선의 선정, 코어 및 권선의 손실, 변압기의 온도상승요소, 변압기의 발열, 변압기의 누설 인덕턴스, 권선 케페시턴스, 분포 케페시턴스 그리고 공진주파수 등을 고려하여 설계하고 시험 평가하여야 한다. 본 논문에서는 위의 여러가지 요소들을 고려하여 동작주파수가 100kHz인 DC/DC 컨버터 혹은 인버터를 고밀도 제작하기 위하여 고주파용 펄스변압기를 최소의 부피로 수kW 용량으로 변압기의 온도상승요소를 고려하여 설계, 제작 그리고 실험한 결과에 대하여 기술 하고자 한다.

  • PDF

고성능 씰리스 실린더의 해석 및 누설유량 시험 (An Analysis and Test for Leakage Flow of Sealless Cylinder)

  • 김성종;김동수;이승현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.961-966
    • /
    • 2004
  • The cylinder without seal has a piston with air bearing which is partly cylindrical and conical shape. The description of system geometry is deviation by the flow rate equation. Then pressure distribution and bearing force equations are derived. Several non-dimensional parameters are suggested. The relationship among bearing force, leakage flow and geometry of the bearing is investigated by simulation. And determination method for optimal design of sealless cylinder is given. A prototype of sealless cylinder which had rod bearing with four pockets, five pockets, and six pockets was built respectively. As a result of leakage flow test, it is evaluation to air bearing in sealless cylinder.

  • PDF

송전용 애자의 인공오손시험 기법과 누설전류 특성 (Artificial contaminated test method and leakage current characteristics of EHV insulators)

  • 최인혁;정윤환;최장현;이동일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.386-391
    • /
    • 2004
  • To find out the reason of accident by being stained of insulators, this paper researched and analyzed the result of electrical characteristic test and field test of EHV insulator through artificial contaminated method. The best way to evaluate contaminated level of insulator surface is getting a contamination data by regional groups continually. But it is needed a lot of time and manpower. To overcome those difficulties, this research introduced ESDD(equivalent salt deposit density) measurement method which is adapted to the international codes of IEC and compared the relation between experimental test results which contaminated insulators by going through stain procedure and electrical measurement results.

  • PDF

가속열화시험에 의한 18kV ZnO 피뢰기의 누설 전류 특성 분석 (Leakage Current Characteristics of 18kv ZnO Lightning Arresters by Accelerated Aging Test)

  • 김주용;송일근;김찬영;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.62-67
    • /
    • 2002
  • This paper provides the results of accelerated aging test of 18kV ZnO lightning arresters to investigate the leakage current characteristics. It was impossible to establish the replacement criterion for field operating lightning arrester because conventional aging test was only focused on the aging of ZnO elements. In general, it is possible to replace the aged arresters before the failure in the field using the leakage current measurement because it must be increased by the aging. But we can not use the method because we don't know the characteristics of the installed lightning arresters. Therefore in this paper we applied operating voltage and accelerating cycle which consists of temperature and humidity to the arresters. Then we measured the variation of total and resistive leakage current and found out the characteristics of the acted lightning arresters.

결합 인덕터와 배압 회로를 이용한 고승압 직류전원장치 (High boost DC Power supply Using Coupled inductor and Voltage multiplier)

  • 금재범;백주원;김종현;류명효;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.296-298
    • /
    • 2007
  • 신재생에너지원의 하나인 연료전지 시스템이나 배터리 백업용 전력변환 회로는 많은 응용분야에서 고승압 직류변환장치의 구조로 낮은 입력전압을 높은 출력전압으로 승압한다. 이를 위한 고승압회로의 여러 가지 방식중에서 다단으로 직렬 접속된 구조의 직류변환장치는 복잡하고 비용이 큰 단점이 있다. 또한 높은 출력전압을 얻을 수 있는 플라이백 직류전원장치는 누설성분에 의해 손실이 크므로 효율이 낮고 소자의 스트레스가 큰 단점이 있다. 본 논문에서는 배압회로와 결합 인덕터를 이용한 고승압 전원장치를 제안한다. 제안하는 회로는 24V입력에서 300V로 승압한다. 결합 인덕터의 이차 전압은 배압회로에 의해 정류되고 인덕터의 일차측 승압전압과 병렬로 연결되어 출력전압을 만든다. 높은 승압전압이 낮은 듀티사이클로도 얻어지는 제안 회로는 이론적인 해석과 100W 실험장치를 통해 시험하며 그 타당성을 검증한다.

  • PDF

송전용 폴리마 런자의 장기성능을 위한 복합열화시험 (Multi-aging Test for Estimating Long Time Performance of Polymer Insulators for Transmission line)

  • 조한구;한세원;이운용;윤문수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.640-643
    • /
    • 1999
  • This paper presents the results of multi-stress chamber experiments done to examine the tracking and erosion performance of polymer insulator. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. Therefore, multi-stress testing is believed to a suitable test for evaluating the aging performance of polymer insulator designs. We have nvestigated IEC 61109 Annex C for estimating long time performance of polymer insulator.

  • PDF