A Study on the Prevention of the Electric Corrosion by Leakage Current using the Life of Sacrificial Anode Method (누설전류에서 희생양극법을 이용한 전식 방지에 대한 연구)

  • Yoo, Hai-Chool;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.21-26
    • /
    • 2010
  • Recently, since the prevalence of electric driving transfer system arouse the electric corrosion of neighboring underground metal establishment, the problems caused by that kind of electric corrosion became very serious. In this paper, we studied about a theoretical concept and concrete concepts of electric corrosion and tried suggested an optimistic chemico-electrical measures on the electric corrosion of underground metal establishments.

반도체 검출기의 절연 최적화를 위한 다층 절연막 평가

  • Park, Jeong-Eun;Myeong, Ju-Yeon;Kim, Dae-Guk;Kim, Jin-Seon;Sin, Jeong-Uk;Gang, Sang-Sik;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.372-372
    • /
    • 2014
  • 반도체 검출기는 입사되는 X선 에너지에 의하여 이온화되어 발생하는 전자 전공쌍을 수집함으로 방사선 정보를 확인하는 선량계로써 많은 연구와 활용이 이루어지고 있다. 하지만, X선 에너지에 의하여 반도체 검출기에서 발생하는 전기적 신호량이 높지 않기 때문에 누설 전류의 저감이 필수적이다. 누설 전류를 저감시키기 위한 방안으로 반도체 층과 전극 층의 Schottky Contact 구조의 설계, Insulating Layer의 사용, 높은 비저항의 반도체 물질 연구 등이 이루어지고 있다. 하지만, 기존에 누설 전류 저감을 위하여 Insulating Layer를 전극층과 반도체 층 사이에 형성하는 연구에 있어서 Insulating Layer와 반도체 층의 계면 사이에서 발생하는 Charge Trapping으로 인하여 생성되는 신호의 Reproducibility 저하, 동영상 적용의 제한 등의 문제점을 겪어왔다. 이에 본 논문에서는 누설 전류를 저감시킴과 동시에 Charge Trapping의 최소화를 이루기 위하여 Insulating Layer의 두께 최적화 연구를 수행하였다. 본 연구에서 사용한 Insulating Layer는 검출기 표면에 입사하는 X선 정보 손실을 최소화 시키는 동시에 누설 전류와 Charge Trapping을 최소화 시키는 방법으로써 CVD방법으로 검출기 표면에 균일하게 Insulating Layer를 코팅하였다. Insulating 물질은 Parylene을 사용하였으며, 그 중 온도, 습도 등 외부환경에 영향을 적게 받는 type C를 사용하였다. 증착에 사용한 장비의 진공도는 Torr로 설정하여 증착되는 Parylene의 두께가 약 $0.3{\mu}m$가 되게 하였으며, 실험에는 반도체 물질 PbO를 사용하였다. Parylene의 절연 특성은 Dark Current와 Sensitivity를 측정한 SNR을 이용하여 Parylene코팅이 되지 않은 동일 반도체 검출기와의 신호를 비교하였으며 또한 Parylene를 다층 제작한 검출기의 수집 신호량을 비교하였다. 제작한 검출기의 X선 조사 시의 수집 전하량 측정 결과, 100 kVp, 100mA, 0.03s의 X선 조건에서 $1V/{\mu}m$의 기준 시, Parylene를 코팅하지 않은 PbO 검출기의 Dark current는 0.0501 nA/cm2, Sensitivity는 0.6422 nC/mR-cm2, SNR은 12.184이었으며, Parylene단층의 두께인 $0.3{\mu}m$로 증착된 시편의 Dark current는 0.04097 nA/cm2, Sensitivity는 0.53732 nC/mR-cm2으로 Dark current가 감소되고 sensitivity도 감소하였지만 SNR은 13.1150으로 높아진 것을 확인할 수 있었다. Perylene이 $0.6{\mu}m$로 증착된 시편의 경우, Dark Current는 0.04064 nA/cm2, Sensitivity는 0.31473 nC/mR-cm2, SNR은 7.7443으로써 Insulating Layer가 없는 시편보다 SNR이 약 40% 낮아진 것을 확인할 수 있었다. Parylene이 $0.9{\mu}m$로 증착된 시편의 경우 Dark current는 0.0378 nA/cm2, Sensitivity 0.0461 nC/mR-cm2로 Insulating Layer가 없는 시편에 비해 SNR은 약 1/12배 감소한 1.2196이었고, Parylene이 $1.2{\mu}m$로 증착된 시편의 SNR은 1.1252로서 더 감소하였다. 따라서 Parylene을 다층 코팅한 검출기일수록 절연 효과의 영향이 커짐으로써 SNR 비교 시 수집되는 신호량이 줄어드는 것을 확인하였다. 반도체 검출기의 누설 전류를 저감시킴과 동시에 신호 수집율에 영향을 최소화시키기 위하여 Insulating Layer의 두께를 적절하게 설정하여 적용하면 Insulating Layer가 없는 검출기에 비해 누설전류를 최소한으로 줄일 수 있고 신호 검출효율이 감소하는 것을 방지할 수 있을 것이라 사료된다.

  • PDF

New Seat Design and Finite Element Analysis for Anti-Leakage of Globe Valve (글로브 밸브의 누설방지를 위한 시트 설계 및 유한요소해석)

  • Lee, Sung Ho;Kang, Gyeong Ah;Kwak, Jae-Seob;An, Ju Eun;Jin, Dong Hyun;Kim, Byung Tak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.1
    • /
    • pp.81-86
    • /
    • 2016
  • The valves used to control or shut off the flow through a pipeline can be divided into many different types, including gate valves, globe valves, and check valves. Globe valves, in particular, have excellent properties, and because they can easily control the flow under high-pressure conditions, they are generally used in LNG ship and steam pipelines. In this paper, a method for changing the shape of a seat was suggested to solve the valve leakage problem from a structural perspective. In addition, the stress distribution and directional deformation were compared for each model. The suggested models were thus validated, and the optimized seat structure, which includes a self-supporting capability for decreasing the amount of leakage, was determined.

A study on Electrical and Diffusion Barrier Properties of MgO Formed on Surface as well as at the Interface Between Cu(Mg) Alloy and $SiO_2$ (Cu(Mg) alloy의 표면과 계면에서 형성된 MgO의 확산방지능력 및 표면에 형성된 MgO의 전기적 특성 연구)

  • Jo, Heung-Ryeol;Jo, Beom-Seok;Lee, Jae-Gap
    • Korean Journal of Materials Research
    • /
    • v.10 no.2
    • /
    • pp.160-165
    • /
    • 2000
  • We have investigated the electrical and diffusion barrier properties of MgO produced on the surface of Cu (Mg) alloy. Also the diffusion barrier property of the interfacial MgO between Cu alloy and $SiO_2$ has been examined. The results show that the $150\;{\AA}$-MgO layer on the surface remains stable up to $700^{\circ}C$, preventing the interdiffusion of C Cu and Si in Si/MgO/Cu(Mg) structure. It also has the breakdown voltage of 4.5V and leakage current density of $10^{-7}A/\textrm{cm}^2/$. In addition, the combined structure of $Si_3N4(100{\AA})/MgO(100{\AA})$ increases the breakdown voltage up to lOV and reduces the leakage current density to $8{\tiems}10^{-7}A/\textrm{cm}^2$. Furthermore, the interfacial MgO formed by the chemical reac­t tion of Mg and $SiO_2$ reduces the diffusion of copper into $SiO_2$ substrate. Consequently, Cu(Mg) alloy can be applied as a g gate electrode in TFT /LCDs, reducing the process steps.

  • PDF

FEA(Finite Element Analysis) Study for Electronic Hydrogen Regulator of Confidentiality Improvement (전자식 수소레귤레이터 기밀성 향상을 위한 FEA 연구)

  • Son, Won-Sik;Song, Jae-Wook;Jeon, Wan-Jae;Kim, Seung-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.175-181
    • /
    • 2019
  • In the case of a conventional single stage decompression regulator used for large depressurization in the hydrogen fuel cell system of a fuel cell electric vehicle (FCEV), problems can arise, such as pulsation, slow response, hydrogen brittleness, leakage, high weight, and high cost due to high decompression. Most of these problems can be overcome easily using two decompression mechanisms (two-stage structures). In addition, a wide outlet-pressure control range can be secured if an electronic solenoid is applied to the second decompression. Accordingly, it is necessary to improve the precision of the outlet pressure of a two-stage pressure-reducing regulator and develop techniques, such as leakage prevention, durability, light weight, and price reduction. Therefore, to improve the outlet pressure accuracy and prevent leakage, the structural part before and after decompression to improve the air tightness were divided and the analysis was carried out assuming that the valve part was closed (open ratio: 0%) after each initial internal pressure application.

Arc Detection and Interruption Algorithm Design for Fire Protection (화재 방지를 위한 아크전류 검출 제어기 설계)

  • Ban, Gi-Jong;Won, Young-Jin;Lim, Seung-Ha
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.19-24
    • /
    • 2005
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc current controller does not have the arc current interrupt function. Hence, Controller of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

지능형 보안망의 개발

  • 김영창;김영민;안형일;김응식
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.82-87
    • /
    • 2000
  • 최근 들어 산업설비 및 건축물의 대형화, 다 기능화 추세가 두드러지게 나타나고 있는 가운데 외부침입에 의한 재산상의 피해 및 기밀누설 등의 문제가 급증하고있는 추세이다. 이에 외부침입에 대한 근원적인 원인과 발생가능성을 미연에 방지하는 보안시스템의 개발이 무엇보다도 중요해지고 있다. 기존의 보안시스템은 인간이 직접 경계활동을 벌이는 구조 또는 장력, 광케이블을 이용한 보안망의 구조를 가지고 있다. 이들 시스템은 보안효과의 비능률성, 고가, 기계적강도의 떨어짐 등의 문제를 지니고 있다 이에 본 연구는 울타리로써의 역할만을 강조하는 기존의 펜스의 기능에 자기 판단능력을 부여함으로서 한 단계 진보된 성능의 보안시스템 개발에 그 목적을 두고 있다(중략)

  • PDF

A Study on the Criterion for Condition Decision of Distribution L.A (배전용 피뢰기 상태판정 기준제정에 관한 연구)

  • Jung, Geum-Young;Park, Dong-Hwan;Kim, Gi-Hong;Lee, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.682-684
    • /
    • 2005
  • 기기의 절연파괴를 방지하기 위해 배전선로에 설치된 피뢰기가 열화되어 선로 사고를 유발하여 이를 예방하고자 운전 중인 배전선로에서 측정 가능한 피뢰기 열화진단장치의 개발이 필요하게 되었다. 본 논문에서는 피뢰기 열화와 누설전류 측정 및 피뢰기 열화진단장치의 원리를 확인하고 이 측정한 값에 대한 판정기준을 소개하기로 한다.

  • PDF

고리1호기에 대한 냉각재상실사고해석

  • 차종희
    • Journal of the KSME
    • /
    • v.16 no.2
    • /
    • pp.6-14
    • /
    • 1976
  • 원자로의 안전성확보의 기본은 원자로의 운전에 의한여 발새하는 방사성 물질을 확실하게 관리하 여 방사서의 해로부터 공중의 건강과 안전을 보존하는 것이다. 원자로에는 로내의 방사성물질인 핵분열생성물의 누설을 방지하는 일련의 독립적 방벽들 즉 연료의 피복제, 원자로용기를 포함하 는 일차냉각재계용, 그리고 일차냉각재계통을 수용하는 격납용기들로 된 다중방호벽이 마련되어 있다. 원자로설계기준에서는 이들 방호벽이 어떠한 가상적사고가 발생하여도 그 건전성이 유지되 도록 요구하고 있디. 우리나라에서도 미국의 기준을 준용하는 원칙으로 고리 원자력발전소 등 1 호기에 대한 해석이 수행되었던 것이다. 여기서 해석판정기준 및 해석결과를 소개하고저 하는 것이다.

  • PDF

A study of Protection for electrical corrosion by stray current in DC railway system (직류전기철도시스템에서의 누설전류에 의한 전식방지에 대한 연구)

  • Lee Jae-young
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.748-753
    • /
    • 2005
  • The stray current(leakage current) in DC railway system like as Metro Subway and LRT system happens electrical corrosion on theses superstructure facilities and also underground facilities that causes the public property losses. we must study and establish on the theoretical concept and concrete phenomena for electrical corrosion, In the construction period we intend to review and find out a lot of solution to minimize theses losses. we must investigate, measure and analysis natural atmosphere of these facilities locations to present a maintenance management guide for the upcoming operation stage.

  • PDF