• 제목/요약/키워드: 냉동 창고

검색결과 73건 처리시간 0.031초

냉동냉장창고에 대한 에너지 절약에 대한 연구 (A Study on Energy saving for refrigeration warehouse)

  • 정춘병;김대균;김익환;이상집;함년근;전기영;이훈구;한경희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.270-274
    • /
    • 2005
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

냉동창고 출하작업의 신체부담 분석에 관한 연구 (An Analysis of Physical Load of the Shipping Work in Cold Storage Warehouses)

  • 장성록
    • 한국안전학회지
    • /
    • 제14권4호
    • /
    • pp.192-198
    • /
    • 1999
  • Work-related musculoskeletal disorders constitute a major source of employee disability and lost wages. Cumulative Trauma Disorders(CTD) refers to a category of physical conditions which result from chronic musculoskeletal injury. Assessment of CTD risk in industry at early stage allows for early control, a safe environment, and a healthier workforce. In this study, the physical load of the shipping work in the cold storage warehouse were especially investigated. Employees were working with almost unnatural posture in a very restricted work space. The questionnaire and biomechanical analysis were used to evaluate the physical load. Results from analyses showed that they were sufficiently exposed to CTD due to repetition and unnatural posture. Based on the analysis, ways for improving working conditions are proposed. The analysis and proposals in this paper will serve as a basic tool for designing/redesigning working environment such as improvement of tools and equipments, design of times for work/rest cycle.

  • PDF

농수축산물저장을 위한 지하암반냉동창고의 경제성분석 (An Economy Analysis on the Underground Food Storage)

  • 김준홍
    • 산업경영시스템학회지
    • /
    • 제19권38호
    • /
    • pp.189-197
    • /
    • 1996
  • It is in general reported that construction cost in an underground storage facility is less than that of the same capacity and features in an aboveground facility. Since these costs have a derivative with respect to facility size and fridging unit, the cost of construction and fridging unit are sensitive to location of storage, items to store, and rock quality of storage site. In this paper, to analyse an economic investment point for the underground food storage relative to aboveground storage, we compared these two models which have equivalent annual cost with the total cost that consists of initial facility investment cost and annual operation cost. Based on comparison of the economic investment in the underground with aboveground storage. an economic initial investment cost has been suggested for storing the agricultural and fish products.

  • PDF

이천 냉동창고 화재분석을 통한 제도개선방안 연구 (A Study on Enhancing Institutionalization on the Fire Analysis of the Warehouse at Icheon City)

  • 정태호;박상현;김희규
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.80-84
    • /
    • 2008
  • This research has been carried out in order to provide countermeasure plans, fire prevention, improving institutional plans through analyzing accidental causes and investigating the situation of damage from the fire incident of the cold storage at Icheon. By the analysis of the incident, which is organized the process; for incidence, firstly a field investigation, next the overview of related laws, finally the analysis of problems and deducting suggestions, it was possible to find out the causes of casualties. We also suggested improving plans through finding out several problems such as safety management system and safety regulations, the permit on the completion of the cold storage and the completion examination of fire facilities as institutional problems and fireproof construction and the selection of finishing materials.

  • PDF

천정 천공 유무에 따른 화재 특성 연구 (A Study on the Characteristics of Fires Depending on the Existence of Boring on the Ceiling)

  • 이동호;최백열;서문수철;유명열
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.16-20
    • /
    • 2010
  • 본 연구는 지하 냉동 창고 화재발생시 천공이 화재진압의 방법으로써 화재성상에 미치는 영향 등 천공의 효과를 검증하고 화재진압 기술에 대한 기초연구로서 천공의 위치, 천공 개방 시간, 천공 개방에 따른 근접 건축물로의 화재 전파양상을 FDS를 통하여 시뮬레이션 하여 분석하였다. 천공의 개방은 내부 화재의 요인을 빨리 소모시켜 온도 및 발열량을 빠르게 낮춘다. 이와 같이 천공의 유무에 따라 화재에 양상이 바뀌기 때문에 화재 진행 사항 및 화재 장소 가연물에 형태 등 각 화재 형태에 따라 적절한 천공의 위치 및 개방시간등이 마련되어야 할 것이다.

  • PDF

에너지 절감 기법을 적용한 냉동 냉장 창고 운영에 관한 연구 (A Study on Refrigeration warehouse operation for Energy saving technique)

  • 김대균;권중동;함년근;이상집;김익환;이승환;이훈구;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.182-184
    • /
    • 2005
  • The human beings have Increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, intelligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

냉동.냉장창고용 냉수펌프의 에너지절감 기법 (Energy saving technique of Refrigeration warehouse Cold Water Pump)

  • 정춘병;전기영;이상집;김대균;이훈구;한경희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.409-414
    • /
    • 2005
  • We are interaction refrigeration warehouse cold water pump system and photovoltaic generation system. At this time, a target pressure is able to control in spite of change of the pressure according to pump head and rate of flow of pump. Also, we carry out the vector control of BLDC moor with the maximum torque operation and a high reliability from territory of each operation speed. Therefore, in this paper, we conclude energy saving technique of refrigeration warehouse cold water pump system.

  • PDF

냉동 창고 상시 적재하중에 관한 확률론적 연구 (Probabilistic Analysis of Design Live Loads on A Refrigeration Store)

  • 김대호;정재훈;원영술;주경재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권4호
    • /
    • pp.109-120
    • /
    • 2001
  • Live load data were collected with a systematic manner from a survey of a refrigeration stores. Using the collected floor live load survey data, the basic statistics, a histogram of the uniformly distributed loads, and the equivalent uniformly distributed loads are computed for various structural members. Based on the above results, the maximum values of a combined live loads during the design life have been estimated and compared with current design live loads. The ultimate goals of this study are to develop probabilistic live load models to analyze survey data of domestic refrigeration stores, and to propose design live loads for structural types.

  • PDF

감천항 방파제 부근수역에서 충돌위험

  • 최지웅
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2023년도 춘계학술대회
    • /
    • pp.245-245
    • /
    • 2023
  • 감천항 내에는 벌크선석, 어획물 전용 냉동창고, 어획물 공동경매장 및 수리조선소등이 있다. 다양한 목적의 선석과 시설에 따라 조종불능선, 조종성능제한선, 견시불량선, 대형벌크선, 강제도선면제선박 및 어선등 이 감천항 방파제 부근수역을 이용한다. 특히 입출항하는 GT 20,000톤 - 50,000톤 크기의 벌크선박과 VHF교신이 되지 않는 어선들과 방파제 부근수역에서 조우상태가 되어 충돌사고 발생 위험이 존재한다. 따라서, 본연구는 선박 충돌사고를 예방하기 위하여 충돌위험요소를 확인하고 충돌위험요소 제거를 위한 방안을 모색하였으며, 또한 더욱 세심한 연구가 진행되기 위함을 목적으로 한다.

  • PDF

냉동 물류 창고 내 도크시스템을 통한 에너지 손실량 분석 (Analysis of Amount of Energy Loss for a Dock System in the Cold Distribution Center)

  • 양성준;김영주;허준;김태성
    • 설비공학논문집
    • /
    • 제29권8호
    • /
    • pp.419-428
    • /
    • 2017
  • In this study, energy loss due to ventilation load in the dock system was analyzed through simulation. Also, flow generated in the dock system of the warehouse was measured using manufactured measuring devices. Numerical simulation was conducted by simulating the most common picking tasks by examining the actual working environment. Incompressible and unsteady turbulent flows were assumed, and the turbulence model was the k-e standard model. Proper grid was selected through grid dependency test. Measurement was conducted using Honeywell and Vaisala sensors, and flow and temperature inside the warehouse were measured and compared with simulation results to validate simulation. When comparing amount of loss occurring in two hours and amount of loss occurring in 15 minutes, docking time of the former was eight times longer but energy loss was 3.8 times lower. Ventilation load occurring during the initial period after opening docking system accounted for a large proportion of total ventilation load. Also, comparing the load when the dock was closed and the load when the truck was parked, ventilation load was significantly higher than load due to heat conduction from the wall. Therefore, in improving the docking system, it is effective to reduce the gap by improving compatibility of the docking system and truck, rather than wall material.