Research Plan to improve Power Generation Efficiency of Photovoltaic Units using Photovoltaic Module Cooling System (태양광모듈 냉각장치를 이용한 태양광발전장치 발전효율 향상을 위한 연구방안)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.1
    • /
    • pp.199-204
    • /
    • 2020
  • In case of the silicon solar panel being used in Korea, the production specification is designed to give maximum output at the limit of -0.5 to 0.05℃, so the output of 0.45~0.55% decreases when the temperature rises by 1℃. As a result, the photovoltaic power generation is reduced according to the surface temperature rise of the photovoltaic module due to the characteristics of the solar cell. The decrease in output reduces the efficiency of photovoltaic power generation, and if the efficiency decreases, the result is that the profit of electricity sales according to the amount of photovoltaic power generation decreases. Therefore, this paper proposes a method of spraying cooling air to the lower (or surrounding) of the photovoltaic module when it is identified above the set temperature by the temperature detection sensor. In addition, the amount of power generated is increased by utilizing the lost solar energy, and by applying cooling function through cooling air, the power generation can be further increased.

Thermal-Fluid Analysis with Flow Loss Coefficient on the Inlet and Exhaust Duct of Wheel-Loader (휠로더 흡배기구의 유동손실계수를 적용한 열유동해석)

  • Jeong, Chan-Hyeok;Lee, Jae-Seok
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.97-104
    • /
    • 2017
  • In this study, we verify the accurate numerical analysis and simplify the perforated plate of inlet and exhaust duct using porous media for the cost reduction and the efficiency improvement of thermal-fluid analysis to evaluate cooling performance of wheel-loader. The flow loss coefficient of the perforated plate is defined by the experiment result. To define analytically the flow loss coefficient of the perforated plate, we calculate the pressure drop of unit-cell and compare to experiment result. Finally, we compare the heat balance test and the simplified simulation result on the inlet and exhaust duct of wheel-loader. After this study, we verify the applicability of the simplified analysis method on the inlet and exhaust duct of wheel-loader. And, foundation which can carry out effectively the evaluation and improvement for cooling performance of wheel-loader is prepared.

Feasibility Study on Ultrasonic Waveguide Sensor for Under-Sodium Viewing of Reactor Internals in Sodium-Cooled Fast Reactor (소듐냉각고속로 원자로 내부구조물의 소듐내부가시화를 위한 웨이브가이드 초음파센서의 적용 가능성 연구)

  • Joo, Young-Sang;Lim, Sa-Hoe;Park, Chang-Gyu;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.364-371
    • /
    • 2008
  • Ultrasonic waveguide sensor has been developed for under-sodium viewing of reactor internal structures of a sodium-cooled fast reactor (SFR). The structure design concept of a waveguide sensor assembly was suggested and evaluated for the application in SFR. A 10 m long ultrasonic waveguide sensor assembly has been manufactured and the experimental feasibility tests were carried out. The 10 m long distance propagation performance of zero-order antisymmetric $A_0$ Lamb wave has been verified. The feasibility of ultrasonic waveguide sensor has been demonstrated by the C-scanning resolution performance test.

Optimal Design of Graphite Sheet based Cryogenic Cooler Thermal Control System using Veritrek Software (Veritrek 소프트웨어를 활용한 그라파이트시트 기반 극저온 냉각기 열 제어 시스템 최적설계)

  • Bong-Geon Chae;Hye-In Kim;Hyun-Ung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.2
    • /
    • pp.71-78
    • /
    • 2024
  • During the initial thermal design process, determining the thermal effect of various design variables in a complex orbital thermal environment is time-consuming. To save time in the initial design phase, it is necessary to quickly derive optimal design parameters and predict the temperature. To address these challenges, Veritrek, a software specialized in optimal design using a reduced-order model (ROM), was released in 2018. In this paper, we utilized the Veritrek software to build a reduced-order model, conduct sensitivity analysis, and perform optimal design analysis for a graphite sheet-based cryogenic cooler thermal control system. The goal was to determine the optimal design values for the number of graphite sheet layers, radiator area, and thickness that would meet the allowable temperature of the cryogenic cooler.

Design, Fabrication and Evaluation of a Conduction Cooled HTS Magnet for SMES (SMES용 전도냉각형 고온초전도 자석의 설계, 제작 및 평가)

  • Bae, Joon-Han;Kim, Hae-Jong;Seong, Ki-Chul
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.185-190
    • /
    • 2011
  • This paper describes design, fabrication, and evaluation of the conduction cooled high temperature superconducting (HTS) magnet for superconducting magnetic energy storage (SMES). The HTS magnet is composed of twenty-two of double pancake coils made of 4-ply conductors that stacked two Bi-2223 multi-filamentary tapes with the reinforced brass tape. Each double pancake coil consists of two solenoid coils with an inner diameter of 500 mm, an outer diameter of 691 mm, and a height of 10 mm. The aluminum plates of 3 mm thickness were arranged between double pancake coils for the cooling of the heat due to the power dissipation in the coil. The magnet was cooled down to 5.6 K with two stage Gifford McMahon (GM) cryocoolers. The maximum temperature at the HTS magnet in discharging mode rose as the charging current increased. 1 MJ of magnetic energy was successfully stored in the HTS magnet when the charging current reached 360A without quench. In this paper, thermal and electromagnetic behaviors on the conduction cooled HTS magnet for SMES are presented and these results will be utilized in the optimal design and the stability evaluation for conduction cooled HTS magnets.

A Design of the Cooling Channel in the Bipolar Plate of PEMFC Using Experimental Design Method (실험설계법을 이용한 연료전지 분리판 냉각채널 설계)

  • Zhang, Xia;Kwon, Oh-Jung;Oh, Byeong Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.5
    • /
    • pp.545-552
    • /
    • 2015
  • The heat generation in PEMFC is proportional to the electrical power output. Therefore, when the fuel cell produced the maximum output, the maximum heat was generated. In order to maintain the performance of the fuel cell, thermal management is as important as pressure and humidity conditions of the reactive gas. In this study, considering the thermal management for the maximum output operation, the optimal cooling channel design specifications of bipolar plate are found for the highest cooling performance. In the current bipolar plate research, many studies focused on analyzing various factors individually but there is no more study on the interaction between design factors. In this study, the heat transfer was simulated by COMSOL Multiphysics with the main design factors which are designated shape, width and rib length. One of the experimental design methods, general full factorial design method, was used to analyze the main factor and interaction on average temperature and maximum temperature for the design specification of fuel cell bipolar plate. When analysis result shows that all of these three factors are highly important, it can confirm that the interaction occurs between the factors.

Operational and Thermal Characteristics of a Microchip Yb:YAG Laser (마이크로 칩 Yb:YAG 레이저의 동작 및 열적 특성)

  • Moon, Hee-Jong;Hong, Sung-Ki;Lim, Chang-Hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.2
    • /
    • pp.96-101
    • /
    • 2011
  • Operational and thermal characteristics of a thin disk Yb:YAG crystal with a thickness of 0.8 mm were studied using as a pumping source a fiber-coupled 930 nm laser diode. The heat generated in the crystal was dissipated by placing both surfaces in contact with copper plates with central hole, and the dependence of the temperature change in the illuminated spot on hole size was investigated by measuring the spectral change of the lasing peaks. The slope efficiency and optical-to-optical efficiency with respect to the LD pump power were as high as 42.2% and 34.8%, respectively. The temperature at the illuminated spot increased with diode current and with increasing hole size of the copper plate. When the hole size considerably exceeded the crystal thickness, the temperature rise deviated from the linear increase at high pump power.

A Primary Study on the Enhancement of Efficiency in the Computer Cooling System using Entrance Tube of Outer Air (외부공기 유입관을 이용한 컴퓨터 냉각시스템의 효율향상에 관한 연구)

  • Kim, S.H.;Kim, M.H.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.56-61
    • /
    • 2009
  • In recent years, since the continuing increase in the capacity in personal computer such as the optimal performance, high quality and high resolution image, the computer system's components produce large amounts of heat during operation. This study analyzes and investigates the ability and efficiency of a cooling system inside a computer by means of central processing unit (CPU) and power supply cooling fan. This research was conducted to enhancement of efficiency of the cooling system inside the computer by making a structure which produces different air pressures in an air inflow tube. Consequently, when temperatures of the CPU and room inside computer were compared with a general personal computer, temperatures of the tested CPU, the room and the heat sink were as low as $5^{\circ}C$, $2.5^{\circ}C$ and $7^{\circ}C$ respectively. In addition to, revolution per minute (RPM) was shown as low as 250 after 1 hour operation. This research explored the possibility of enhancing the effective cooling of high-performance computer systems.

  • PDF

Shape Optimization of a Rotating Two-Pass Duct with a Guide Vane in the Turning Region (회전하는 냉각유로의 곡관부에 부착된 가이드 베인의 형상 최적설계)

  • Moon, Mi-Ae;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.66-76
    • /
    • 2011
  • The heat transfer and pressure loss characteristics of a rotating two-pass channel with a guide vane in the turning region have been studied using three-dimensional Reynolds-averaged Navier-Stokes (RANS) analysis, and the shape of the guide vane has been optimized using surrogate modeling optimization technique. For the optimization, thickness, location and angle of the guide vanes have been selected as design variables. The objective function has been defined as a linear combination of the heat transfer and the friction loss related terms with a weighting factor. Latin hypercube sampling has been applied to determine the design points as design of experiments. A weighted-average surrogate model, PBA has been used as the surrogate model. The guide vane in the turning region does not influence the heat transfer in the first passage upstream of the turning region, but enhances largely the heat transfer in the turning region and the second passage. In an example of the optimization, the objective function has been increased by 13.6%.

An Experimental Study of KTP Crystal Growing by TSSG Method (TSSG 법에 의한 KTP 단결정 성장의 실험적 연구)

  • 김형천;윤경구
    • Korean Journal of Crystallography
    • /
    • v.4 no.1
    • /
    • pp.42-48
    • /
    • 1993
  • KTP(KTiOPO4) single crystals were grown by the TSSG(top seeded solution growth) method using the Ksp401s flux. A heat-pipe based growing furnace was used, and the temperature stability and the homogenity of the growing solution in the platinum crucible were within the level of It 0.5℃ and ±0.9℃, respectively. The effects of some operating variables such as operating temperature range, initial cooling rate, forced stirring, reuse of the flux were investigated. As the initial cooling rate was decreased to the degree of 0.1℃/hr and some proper stirring effect by the crystal rotation was introduced to the present experimental condition, bigger and better crystals without inclusion grew. A single crystal with the maximum sixte of 44 ×39 ×17mm3 was obtained and showed the SHG conversion efficiency of 21.39) even without the anti-refilection coating.

  • PDF