Browse > Article

Feasibility Study on Ultrasonic Waveguide Sensor for Under-Sodium Viewing of Reactor Internals in Sodium-Cooled Fast Reactor  

Joo, Young-Sang (Korea Atomic Energy Research Institute)
Lim, Sa-Hoe (Korea Atomic Energy Research Institute)
Park, Chang-Gyu (Korea Atomic Energy Research Institute)
Lee, Jae-Han (Korea Atomic Energy Research Institute)
Publication Information
Abstract
Ultrasonic waveguide sensor has been developed for under-sodium viewing of reactor internal structures of a sodium-cooled fast reactor (SFR). The structure design concept of a waveguide sensor assembly was suggested and evaluated for the application in SFR. A 10 m long ultrasonic waveguide sensor assembly has been manufactured and the experimental feasibility tests were carried out. The 10 m long distance propagation performance of zero-order antisymmetric $A_0$ Lamb wave has been verified. The feasibility of ultrasonic waveguide sensor has been demonstrated by the C-scanning resolution performance test.
Keywords
Sodium-Cooled Fast Reactor; Sodium; Liquid Metal; Under Sodium Viewing; In-Service Inspection; Waveguide Sensor; Leaky Lamb Wave;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 J. A. McKnight, et al., 'Recent advanced in the technology of under-sodium inspection in LMFBRs,' Liquid Metal Engineering and Technology, Vol. 1, pp. 423-430, ,BNES, London, England, (1984)
2 American Society of Mechanical Engineers, 'Rules for in-service inspection of nuclear power plant component,' ASME Boiler and Pressure Vessel Code, Section XI, Division 3, ASME, New York, (1992)
3 N. Lions, et al., 'Utilization and performance of sodium instrumentation during sart-up and initial operation of phenix,' Int. Conf. on Liquid Metal Technology in Energy Production, pp. 755-761, (1980)
4 R D. Watkins, et al., 'A proposed method for generating and receiving narrow beams of ultrasound in the fast reactor liquid sodium environment,' Ultrasonics, Vol. 20, No. 1, pp. 7-12, (1982)   DOI   ScienceOn
5 J. A. McKnight and P. Fenemore, 'Under-sodium ultrasonic technology for LMFBRs,' Science and Technology for Fast Reactor Safety, BNES, London, pp. 585-590, (1986)
6 D. Hahn, et al., KALIMER-600 Conceptual Design Report, KAERI/TR-3381/2007, p. 363, (2007)
7 T. Susuki, et al., 'Development of FBR visual inspection technique in sodium,' Proceedings of ICONE 3, S212-2, pp. 905-910, (1995)
8 D. Watkins, L. M. Barrett and J. A. McKnight, 'Ultrasonic waveguide for use of the sodium coolant of fast reactors,' Nucl. Energy, Vol. 27, No. 2, pp. 85-89, (1988)
9 Y. S. Joo and J. H. Lee, 'Beam steering technique of ultrasonic waveguide sensor for under-sodium inspection of sodium fast reactor', 13th International Conference on Nuclear Engineering, ICONE 13-50340, (2005)
10 G. Seed, 'In-service inspection and monitoring of CDFR,' Nucl. Energy, Vol. 25, No. 2, pp. 129-135, (1986)
11 J. P. Argous, et al., 'Immersed acoustical transducers and their potential uses in LMFBR,' Int. Conf. on Liquid Metal Technology in Energy Production, CEA-CONF 5257, (1980)
12 N. Lions, et al., 'Apparatus for ultrasonic visualization in sodium (VISUS) and acoustic detection in the phenix reactor,' ORNL-TR- 4136, (1973)
13 J. L. Rose, Ultrasonic Waves in Solid Media, Cambridge University Press, New York, (1999)
14 Y. S. Joo and J. H. Lee, 'Development of ultrasonic waveguide sensor for under-sodium viewing in liquid metal reactor,' J. of Korean Society for Nondestructive Testing, Vol. 26, No. 1, pp. 18-24, (2006)   과학기술학회마을