• Title/Summary/Keyword: 냉각법

Search Result 499, Processing Time 0.026 seconds

Optimization of Extraction of Marker Compounds from Red Ginsengs by Accelerated Solvent Extraction Using Response Surface Methodology (반응표면분석법을 사용한 가속 용매 추출에 의한 홍삼 지표성분의 추출 최적화)

  • Kim, Eun Ok;Xu, Jiu Liang;Um, Byung Hun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.8
    • /
    • pp.1162-1169
    • /
    • 2016
  • A new method based on accelerated solvent extraction (ASE) combined with response surface methodology (RSM) has been developed for optimization of the extraction of ginsenoside [Rb1, Rg1, and Rg3(20S)], total phenolics, and benzopyrene in red ginseng. The RSM method, based on a five level and two variable central composite design, was employed to obtain the optimal combination of extraction conditions. In brief, ginsenosides Rb1, Rg1, and Rg3(20S) and total phenolics with undetectable benzopyrene were optimally extracted with 50% ethanol as an extraction solvent, extraction temperature of $158^{\circ}C$, extraction time of 20 min, extraction pressure of 2,500 psi, flush volume of 60%, and one extraction cycle. The contents of ginsenosides and total phenolics in red ginseng extracted by ASE under optimum conditions were significantly higher than those extracted by sonication and reflux extraction.

A Study of Loudspeaker Specifications by the Back Cavity and a change of Electrical Load (스피커의 후면기공과 입력부하의 변화에 따른 스피커의 음향특성)

  • Yon Ju-Bong;Yi Han-Ryang
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.233-236
    • /
    • 2001
  • 일반적으로 스피커를 동작시키게 되면, 스피커 보이스 코일에 열이 발생하게 되고, 열에 의한 보이스코일의 저항의 증가가 나타나게 되는데, 기존의 연구는 저음용 스피커(Woofer) 만을 대상으로 스피커의 음향특성 변화들에 관해 수행되었다. 그러나, 현대의 스피커는 A/V시스템분야의 발전에 따라 고음재생의 충실도가 강조되고 있는 경향이므로, 고음용 스피커(Tweeter)에 대한 열 발생의 영향을 조사하였다. 본 연구에서는 고음용 스피커의 입력전력에 따른 특성 변화를 조사하고, 입력전력의 증가로 인한 보이스코일(voice coil)의 저항 증가에 따른 고음용 스피커의 특성변화에 관해 실험하였다. 그리고, 스피커의 진동에 의한 펌프(pump) 역할을 이용하는 냉각용 구멍을 뚫어 스피커의 특성변화를 검토하였다. 실험대상으로는 직경 25mm의 돔(Dome)형 진동판을 가진 고음용 스피커와 이 스피커의 후면 중심부에 구멍을 뚫어 열 방출구가 형성된 3종의 시료를 대상으로 특성변화를 비교$\cdot$측정하였다. 여기에서, 사용된 시료는 국내 Y사의 판매용 고음용 스피커로 제품의 원 상태인, 구멍이 없는 것을 기준시료로 하고, 이와 동일한 제품들의 후면에 각각 직경 5mm, 10mm, 15mm의 구멍을 가공하여 비교시료로 하였다. 기준 및 비교시료의 스피커 특성을, 한국산업규격 KS C 6027의 측정법에 따라, 입력 1W 상태에서 기준시료의 사양을 측정하였고[1], 입력을 0.5W, 1W, 2W, 4W, 8W, 16W로 가하여, 시료별 입력증가에 따른 스피커의 주파수 응답특성, 임피던스(Impedance), 조화 왜(Harmonic Distortion)의 변화율 측정을 통해 스피커의 특성변화 정도를 검토하였다. 향후, 본 연구의 결과는 고음용 스피커의 특성 열화에 대한 예측 및 개선 방안을 제시하는 기본 자료로 활용이 가능할 것으로 사료된다.용하여 현금흐름예측을 할 수 있는 Model을 제시하였다. 특히 건설공사의 현금흐름 예측의 중요한 요소인 Cash-Out에 대하여, 공사비 구성요소인 자재, 노무, 중기, 외주, 경비등 각 Resource의 보할(Weights)을 실 공사원가에 따른 보할의 변화와 Resource들의 Time Lag를 적용 기존 연구자의 Model과 다른 Model을 제시하였다. 또한 기존 연구자들의 Model과 비교하여 편리성, 정확도 및 신뢰성이 높은 Model임도 증명하였다.세대까지도 발현수준이 유지될 것으로 판단된다. 이러한 연구결과는 계통으로 확립된 형질전환 동물에 부여된 새로운 유전형질은 지속적으로 후대로 유전될 수 있음을 제시한다.잖⨀瘀Ā퀇Āゑ잖⨀Ā퀇Ԁ￿™잖⨀䌀Ā퀇ĀꄏĀꀏꄏĀꀏ₱?⨀Ā Ԁ￿䂱?⨀ऀĀ耀Ā삱?⨀؀Ā Ā?⨀ጀĀ耀Ā?돀ꢘ?⨀硩?⨀ႎ?⨀?⨀넆돐쁖잖⨀쁖잖⨀/ࠐ?⨀焆덐瀆倆Āⶇ퍟ⶇ퍟ĀĀĀĀ磀鲕좗?⨀肤?⨀⁅Ⴅ?⨀쀃잖⨀䣙熸ጁ↏?⨀

  • PDF

Presence of Bacteria and Fungi in Inner Compartment of Personal Computers(PCs) (개인용 컴퓨터 내부에서 발견되는 세균과 곰팡이)

  • Kwon, Kil-Koang;Yoon, Seok-Min;Choi, Chang-Ho;Jeong, Bong-Geun;Lee, Ki-Won;Yi, Dong-Heui;Kim, Hyung-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.728-733
    • /
    • 2007
  • Presence and distribution of bacteria and fungi in inner compartment of PCs(Personal Computers) were investigated. Samples for the analysis were collected from inside of PCs which had been used in various facilities including public computer facilities, laboratories and computer training rooms of a university. Total number of PC examined in this study was 51 each. When the total CFU(colony forming unit) of the inner compartment of the PCs was measured, the bacterial count was found to be dependent on the operation time(total running time) of PCs. When the distribution of bacteria in the inner compartment of PCs was estimated, CPU(Central Processing Unit) cooling fan area showed the highest bacterial concentration(average 605 $CFU/cm^2$). In the case of the fungi, various opportunistic pathogens including Aspergillus sp. and Penicillium sp. were isolated and identified in the inner compartment of PCs. And the average of bacterial number in the dust collected from the PCs was 212 CFU/mg. These results indicated that handling of PC might have a risk of infection by the microorganism.

Determination of Rare Earth Elements by Inductively Coupled Plasma Mass Spectrometry with Introduction of Organic Phase Using Ultrasonic Nebulizer (초음파 분무기를 이용한 유기상의 주입에 의한 희토류 원소의 유도결합 플라스마 질량분석법적 정량)

  • Lee, Sang Hak;Son, Bum Mok
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • Analytical method to determine rare earth elements which were extracted to organic phase by inductively coupled plasma mass spectrometry(ICP-MS) was investigated. Organic phase which had extracted rare earth elements was directly aspirated into ICP-MS by ultrasonic nebulizer(USN) in order to reduce solvent load to the plasma. Then, the count rate increased when MIBK(methyl isobutyl ketone) was added to EtOH(ethanol) but decreased when 0.03 M HEH(2-ethylhexyl-2-ethylhexyl phosphonic acid, $P_{507}$, PC88A) was added to solvent which mixed MIBK with EtOH. The optimal temperatures of desolvation system were -10 $^{\circ}C$ for the condenser and 150 $^{\circ}C$ for the heating tube. The optimal nebulizer flow rate which gave maximum count rate and minimum reflect power was 0.7 L/min. The optimal pH and extraction time were 4.3 and 10 min for MIBK-0.03 M HEH system. Detection limits which were obtained through calibration curves at the range of 0.2 ${\sim}$ 20 ng/mL were 0.02 ${\sim}$ 0.05 ng/mL under the optimal experimental conditions.

Analytical Evaluation of Residual Stresses in Dissimilar Metal Weld for Cast Stainless Steel Pipe and Low-Alloy Steel Component Nozzle (스테인리스주강 배관과 저합금강 기기노즐 이종금속용접부 잔류응력의 해석적 평가)

  • Park, June-Soo;Song, Min-Seop;Kim, Jong-Soo;Kim, In-Yong;Yang, Jun-Seog
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.100-100
    • /
    • 2009
  • This paper is concerned with numerical analyses of residual stresses in welds and material's susceptibility to stress corrosion cracking (SCC) for the primary piping system in nuclear power plants: Both the dissimilar metal weld (DMW) for stainless steel to low alloy steel joints and the similar metal weld (SMW) for forged stainless steel to cast stainless steel joints are considered. Thermal elasto-plastic analyses using the finite element method (FEM) are performed to predict residual stresses generated in fabrication welding and its related processes for both the DMW and SMW, including effects of quenching for cast stainless steel piping, machining of the DMW root, and grinding of the SMW root. As a result, the effect of quenching should be included in the evaluation of residual stresses in the SMW for the cast stainless steel piping. It is deemed that residual stresses in both the DMW and SMW would not affect the SCC susceptibility of the welds providing that the welding processes are completed without any weld repair on the inside wall of the joint. However, the grinding process if performed on the safe-end to piping weld, would produce a high level of residual stresses in the inner surface region and thus a stress improvement process (e.g. buffing) should be considered to reduce susceptibilities to SCC.

  • PDF

Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals (소동물 발광영상 측정을 위한 광학분자영상기기의 개발)

  • Lee, Byeong-Il;Kim, Hyeon-Sik;Jeong, Hye-Jin;Lee, Hyung-Jae;Moon, Seung-Min;Kwon, Seung-Young;Choi, Eun-Seo;Jeong, Shin-Young;Bom, Hee-Seung;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.344-351
    • /
    • 2009
  • Purpose: Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. Materials and Methods: In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. Results: We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. Conclusion: We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future.

그래핀-탄소나노튜브 복합체로 제작한 유연성 투명 전도막의 반복 변형에 대한 내구성 향상

  • Lee, Byeong-Ju;Jeong, Gu-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.202-202
    • /
    • 2012
  • 유연성 투명 전도막은 현대 전자산업의 발전에 있어 필수적인 부품소재로서, 가시광선의 투과율이 80% 이상이고 면저항이 $100{\Omega}/sq.$ 전후이며 휘거나 접히고 나아가 두루마리의 형태로도 응용이 가능한 소재를 일컫는다. 이러한 유연성 투명 전도막은 차세대 정보디스플레이 산업 및 유비쿼터스 사회의 중심이 되는 유연성 디스플레이, 터치패널, 발광다이오드, 태양전지 등 매우 다양한 분야에 응용이 기대된다. 이러한 이유로 고 신뢰성 유연성 투명 전도막 개발기술은 차세대 산업에 있어서의 핵심기술로 인식되고 있다. 현재로서는 인듐 주석 산화물(indium tin oxide; ITO) 및 전도성 유기고분자를 사용하여 투명 전도막을 제조하고 있으나, ITO 박막의 경우 인듐 자원의 고갈로 인한 가격상승 및 기판과의 낮은 접착력, 열팽창계수의 차이로 인한 공정상의 문제, 산화물 특유의 취성으로 인한 유연소자로서의 내구성 저하 등의 문제가 제기되고 있다. 전도성 유기고분자의 경우는 낮은 전기전도도와 기계적강도, 유기용매 처리 등의 문제점이 지적되고 있다. 따라서 높은 전기전도도와 투광도 뿐만 아니라 유연성을 지니는 재료의 개발이 요구되고 있는 실정이다. 최근 이러한 재료로서 그래핀(graphene)과 탄소나노튜브(carbon nanotube; CNT)를 중심으로 하는 탄소나노재료가 주목받고 있으며 많은 연구가 활발히 진행되고 있다. 본 연구에서는 열화학기상증착법(thermal vapor deposition; TCVD)으로 합성된 그래핀 및 CNT를 이용하여 탄소나노재료 복합체 기반의 유연성 투명 전도막을 제작하고 그 특성을 평가하였다. 그래핀과 CNT합성을 위한 기판으로는 각각 300 nm 두께의 니켈과 1 nm 철이 증착된 실리콘 웨이퍼를 이용하였으며, 원료가스로는 메탄(CH4)과 아세틸렌(C2H2)등의 탄화수소가스를 이용하였다. 그래핀의 경우 원료가스의 유량, 합성온도, 냉각속도를 변경하여 대면적으로 두께균일도가 높은 그래핀을 합성하였으며, CNT의 경우 합성시간을 변수로 길이 제어합성을 도모하였다. 합성된 그래핀은 식각공정을, CNT는 스프레이 증착공정을 통해 고분자 기판(polyethylene terephthalate; PET) 위에 순차적으로 전사 및 증착하여 탄소나노재료 복합체 기반의 유연성 투명 전도막을 제작하였다. 제작된 탄소나노재료 복합체 기반의 유연성 투명 전도막은 물리적 과부하를 받았을 때 발생할 수 있는 유연성 투명 전도막의 구조적결함에 기인하는 전도성 저하를 보상하는 특징이 있어, 그래핀과 탄소나노튜브 각각으로 제조된 유연성 투명 전도막보다 물리적인 하중이 반복적으로 인가되었을 때 내구성이 향상되는 효과가 있다. 40% 스트레인을 반복적으로 인가하였을 때 그래핀 투명 전도막은 20 사이클 이후에 면저항이 $1-2{\Omega}/sq.$에서 $15{\Omega}/sq.$ 이상으로 급증한 반면 그래핀-CNT 복합체 투명 전도막은 30사이클까지 $1-2{\Omega}/sq.$ 정도의 면저항을 유지하였다.

  • PDF

A study on the development of phthalate plasticizers CRM in ABS resin (ABS 중 phthalates 가소제 CRM 개발에 대한 연구)

  • Jung, Jung-Sul;Park, Jung-Woo;Yoo, Seok;Kweon, Seong-Il;Hong, Sung-Taeg;Sun, Yle-Shik;Park, Cheon-Min;Choi, Chang-Hyoo
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.273-283
    • /
    • 2012
  • Phthalate plasticizers are regulated by RoHS, REACH and CPSC as hazardous substances. Responding to these international environmental restrictions, we developed ABS certified reference material (CRM) for determination of phthalate plasticizers such as DMP, DEP, DBP, BBP, DEHP and DnOP. The candidate material has been made with ABS resin widely used in electric and electronic products and 6 kinds of phthalate plasticizers. The making of the material involved a series of processes like extruding, cooling, pelletizing, and drying using twin screw extruder. Then it has been certified according to ISO Guide 35. Using isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS), homogeneity, short-term stability, and long-term stability were evaluated. The certified values were determined by using primary reference material (PRM) of KRISS for traceability. From now on, we will provide ABS CRM to national and international companies and research institutes after certification as certified reference material and registering on COMAR (code of reference material).

Rheological characterization of thermoplasticized injectable gutta percha and resilon (열연화주입형 gutta percha와 resilon의 유변학적 특성)

  • Chang, Ju-Hea;Baek, Seung-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.377-384
    • /
    • 2011
  • Objectives: The purpose of this study was to observe the change in the viscoelastic properties of thermoplasticized injectable root canal filling materials as a function of temperature and to compare the handling characteristics of these materials. Materials and Methods: Three commercial gutta perchas and Resilon (Pentron Clinical Technologies) in a pellet form were heated in the Obtura-II system (Obtura Spartan) at $140^{\circ}C$ and $200^{\circ}C$, and the extrusion temperature of the thermoplasticized materials was measured. The viscoelastic properties of the materials as a function of temperature were evaluated using a rheometer. The elastic modulus G', viscous modulus G", loss tangent tan${\delta}$, and complex viscosity ${\eta}^*$ were determined. The phase transition temperature was determined by both the rheometer and a differential scanning calorimeter (DSC). The consistency of the materials was compared under compacting pressure at $60^{\circ}C$ and $40^{\circ}C$ by a squeeze test. Results: The three gutta perchas had dissimilar profiles in viscoelastic properties with varying temperature. The phase transition of softened materials into solidification occurred at $40^{\circ}C$ to $50^{\circ}C$, and the onset temperatures obtained by a rheometer and a DSC were similar to each other. The onset temperature of phase transition and the consistency upon compaction pressure were different among the materials (p < 0.05). Resilon had a rheologically similar pattern to the gutta perchas, and was featured between high and low-flow gutta perchas. Conclusions: The rheological characteristics of the thermoplasticized root canal filling materials changed under a cooling process. The dissimilar viscoelastic properties among the materials require different handling characteristics during an injecting and compacting procedure.

Effects of Illite Supplementation on the Meat Quality of Finishing Pigs (황토성분(Illite) 첨가 급여가 비육돈의 육질에 미치는 영향)

  • 김천제;이의수;송민석;조진국
    • Food Science of Animal Resources
    • /
    • v.20 no.2
    • /
    • pp.152-158
    • /
    • 2000
  • This study was conducted to investigate the influence of feeding illite(yellow soil component) on meat quality of pork. 40 pigs were fed with commercial formulated feed (control group) and 1% illite added feed(treatment group). Pigs grown up to 100~110kg of weight were slaughtered in commercial abattoir. After chilling for 24hours, samples were collected from M. longissimus dorsi muscle, and stored at $4\pm$$1^{\circ}C$ for analyses. The physico-chemical properties was determined during storage days as follows. Ultimate pH was not significantly different between control and treatment(pH 5.58 and 5.60, respectively). Water-holding capacity measured using filter paper press method of the treatment group was slightly higher than that of the control group. Cooking loss of treatment group were significantly lower than that of the control group at 1 and 7 days(p〈0.05). Shear force between control and treatment group was not different. L*- and a*-value were not significantly different between the two groups(p〉0.05), but b*-value of treatment group was lower than that of the control group(p〈0.05). The drip loss of all samples was increased with storage days, and that of the treatment group was significantly lower than that of the control at 1 and 3 day storage. Meat color measured using NPPC pork quality standards was not significantly different between the two groups(p〉0.05), but marbling content of the treatment group was significantly higher than that of the control group(p〈0.05). Sensory characteristics of, flavor taste and tenderness did not show significant differences(p〉0.05), but juiciness of the treatment group showed higher value than that of the control group(p〈0.05)

  • PDF