• Title/Summary/Keyword: 내화학성능

Search Result 84, Processing Time 0.027 seconds

Spalling Properties of 60, 80MPa High Strength Concrete with Fiber (복합섬유(PP, NY)를 혼입한 60, 80MPa 3성분계 고강도콘크리트의 내화특성)

  • Kim, Seong-Deok;Kim, Sang-Yun;Bae, Ki-Sun;Park, Su-Hee;Lee, Bum-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.3-9
    • /
    • 2010
  • Fire resistance and material properties of high-strength concrete (W/B 21.5%, 28.5%) with OPC, BS and FA were tested in this study. Main factors of the test consisted of fiber mixing ratio and W/B. Two types of fiber (NY, PP) mixed with the same weight were used for the test. The fiber mixing ratios were 0%, 0.05%, 0.1%, and 0.2% of the concrete weight. After performing the test, Under the W/B level of 21.5% and 28.5%, the spalling was effectively resisted by using the high strength concrete with fiber mixing ratios of 0.05%~0.1%. Compressive strength, flowability and air content are similar those of the fiberless high-strength concrete with the same W/B.

Field Application of 80MPa High Strength Fire Resistant Concrete using Ternary Blended Cement (설계강도 80MPa 3성분계 고강도내화콘크리트의 현장적용 및 성과분석)

  • Kim, Seong-Deok;Kim, Sang-Yun;Bae, Ki-Sun;Park, Su-Hee;Lee, Bum-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.113-119
    • /
    • 2010
  • Fire resistance and field tests for high-strength concrete(HSC) of 80MPa were carried out to evaluate whether or not it shows the same material properties even in the field condition of being mass-produced and supplied. As a result, it was found that fire resistant HSCs containing composite fiber(NY, PP) of 0.075% have great resistance to fire and spalling. In the field test, before the pumping air contents, slump flow, U-box, L-flow, compressive strength, gap of hydration temperature of interior and exterior of specimen and placing ratio per hour satisfied the required properties of HSC. However, after the pumping of HSC, as slump flow and L-flow were slightly less than required criterion, they need to be improved. In terms of hydration temperature of HSC, it was found to satisfy the related criterion. Packing ability as well as placing ratio per hour of HSC, which was about $44m^3$, show outstanding results. If slump flow of developed ternary HSC is improved after the pumping it can be useful for the construction of high-rise buildings.

Improvement of Durability in Concrete Structures Using CRM (내화학성 적층보강공법(CRM)을 활용한 콘크리트 구조물의 내구성능 향상)

  • Kim, Chun-Ho;Kim, Sang-Doh;Kim, Nam-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.145-152
    • /
    • 2013
  • As a typical construction material, concrete has been used in building all kinds of structures since the late $19^{th}$ century. Although it was recognized to secure durability as long as the regulations on design and construction have been reasonably complied, the trends of life-shortening and deterioration have frequently occurred due to all kinds of the external effects that have been experienced during the procedures of using the structures. To make matters even worse, deterioration of the concrete structures according to deterioration can not be controlled any more. Finally, the reality is that repair and maintenance are necessary in the maintenance aspect of the concrete structure. In this study, CRM(Chemical Resistance of Laminating Reinforcement Method), which had been developed to reinforce the surface of concrete and specially improve chemical resistance performance, has been applied to enhance the existing repairing and maintenance method. Therefore, the result has been drawn with comparison and analysis of the specimens applied with the general repairing and maintenance method and CRM through a variety of durability test in this study. With the result of the test, durability of the specimen applied with CRM has been more improved than the existing repairing and maintenance method, which is judged as because of the laminating effect due to reinforcement of epoxy impregnated of alkali-resistance fiber and double layered fiber reinforced seat.

An Experimental Study on Corrosion Resistance of Epoxy Coated Reinforcements (에폭시 도포철근의 내 부식성능에 관한 실험적 연구)

  • 오병환;엄주용;권지훈
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.4
    • /
    • pp.161-170
    • /
    • 1992
  • 근래 들어 철근 콘크리트에 있어서의 철근부식이 관심의 대상이 되고 있는데 그이유는 이 현상이 실제 구조물에서 광범위하게 발생함이 확인되었고 이로 인한 보수비용이 급증하였기 때문이다. 철근의 부식이 처음 거론된 것은 해양구조물과 내화학성 구조물에서였고 최근 들어서는 교량상판, 주차공간등 염기에 노출되어 철근 부식이 우려되는 각 종의 구조물에 광범위하게 그 대책이 연구되기에 이르렀다. 이와같은 철근부식이 제어방법으로는 첫째로 콘크리트의 수밀화를 들 수 있고 다음으로 콘크리트의 표면을 처리하거나 피복두께를 늘이는 방법이 있다. 마지막으로 철근자체에 방청성능을 직접 부여하여 방법에 속하는 에폭시 도포 철근의 기본적인 방청성능을 고찰하기 위해 수행되었다. 연구결과 에폭시 도포철근의 방청성능은 매우 우수함을 발견하였고 앞으로 활용이 기대되고 있다.

Efficiency Test for Surface Protecting Agents for the Chemical Resistance of Concrete Structures Using Sulfur Polymers (Sulfur Polymer를 사용한 콘크리트 구조물용 내화학성 표면보호재의 성능 평가)

  • Lee, Byung-Jae;Lee, Eue-Sung;Chung, Woo-Jung;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2014
  • Structures requiring chemical resistance are usually coated with surface protecting agents, but the cost for maintenance and re-construction is incurred due to the low durability. Therefore, in this study, sulfur was polymerized and the performance was examined so that it could be used as the concrete surface protecting agents for structures requiring chemical resistance. The evaluation results indicated that for the spray of the sulfur polymer surface coating agents, the application of the gravity type was appropriate; and for the number of coating times, about 3 cycle spray gave the best results. For the surface condition of the concrete to be coated with the surface protecting agents, outstanding quality was obtained above room temperature ($20{\sim}30^{\circ}C$), and the bond strength increased as the temperature increased. The evaluation results of the strength characteristics depending on the filler content of the surface protecting agents indicated that about 20~40% filler mixing contributed to the strength improvement as it reduced the shrinkage of the sulfur polymer. Also, the mixing of silica showed larger increase in the bond strength than the mixing of fly ash, and the most outstanding bond strength characteristics could be obtained by the mixing of both silica and fly ash. In the case of the chemical resistance, the strength reduction was minimized and outstanding chemical resistance was obtained when the fly ash and silica were substituted by 20%, respectively. The performance evaluation of the chloride ion penetration indicated that for the specimens coated with the sulfur polymer surface protecting agents, the chloride ion penetration resistance increased by 29~48% compared to the specimen without the coating of the surface protecting agent. The examination of the coating condition of the surface protecting agents, compressive strength, bond strength, chemical resistance, and salt damage resistance indicated that in the range of this study, the optimal level was when the silica and fly ash were substituted by 20%, respectively, as the filler for the sulfur polymer.

Durability and Bioassay of a Sulfur Polymer Surface Protecting Agent for Concrete Structures (콘크리트 구조물용 유황폴리머 표면보호재의 내구성능 및 생물독성)

  • Seok, Byoung-Yoon;Lee, Byung-Jae;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.29-36
    • /
    • 2015
  • In this study, to examine the use of sulfur polymer as a coating agent for concrete, durability and hazard evaluations were performed. The result of the evaluation indicated that the chemical resistance of the coating agent for concrete was outstanding against acidic, base, and alkaline solutions. The evaluation of the bond strength after an accelerated weathering test depending on the mixing condition indicated that the most outstanding strength characteristic was obtained when silica powder and fly ash were mixed at the same time. The bond strength exceeded 1 MPa in every mixing condition even after the repeated hot and cold treatment of the coating agent specimen for concrete, and the SFS mix proportion showed the highest bond strength. The examination of the accelerated carbonation and chloride ion penetration resistance of the concrete coated with the coating agent indicated that the specimen coated with the coating agent using silica powder as a filler showed the most outstanding durability. When a fish toxicity test was performed to examine the hazard of the use of the functional polymer as a coating agent for concrete, the functional polymer was found to have no effect on the organisms. When the chemical resistance, freezing and thawing resistance, carbonation, and chloride ion penetration resistance of the coating agent were considered, substituting silica powder and fly ash as the fillers of the functional polymer by 20%, respectively, was the optimal level in the range of this study.

Deterioration Diagnosis of Surface and Coating Layer for Maintenance Managements of the Membrane Structure (막구조 건축물의 유지관리를 위한 표면 및 코팅층의 열화 진단)

  • Kang, Joo-Won;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.97-104
    • /
    • 2011
  • This paper contains of descriptions of deterioration diagnosis of the surface and a coating layer for maintenance managements of large spatial structures with membrane structure. Membrane is a roofing material of the structures that its performance of durability including its performance of chemical resistance and corrosive resistance is considered to be highly important. In general, the items of diagnosis for maintenance managements such as membrane extensively include the diagnosis of deterioration of the membrane surface, of a coating layer of membrane, the diagnosis of deterioration between a coating layer and fiber, of overall surface of membrane, of the class of ropes, of reinforced belts, and of the cover of rubber. The object of this study that needs maintenance managements of the membrane with PVC and FIFE which are commonly used and shows the diagnosis results of deterioration of the surface and a coating layer.

Structural Performance and Fire Resistance Capacity of Inorganic Polymer Composites for Carbon Sheets Exposed to High Temperature (탄소섬유쉬트 보강 콘크리트용 무기계 폴리머 접착제의 내화 및 구조성능)

  • Chung, Lan;Park, Hyun-Soo
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.5
    • /
    • pp.109-115
    • /
    • 1998
  • 철근콘크리트 구조물이 과소설계되어 있거나 과다 하중이 작용하게 되면 그 구조물의 구조성능을 파악하여 보수.보강을 시행하게 된다. 최근에 가장 맣이 사용되는 보수.보강 재료로는 특히 휨내력을 보강하는데 탄소섬유를 들 수 있다. 탄소섬유쉬트는 내열성과 내호염성에 있어서 회재가 발생할 경우 보강재료로서 충분한 성능을 가지고 있다. 그러나 이를 접착시키는데 사용되는 에폭시는 유기계 물질로서 화재시 유독가스가 발생하고 내열성능도 30$0^{\circ}C$정도에도 지탱하기 어려워 화재 발생이 가능한 구조물에 사용하기 어렵다. 이 연구에서는 무기계 폴리머 복합재료로 접착된 탄소섬유를 고온(약 800~100$0^{\circ}C$, 1시간)으로 가열한 후 가열된 섬유판의 인장, 휨 전단내력을 검토하여 내열성능을 파악하고 이 섬유쉬트로 보강한 철근콘크리트 부재의 휨 성능을 실험적으로 규명하여 화재의 위험이 있는 구조물에 구조적인 보강재료로 사용이 가능한가를 검토하였다. 연구 결과, 개발된 무기계 폴리머 복합체는 인장강도, 휨강도 및 접착강도가 유기계 접착제와 유사하게 나타났고 800~100$0^{\circ}C$ 정도로 1시간 가열한 이후에도 상온 시험체 휨내력과 전단내력의 63%, 33% 정도를 유지하여 화재의 위험이 있는 부위에도 사용이 가능한 것으로 판단되었다.

Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling (분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상)

  • Park, Joo-Saeng;Kim, Se-Jong;Lee, Sang-Joon
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.4
    • /
    • pp.426-432
    • /
    • 2013
  • Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

  • PDF

Mock-Up Test for the Concrete Filled Rectangular Steel Tube Columns of 22 m height with Flowable Concrete (고유동 콘크리트를 사용한 22 m 콘크리트 충전 각형강관기둥의 시공성능실험)

  • 안종문;신성우;전상우;김진호
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.88-95
    • /
    • 2002
  • 최근 국내에 60층을 초과하는 초고층 구조물들이 많이 건설되고 있으며, 콘크리트 품질의 향상 특히 콘크리트의 고강도화에 힘입어 이를 이용한 철근 콘크리트 고층 구조물들이 증가하고 있다. 이에 따라 이들 초고층, 초대형 구조물을 지지할 수 있는 고축력, 고연성의 기둥에 대한 설계 및 시공이 요구되고 있으며, 이에 가장 적합한 구조요소라 할 수 있는 콘크리트 충전 강관기둥(Concrete Filled Steel Tube Columns : CFT Columns)의 설계 및 시공에 관심이 높아지고 있다. 이러한 콘크리트 충전 강관기둥은 콘크리트가 강관에 의해 둘러싸여지기 때문에 축하중 저항 능력이 증가되는 장점과 동일한 단면으로 H형강을 사용한 순수 철골조 H형강 기둥의 강축(strong axis)과 약축(weak axis) 문제해결과 동시에 강성 (stiffness)을 증가시킬 수 있으며, 내화 성능이 향상되고 거푸집 대체 재료로 사용되는 등 여러 가지 장점을 지니고 있다. 한편 충전 강관기둥에 작용하는 축하중은 대부분 콘크리트가 부담하게 되는데 이러한 충전강관 기둥의 장점을 극대화하기 위해서는 보통강도 콘크리트보다는 압축강도 및 탄성계수가 큰 고강도 콘크리트의 사용은 불가피하게 된다.(중략)