• Title/Summary/Keyword: 내화실험

Search Result 386, Processing Time 0.021 seconds

An Experimental Study on the Application of Fireproof Panel in Tunnel Duct Slab (터널 풍도슬라브에 사용된 내화패널의 적용성에 관한 실험연구)

  • Woo Jin Choi
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.262-269
    • /
    • 2023
  • Purpose: In this study,fire-resistance test were executed to evaluate the effectiveness of the fireproof panel attached to the PSC slab in tunnel. Method: For the fire resistance test, the RWS curve was applied and the furnace of the KICT was used. Result: As a result of the experiment, the maximum temperature measured on the concrete surface of the PSC slab with the fireproof panel was 321.8℃, which was lower than the damage limit temperature of 380℃ for concrete. Also, at the t=25mm, the maximum temperature was 35.2℃, which was lower than the damage temperature of steel, 250℃. The use of precast fire resistance panel(t=30mm) improves fire resistance of PSC structures. Conclusion: As a result of the test, a reinforcement method for attached a fireproof panel in case of fire in a tunnel or an underground roadway is provided to protect a structure from fire. In the future, it is necessary to perform the static performance test of the slab to which the fireproof panel is attached, and to confirm the adhesion performance of the fireproof panel by performing the pull-off test and the fatigue test.

장기자연폭로에 따른 내화뿜칠재의 내화성능에 관한 실험적 검토

  • Kim, Dae-Hoe;Choe, Dong-Ho;Lee, Se-Hyeon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.141-142
    • /
    • 2013
  • 철골건축물은 화재에 취약한 구조로써 내화성능 확보를 위하여 내화피복이 필수적이다. 국내에서 가장 많이 사용되고 있는 철골내화피복재는 내화뿜칠재로 폭 넓게 사용되고 있으나, 기존 제도에서 인정 당시의 내화성능은 확인이 가능하나 시간경과에 따른 내구성저하와 이에 따른 내화성능 저하가 예상된다. 이에 본 연구에서는 실내조건에서 장시간 자연폭로실험을 실시함으로써 내화뿜칠피복재의 시간경과에 따른 내화성능 저하현상을 확인하였다.

  • PDF

Study on the Fire Resistance Performance of the TSC Beam (TSC 합성보의 내화성능에 관한 연구)

  • Kim, Sung Bae;Choi, Seng Kwan;Lee, Chang Nam;Kim, Sang Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.1
    • /
    • pp.113-122
    • /
    • 2006
  • The purpose of this paper is to evaluate the fire resistance of the TSC beam, a composite beam composed of a concrete beam enclosed by steel plates. Since a discrepancy was observed between the structural mechanisms of TSC and typical composite beams, the fire performances of the two beams are likewise believed to be partially dissimilar. In this experiment, small and medium-sized TSC beams were tested under given conditions in the laboratory, with/without one of the most widely used spray-on fire protections in Korea. Furthermore, based on the steel and concrete properties under elevated temperatures that were obtained from Eurocode, temperature development across the section was suggested, analyses. To determine the capacity of a modified plastic section, th e fire performance of the model was also examined.

An Experimental Study on The Fire Resistance Performance of Steel Framed motar Beam with Loading Condition (철골철망 모르타르 보의 재하하중에 따른 내화성능변화에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Cho, Bum-Yean;Yeo, In-Hwan;Min, Byung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.103-106
    • /
    • 2011
  • 국토해양부령 제320호인 건축물의 피난 방화구조 등의 기준에 관한 규칙 제 3조에서는 내화구조에 관한 세부기준을 정하고 있다. 이러한 법정내화구조 중에서 철골철망 모르타르조의 피복두께에 따른 내화성능 변화를 분석하기 위하여, 본 연구에서는 고온 재하하중조건에서 내화실험을 수행하였다. 철골조의 피복두께를 50 mm ${\cdot}$ 60 mm ${\cdot}$ 70 mm로 변화하여 내화실험을 수행하였으며, 재하하중비를 변화시킴으로 동일 피복두께에서의 내화성능 변화를 분석하고자 하였다. 실험결과 단면소성모멘트 대비 하중비 0.4 조건에서의 철골철망 모르타르조의 내화성능은 180분이 나왔으며, 피난 방화구조 등의 기준의 별표 1에서 정하고 있는 내화구조의 성능기준 중 최대 내화성능시간인 3시간을 확보하는 것으로 나타났다.

  • PDF

A Study on Fire Resistance Using The Scale Experiments (축소실험을 통한 내화시험에 관한 연구)

  • Moon, Sung-Woong;Jeon, Jun-Pyo;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.176-179
    • /
    • 2011
  • 국내에서는 방화구획을 설정하여 화재 확산 방지 및 재실자의 대피 시간을 확보하고 있다. 방화구획에 설치되는 방화문은 방화문의 내화시험방법(KS F 2268-1)에 따라 시험을 거쳐 성적서를 발급 받은 제품에 대해 설치하도록 의무화 하고 있다. 그러나 본 시험방법은 시험체 제작, 설치 및 의뢰시험비용 등 상당한 비용이 소요될 뿐 아니라 제작, 설치, 시험에 소요되는 시간 또한 길다. 축소실험장치는 목재방화문 개발 중 재료의 내화성능을 평가할 장치로 개발되었으며, 표준시간-가열 온도곡선을 상회하는 가열실험을 통해 재료의 내화성능 결과를 얻을 수 있다. 본 실험에서는 난연 또는 불연성능이 뛰어난 재료를 대상으로 실험하였으며, 그 결과 난연목재는 5분, 마그네슘보드와 내화 직물원단은 60분의 내화성능을 갖춘 것으로 확인되었다. 이 결과를 토대로 방화문의 내화시험방법과 상관성을 도출하여 목재방화문 개발의 지표로 활용 가능하게 되었다.

  • PDF

Experimental Study on the Fire Proofing Characteristic of Fire Resistance Panel that it attaches to PSC Airpit-Slab (PSC 풍도슬래브에 부착된 내화패널의 내화특성에 관한 실험연구)

  • Lee, Doo Sung;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.465-473
    • /
    • 2013
  • In this Study, the performance of precast PSC slabs with fire resistance panel for fire resistance of the tunnel system was evaluated by experimentally. The fire test was performed in fire resistance (electric) furnace according to RABT(Richtlinien fur die Ausstatung und den Betrieb von stra${\beta}$entunneln) time heating temperature curve. The test results showed that the measured temperatures at the t=0 mm depth of PSC slab with precast fire resistance panel during a fire was maximum temperature $367^{\circ}C$, lower than $380^{\circ}C$ (ITA 2004), when damage occurs. Also, at the t=25 mm, the maximum temperature was $239^{\circ}C$, which was lower than the damage temperature of rebar, $250^{\circ}C$. From the results, the use of precast fire resistance panel (t=25 mm) improves fire resistance of PSC structures.

Technology Development of Domestic Chrome Castable Refractory Application for Slagging Type High Temperature/Pressure Gasifier (슬래깅 방식 고온/고압 가스화기의 국산 크롬 내화재 적용 기술 개발)

  • Chung, Seok-Woo;Jung, Woo-Hyun;Seo, Seok-Jung;Hwang, Sang-Yeon;Choi, Young-Chan;Jung, Hun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.867-870
    • /
    • 2009
  • 일반적으로 내화재의 내침식성은 크롬 함량이 증가함에 따라 향상되는 특성을 가지는데, 본 연구에서는 이러한 크롬 내화재의 물성을 보다 향상시키기 위하여 인산염 화합물인 $AlPO_4$를 첨가하는 실험을 진행하였으며, 이러한 실험 결과 선정된 $AlPO_4$ 1% 첨가 크롬 내화재를 대상으로 캐스타블 및 브릭 형태로 각각 제작하였을 때 내침식 특성에 대해 회전 침식 시험장치를 이용한 실험을 실시하였는데, 실험 결과 캐스타블에 비해 브릭 내화재가 내침식성이 우수하지만 일부 spalling이 발생하는 것으로 파악되었다. 그리고, 가스화기로의 석탄 공급 방식에 따라 내화재 벽면에서 발생하는 석탄입자에 의한 내화재 침식 정도에 대한 전산해석을 수행한 결과 top feeding에 비해 side feeding 방식이 내화재 전면에 걸쳐 침식 현상이 크게 발생할 것으로 예측되어 보다 크롬 함량이 많은 내화재를 선정해야 할 것으로 평가되었다.

  • PDF

Experimental Study on Fire Resistance Performance of Legal Slab under Standard Fire with Loading condition (표준화재 재하조건에서 법정슬래브의 내화성능에 관한 실험적 연구)

  • Cho, Bum-Yean;Yeo, In-Hwan;Kim, Heung-Youl;Min, Byung-Yeol;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.115-118
    • /
    • 2011
  • 본 연구에서는 현재 법정내화구조로 규정되어 있는 철근콘크리트(RC: Reinforced concrete)조 및 철골철망모르타르(SWM: Steel & Wire Mortar)조 슬래브에 대하여 재하조건에서 구조별 내화성능을 검토하고, 철골철망모르타르조 슬래브에 대해서는 피복두께별 내화성능을 검토하고자 표준화재조건에서 내화실험을 실시하였다. 실험결과 동일피복 두께일 경우 철근콘크리트조 슬래브가 내화성능이 우수한 것으로 나타났으며, 철골철망 모르타르조 슬래브의 경우 피복두께가 10mm 증가 시 7%의 내화성능이 향상되는 것으로 나타났다. 가열 이면온도는 슬래브의 두께가 늘어날수록 낮은 것으로 나타났다.

  • PDF

Evaluation on the Thermal Resistance Capacity of Fire Proof Materials for Improving Fire Resistance of Near-Surface-Mounted FRP in Concrete (콘크리트내에 표면매입 보강된 FRP의 내화성능 향상을 위한 내화단열재 열저항성능 평가)

  • Yeon, Jea-Young;Seo, Soo-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.51-58
    • /
    • 2014
  • This paper presents a fire exposure test result to evaluate fire resistance capacity of retrofit method using FRP (Fiber Reinforced Polymer) in reinforcement concrete structure. Especially, this paper focused on near-surface-mounted retrofit method; FRP is mounted into the groove after making a groove in concrete. In the test, main parameters are retrofit method and materials for fire proofing. Spray type of perlite and board type of calcium silicate were considered as external fire proof on surface while particle of calcium silicate and polymer mortar as internal one in groove. By increasing the temperature of inside heating furnace, the transfer of temperature from surface of fire proofing material to groove in specimen was measured. As a result, fire proofing using the board of calcium silicate was more effective to delay the heat transfer from outside than spraying with perlite. It was found that the fire proofing could resist outside temperature of $820^{\circ}C$ at maximum to keep the temperature of epoxy below glass transit temperature (GTT).

An experimental study on the fireproof performance of fire damper in accordance with insulation conditions on the coaming and blade (코밍 방열 두께 및 블레이드 방열 유무에 따른 방화 댐퍼의 내화성능에 관한 실험적 연구)

  • Choi, Tai-Jin;Kim, Joung-Sik;Choi, Kyeong-Kwan;Lim, Young-Soo;Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.431-437
    • /
    • 2013
  • In this paper, Fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade is an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.