Seismic Response Estimation of Water Extinguishing Facilities using Shaking Table Tests (진동대 실험을 통한 수계 소화설비의 지진응답평가에 관한 연구)

  • Nam, Min-Jun;Park, Seung-Hee;Kim, Dong-Joon;Choi, Jun-Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.9-18
    • /
    • 2012
  • In this study, a shaking table test was performed for the evaluation of water extinguishing facilities. Water extinguishing facilities, such as a general pipe, a seismic pipe (Loof type) and a pump, were used in the experiment. This captured the dynamic characteristics of water extinguishing systems by earthquake records at El-Centro with a 50%, 70%, 100%, 120% level. As a result, seismic type facilities have excellent seismic performance compared to general facilities. By using the acceleration response spectrum, not only is the performance evaluation of water extinguishing facilities able to be determined, but also the deformation of facilities in low earthquake levels can be known. This proposed approach can determine the seismic performance evaluation of water extinguishing facilities and verify seismic performance criteria.

Fragility Analysis for Evaluation and Comparison of Seismic Performance of Building Structures (취약도 해석을 통한 빌딩구조물의 내진성능 비교 및 평가)

  • Park, Joo-Nam;Choi, Eun-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.11-21
    • /
    • 2007
  • Potential damage and losses associated with structural systems caused by earthquake can be reduced by application of seismic design to the structures. Because the building cost required for seismic design is generally higher than the cost for non-seismic design, the application of seismic design must be justified considering both seismic performance and cost. This paper presents a risk-based fiamework for evaluation and comparison of seismic performance of structures such that necessary data can be supplied for decision making on seismic design. Seismic fragility curve is utilized for seismic risk assessment of structures, and the process for decision analysis on adaptation of seismic design is presented based on the equivalent cost model.

Proposal and Performance Verification of a Seismic Adapter for Steel Brace Connections for In-plane Reinforcement of School Buildings (학교 건축물의 면내보강을 위한 강재브레이스 접합용 내진어댑터의 상세 제안 및 성능검증)

  • Seokjae Heo;Lan Chung;In-Kwan Paik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.162-171
    • /
    • 2023
  • In this study, The details for a seismic adapter designed to easily connect concrete structures and reinforcement materials for the in-plane reinforcement of aged structures were proposed. Proposed seismic adapter was tested for performance using a dynamic simulation on a 2-story column-beam structure, scaled to half of the real size. The experimental results showed that the reinforced test specimens using the seismic adapter improved their energy dissipation capacity by 3.5 times compared to the non-reinforced specimens. It was confirmed that the seismic adapter experienced no damage within its general usage range, thus proving its effectiveness. Subsequently, upon loading until the limit of deformation (a deformation angle of 3.3%), it was observed that one of the M10 bolts connecting the adapter and the reinforcement at the lower part of the first floor broke. Considering this finding, when applying seismic retrofitting in real situations, emphasis should be placed on the design of the bolts and anchors connecting the seismic adapter. This aspect warrants further research for validation.

A Study on the Status of Low-rise Buildings (국내 저층 건축물의 현황에 관한 고찰)

  • Park, Hong-Shin
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.28-28
    • /
    • 2011
  • 국내의 건축물에 관한 통계정보는 국토해양부에 의해서 공표된 통계연보로서 2002년부터 매년마다 제공되고 있다.(국토해양통계누리, https : //stat.mltm.go.kr/potal/stat/yearReport.do) 건축물의 통계연보는 과거부터 2002년까지 매 3년마다 공표된 것으로 알려지고 있다. 이 통계연보에는 건축물 현황과 건축허가착공 통계가 수록되어 있다. 건축물 현황에는 2009년 말을 기준으로 기존 건축물이 전체 6,618,131동으로서 용도별, 층수와 연면적별 그리고 소유구분별 등의 구분에 따라 건축물의 동수에 관한 통계자료가 포함돼 있다. 건축허가 및 착공통계에는 용도별과 구조재료별의 분류에 따라 건축물의 동수에 관한 자료가 신축, 증축 개축 이전 대수선, 용도변경 등으로 분류되어 수록돼 있다. 한편 국내에서 건축물에 대한 내진설계기준이 1988년에 제정됨에 따라 법제화되었다. 이때 내진설계의 의무 대상건축물은 6층 이상 또는 연면적 1만$m^2$이상인 건축물로 규정되었다. 그 이후 내진설계 대상 건축물이 1996년부터 아파트는 5층 이상으로, 판매시설은 연면적 5천$m^2$이상으로 확대되었고, 2000년부터 숙박시설 오피스텔 및 기숙사는 5층 이상으로 확대되었으며, 2005년부터 내진설계 의무화 대상이 3층 이상 또는 1천$m^2$이상으로 확대되었고, 2009년부터 3층 이상 건축물의 구조안전의 확인을 위한 세부절차를 규정하여 내진설계의 실효성을 확보하고 있다. 이와 같이 내진설계의 대상 건축물이 내진설계기준을 제정한 이후 현재까지 시대의 흐름에 따라 6층 이상에서 5층 이상으로 다시 3층 이상으로 계속 확대되어왔다. 이런 환경에서 현재 시점에서 사용 중인 기존 건축물 중에 내진설계가 적용되지 아니한 건축물은 1988년 3월 1일 이전에 건축허가 된 건축물과 그 이후에 건축허가 된 3층 내지 5층 이하인 저층 건축물의 두 가지로 구분할 수 있다. 이들의 내진설계가 미적용 된 건축물에 대해서는 원칙적으로 내진보강 대책 수립 및 추진이 필요한 실정이다. 국내에서는 현재 지진재해대책법에 따라 지진재해로부터 국민의 생명과 재산을 보호하기 위하여 기존 시설물에 대한 내진대책을 추진하는 정책이 시행되고 있다. 앞으로는 이 정책의 일환으로 기존 건축물의 내진성능 확보를 위한 내진보강 대책이 구체적으로 추진될 전망이다. 이와 같이 기존 건축물에 대한 내진보강 대책을 수립하는 데는 무엇보다 그 대상 건축물의 수와 구조형식에 관한 정보가 필요하다. 이는 내진보강의 방법과 소요비용이 건축물의 층수 및 구조형식별 동수에 따라 크게 달라지기 때문이다. 이런 관점에서 살펴볼 때 내진대책의 수립에 필수인 기존 저층 건축물의 층수 및 구조형식별 동수에 관한 통계자료를 현재 건축물의 현황통계에서 손쉽게 찾아 볼 수 있으면 좋겠는데 현실은 그렇지 못한 실정이다. 현재 건축물의 현황통계에는 저층 건축물에 해당하는 층수에 관한 구분이 연대에 따라 다르고 구체적인 층수를 구분하기 어렵게 불분명한 항목으로 구성된 것과 구조형식별 분류항목이 없는 형편이다. 반면에 건축허가 및 착공통계자료에는 구조재료별 건축물 동수와 연면적에 관한 자료가 수록되어있고, 건축물 층수에 따라 분류된 통계자료는 없다. 이 연구에서는, 기존 건축물에 대한 내진보강 대책을 수립하는데 필요한 저층 건축물의 층수 및 구조재료별 동수 등에 관한 구체적인 정보를 파악하기 위하여, 건축물 통계연보에 수록된 건축물 현황통계자료에서 불명확하거나 결여된 정보를 건축허가 및 착공 통계자료로부터 얻은 정보로 보완과 보충하여 제시하고 있다. 따라서 이 연구는 기존 건축물의 내진보강 대책 수립에 필요한 5층 이하의 저층 건축물에 관한 층수별 및 구조형식별 동수에 관한 연도별 통계자료를 추정하여 제안하는데 그 목적이 있다.

  • PDF

Seismic Performance Preliminary Evaluation Method of Reinforced Concrete Apartments with Bearing Wall system (기존 철근콘크리트 벽식 공동주택의 내진 성능 예비 평가법에 관한 연구)

  • Chung, Lan;Woo, Sung-Sik;Choi, Ki-Young;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.293-300
    • /
    • 2007
  • In Korea, the seismic design regulations was established since 1988 about regularity scale of structures. However, It was not established about seismic performance and evaluation method as the most existing buildings was constructed before Earthquake-Resistant Design(1988). In this study, for model structures which are 4 units of non-seismic designed apartment and 3 units of seismic designed in Korea performed seismic performance evaluation by suggested KISTC (2004). And the result compare to evaluate Capacity Spectrum Method by using MIDAS Gen and SDS. As a result, we observed that suggested KISTC's method have overestimated for shear stress and drift index. The purpose of this study provides most conformity seismic performance evaluation process and the appropriate method of calculating the seismic performance index in Korea.

Estimation of Seismic Performance and Earthquake Damage Ratio of Existing Reinforced Concrete Buildings in Japan (일본의 기존 철근콘트리트건물의 내진성능 및 지진피해율의 평가)

  • 이강석;이리형
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.1
    • /
    • pp.63-74
    • /
    • 2000
  • The main objective of this paper is to apply as the basic data for development of a methodology to discuss the future earthquake preparedness measures in Korea by investigating the concept and applicabilities of the Japanese Standard for Evaluation of Seismic Performance of Existing RC Buildings developed in Japan among the methodologies of all the countries of the world. This paper describes the seismic performance, Is-index, of existing RC buildings in Tokyo, Japan evaluated by the Japanese Standard, also the relationships between Is-index distribution of existing RC buildings in Tokyo and that of Shizuoka and Chiba Prefecture reported already in reference[4][5][6] are investigated. And from the comparison with Is-index to buildings damaged by earthquakes experienced in Japan, the damage ratio due to severe earthquake of 3 districts mentioned above is estimated based on the probabilistic point of view. The results of this study can be utilized to identify urgently required earthquake preparedness measures with highest priority in existing RC buildings, and the methodology to evaluate the seismic performance of existing RC buildings in Japan, statistics analysis method and the methodology to estimate earthquake damage ratio based on the probabilistic point of view shown in this study can be recommended to develop a methodology to discuss the future earthquake preparedness measures in Korea.

  • PDF

Decision Making of Seismic Performance Management for the Aged Road Facilities Based on Road-Network and Fragility Curve (취약도곡선을 이용한 도로망기반 노후도로시설물 내진성능관리 의사결정)

  • Kim, Dong-Joo;Choi, Ji-Hae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.94-101
    • /
    • 2021
  • According to the Facility Management System (FMS) operated by the Korea Authority of Land & Infrastructure Safety, it is expected that the number of aging facilities that have been in use for more than 30 years will increase rapidly to 13.9% in 2019 and 34.5% in 2929, and end up with a social problem. In addition, with the revision of "Common Application of Seismic Design Criteria" by the Ministry of Public Administration and Security in 2017, it is mandatory to re-evaluate all existing road facilities and if necessary seismic reinforcement should be done to minimize the magnitude of earthquake damage and perform normal road functions. The seismic performance management-decision support technology currently used in seismic performance management practice in Korea only determines the earthquake-resistance reinforcement priority based on the qualitative index value for the seismic performance of individual facilities. However with this practice, normal traffic functions cannot be guaranteed. A new seismic performance management decision support technology that can provide various judgment data required for decision making is needed to overcome these shortcomings and better perform seismic performance management from a road network perspective.

원자력發電所의 耐震設計용 入力 地震의 決定

  • 서정희
    • Journal of the KSME
    • /
    • v.20 no.5
    • /
    • pp.387-391
    • /
    • 1980
  • 일반적으로 내진 설계라 함은 지진에 의하여 발생된 지진동이 특정한 구조물에 작용할 때 이 지 진동의 경향하에서도 구조물의 정상적인 기능을 추진할 수 있도록 설계하는 것을 말하는 바, 원자력발전소의 내진설계에 있어서도 원칙적으로는 동일한 개념이나 실시하는 규정이 타구조물에 비하여 훨씬 엄격한 것이 다른 점이라 하겠다. 현재 우리나라의 경우 원자력 발전소는 1기(고리 #1)가 가동중이고 2기(월성 #1, 고리 #2)가 거의 완공단계에 있으며 7기(고리 #3, #4, 월성 #2, 계마 #1, #2, 부구 #1, #2)가 건설작업중인 바 이중 부구의 경우만 프랑스(\ulcorner)에서 건설 예정이고 기타는 모두 미국 및 카나다에서 건설하였거나 건설 예정이므로 따라서 그 설계에 있어서도 제 규정은 대체로 미국것을 준용하고 있는 형편이다. 그러므로 본고에서 는 미국에서 시행되고 있는 방법 또는 규정에 의거하여 내진설계용 입력지진에 대하여 설명하고자 한다. 내진설계에 입력 으로 사용되는 지진을 설계기준지진(design basis earthquake, DBE)이라고 통칭하며 이 지진은 미국 규정에 의하면 응답스펙트럼(response spectrum)으로 정의되게 되어 있으며 또한 이 응답 스펙트럼에 준하는 인공정인 지진의 시간기득(artificial time history)을 작성 또는 선정하여 이를 발전소 구조물의 내진 해석 및 내진 시험 입력으로 사용하게 되어 있다.

  • PDF

A Consideration of Seismic Design Technologies for Telecommunication Equipment (Rack) (장치(랙) 내진설계 기술에 대한 고찰)

  • Han Jin-Woo;Woo Byung-Soo;Kang Wang-Kyu
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.122-127
    • /
    • 2006
  • 최근 일본에서 발생한 지진이 우리나라에 직접적인 영향을 끼치는 등 더 이상 우리나라도 지진에 안전한 나라가 아니라는 것이 입증되고 있으며, 과도한 지진 발생시 통신두절에 따른 파급효과를 감안할 때, 이제는 본격적으로 통신시설물에 대한 내진대책을 강구할 필요가 있다. 통신시설물은 크게 통신빌딩(전화국 건물), 옥내시설(통신설비, 전원설비, 기계설비), 옥외시설(통신구, 관로 및 맨홀, 철탑, 위성안테나, 전주 등)로 구분하는데, 통신빌딩을 제외하고는 확실한 내진규정이 없는 실정으로 지진에 가장 민감한 시설로 옥내시설의 통신설비인 장치(랙)으로 알려져 있다. 따라서, 본 논문에서는 치국의 장치(랙)에 대한 내진실험 및 기준을 고찰하였으며, 이를 토대로 우리나라에서 적용할 수 있는 장치(랙)의 내진성 확보 방안을 제시하였다.

  • PDF

Seismic Performance Evaluation of Sprinkler Facilities throughout Shaking Table Test (진동대 실험을 통한 스프링클러 설비의 내진성능 평가)

  • Nam, Min-Jun;Park, Seung-Hee;Kim, Dong-Jun;Yoon, Jong-Ku;Seo, Choon-Gyo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.54-57
    • /
    • 2012
  • 지진에 의한 2차 피해 중 화재로 인한 피해가 거의 대부분이다. 따라서, 소화설비의 내진설계는 반드시 필요하며 소화능력을 유지해야 한다. 본 연구에서는 진동대 실험을 통하여 스프링클러 설비의 내진성능을 평가하였다. 스프링클러 설비의 내진성능을 평가하기 위하여 일반 설비와 내진처리가 된 설비를 동시에 시공하여 그 성능을 평가하였다. 또한, 시설물의 거동특성을 파악하기 위하여 시설별 변위응답, 가속도 응답, 가속도 응답스펙트럼을 통하여 시설물에 대한 내진성능을 평가하였다.