• Title/Summary/Keyword: 내부 홀

Search Result 142, Processing Time 0.027 seconds

Corrosion Assessment of In-pipe using Magnetic Flux Leakage Technique (누설자속법을 이용한 배관내부 부식 평가)

  • 이원용;이병주;양성일;김영주;안봉영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.402-402
    • /
    • 2000
  • MFL(Magnetic Flux Leakage) methods are used extensively for inspection of ferromagnetic materials. As an example, pipelines that are buried underground are inspected using MFL methods. By the MFL methods, ferromagnetic pipelines are magnetized by a permanent magnet or an electromagnet and then flux leakage is detected at the defection position. In this paper, we perform modeling of the magnetized pipelines. Also we propose the method localization of th defected areas. The effectiveness of the proposed method is verified experimentally.

  • PDF

Research of detect of the object in stainless pipe using the magnetic inductance (자기인덕턴스를 이용한 Stainless Steel 배관 내 이물질 검사에 대한 연구)

  • Joo, Gun-June;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.179-181
    • /
    • 2006
  • 각 원자력 발전소에서는 정밀성, 안전성을 확인하는 검사의 중요성을 인식하여 LPMS(Loose Part Monitoring System)을 사용하여 사고 징후를 조기에 감지하여 이에 대한 예방조치를 가능케 함으로써 설계기준 사고 발생을 사전에 방지할 수 있게 한다. 또한 이 기술은 신호 측정 및 분석 등의 기반기술 개발을 통하여 건전성 감시 기술의 신뢰성을 향상 시키고 있다. LPMS(Loose Part Monitoring System)기술은 재료, 기기, 구조물 등의 성질과 내부조직을 변화시키거나 파괴하지 않고, 배관내부에 흐르는 금속 파편들을 찾아내어 정밀성, 안전성, 신뢰성을 확보하기 위하여 검사기술이 적용되고 있다. 그러나 이 방법은 배관내의 이물질의 충격이 발생해야 감지가 가능하고, 이물질의 모양이나 사이즈를 확인하기에는 어려움이 있다. 따라서 본 논문에서는 배관외부에서 자기장을 인가하여, 배관내의 이물질에 변화하는 자기장을 홀센서로 측정하여 기존의 LPMS 방식을 보완하는 시스템을 개발하기 위해, 배관에 필요한 자기장 발생장치를 설계하고, 이물질을 검출하기 위한 검출 감도향상에 대해 연구하였다.

  • PDF

Trip for Photos with Stories - Mon Amour cafe the Green (이야기가 있는 사진 여행 - 모나무르 카페 더 그린 (아산))

  • Kim, Chang Gil
    • Korean Architects
    • /
    • s.657
    • /
    • pp.126-127
    • /
    • 2023
  • 10월 정기 답사 일정으로 아산 외암리 민속마을을 답사하고, 두 번째 일정으로 충남과학교육원을 답사했다. 아주 우연히, 바로 옆 '모나무르 카페 더 그린'이 괜찮은 카페라고 소개받아 추가로 답사를 했는데 건축물의 외관을 보았을 때는 별로 흥미를 느끼지 못했다. 그러나 반전이 있었다. 내부로 진입했을 때 건축물로 둘러싸인 내부에 중정으로 만들어진 워터가든에서는 놀라운 풍경이 그려지고 있었다. 중정에 설치된 워터가든을 에워싼 건축물은 카페, 예식홀 등 복합문화공간으로 구성돼 있어 관람객은 모두 워터가든과 곳곳에 설치된 조각, 예술품을 관람할 수 있으며, 자연 풍경도 같이 즐길 수 있었다. 많은 사람들이 즐기는 풍경을 보니 무척 재미있는 공간이라는 생각이 들었고, 이를 디자인한 건축사의 영감이 그렇게 부러울 수가 없었다. 우리는 주로 어떤 목적지를 선정해 답사를 하지만, 이처럼 예정에도 없었던 건축물과 풍경을 만나게 되면 답사의 즐거움이 배가 되는 기쁜 경험을 하게 되어 다시 다음 답사 일정이 기대된다.

  • PDF

Numerical Analysis on Plasma Particles inside Electro-magnetic Field Using Particle-in-cell Method (Particle-in-cell 기법을 이용한 전자기장내 플라즈마 입자의 거동 해석)

  • Han, Doo-Hee;Joe, Min-Kyung;Shin, Junsu;Sung, Hong-Gye;Kim, Su-Kyum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.11
    • /
    • pp.932-938
    • /
    • 2017
  • Particle-in-cell method which blends Eulerian grids and Lagrangian particle is utilized to solve simplified hall-effect thruster. Since this study individually tracks not only neutrons and ions but also electrons, message passing interface(mpi) scheme is adopted for parallel computer cluster. Helical movement of an electron cloud in constant magnetic field is validated comparing with an exact solution. A plasma in radial magnetic field and axial electric field in a reaction cylinder is established. Electrons do double helix movement and are well anchored in a cylinder. Ionization of neutrons by impact with high-speed electrons generates ion particles. They are accelerated by axial electric field, which forms a plume of a plasma-effect thruster.

Effect of Center Pin in Free Fall Test for a Cylindrical Li-ion Cell (원형 리튬 전지의 센터 핀이 낙하 충격에 미치는 영향)

  • Kim, Simon;Lee, Young Shin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.6
    • /
    • pp.639-644
    • /
    • 2015
  • A cylindrical secondary Li-ion cell is a device in which stored chemical energy is converted to electrical energy via an electrochemical reaction. These cells are widely used for applications that require high capacity and rate power, such as notebooks, power tools, and electric vehicles. The role of a center pin is to retain the channel for gas release, preventing blockage of the hollow of the jelly roll during a charge-discharge cycle, and to prevent an internal short circuit for tearing of separator under mechanical free fall. In this paper, two experiments are conducted with and without the center pin to experimentally verify the importance of the role of the center pin. The first experiment is a 50-cycle charge-discharge cycle test, and the second is a free fall test conducted according to the Underwriters Laboratories (UL) standards. Based on these experiments, we demonstrate that the center pin in a cylindrical cell is a very important component in terms of safety.

NDE of the Internal Hole Defect of Dental Composite Restoration Using Infrared Lock-In Thermography (위상잠금 열화상기법을 이용한 치과용 복합레진 수복재의 내부 홀 결함에 대한 비파괴평가)

  • Gu, Ja-Uk;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.40-45
    • /
    • 2013
  • The purpose of this study was to detect the pin hole defect of dental composite restoration using lock-in thermography method. Amplitude and phase images of the composite resin specimens were analyzed according to the lock-in frequency and the diameter of defect area. Through the amplitude image analysis, at lock-in frequency of 0.05 Hz, defect diameters 2-5 mm exhibited the highest amplitude contrast value between defective area and sound area. The lock-in frequency range of 0.3-0.5 Hz provided good phase angle contrast for the defect area. At lock-in frequency range of 0.5 Hz, defect diameter of 5 mm exhibited the highest phase contrast value. It is concluded that the infrared lock-in thermography method verified the effectiveness for detecting the pin hole defect of dental composite restoration.

Behavior of C-Shaped Beam to Square Hollow Section Column Connection in Modular Frame (모듈러 골조의 각형강관 기둥과 C형강 보 접합부의 거동 평가)

  • Lee, Sang Sup;Park, Keum Sung;Hong, Sung Yub;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.471-481
    • /
    • 2015
  • Modular building is a prefabricated construction system for building where factory-produced pre-engineered modular units are delivered to site and assembled as substantial elements of a building. There are two basic kinds of modular structures. One is a load-bearing wall structure designed to transfer the load through longitudinal walls. The other is a frame structure composed of columns and beams. For frame structure, square hollow section is often used as a column member and channel as a beam member in modular unit. Lower and upper modules are fasten with bolts via a pre-installed access hole in the SHS column. However, the access holes can weaken the panel zone that would affect the behavior of beam to column connection. The 5 specimens of beam to column connections with parameters of access hole, column thickness and diaphragm were made and this paper describes the test results.

Selection of Scale Model Materials for Acoustical Evaluation of 1:50 Multipurpose Halls (1:50 다목적홀의 음향평가를 위한 축소모형재료의 선정)

  • Jeon, Jin-Yong;Kim, Jeong-Jun;Kim, Yong-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.781-789
    • /
    • 2009
  • The absorption coefficients of the materials used in a 1:50 scale model multipurpose hall were measured based on ISO 354 and related laws. The shape and materials for the scale model were evaluated based on reflective surfaces, variable acoustic elements and sound-absorbing quality (125Hz-1kHz average) of seats. The measured average absorption coefficients of audience seats, audience and orchestra were 0.64, 0.74 and 0,45, respectively, which were simulated with the combination of wood, absorption materials and foam board. Various mounting methods for absorption curtain and banner were considered according to the installation methods. The average absorption coefficient was measured as 0.42, 0.47 and 0.45 in the conditions of Type A mounting, E mounting with 0.9 m backing air cavity, and Type G mounting which is suspended at the ceiling, respectively. It was confirmed that the absorption coefficient was increased at low frequency by backing air gap. The finishing material of stage house was an absorption material covered with thin fabric, which aimed average absorption coefficient of 0.68 by using fiber glass board. Each part of the real materials was compared with those of 1:50 scale model and it was found that the absorption characteristics of both cases were similar.

Analysis of Sound Attenuation by Chambers in Duct Systems by the Finite Element Method (유한요소법에 의한 소음기의 감음특성해석)

  • 최석주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.23-27
    • /
    • 1991
  • 각종 홀 (음악홀, 극장, 사무실건물)의 공조 덕트계에는 미로형소음챔버가 설 치되는 경우가 많다. 이러한 소음장치를 건물내부에 설치하는 경우에는 건물 설계단계에서부터 소음챔버로 인한 감음양(투과손실 : Transmission Loss)의 예측계산이 중요하다. 그렇지만, 일반적인 소음장치는 그 형상이나 내표면의 흡음조건이 아주 복잡하기 때문에, 현단계에서는 간단한 이론만으로 투과손 실예측이 거의 불가능하다. 지금까지 이 문제에 대해서 유한요소법(Finite Element Method : FEM)을 이용해 검토한 예가 종종 소개되었으나, 대부분 소음챔버의 입구와 출구에서의 임의의 점에 대한 음압비를 투과손실로서 구 하고 있다. 그러나, 소음기자체의 실질적인 투과손실특성을 알기 위해서는 소음기의 입력 파워에 대한 출력파워의 비로서 구하지 않으면 안된다. 따라 서, 본 연구에서는 유한요소법에 의한 복소음향인텐시티(Complex sound intensity)의 수치계산법을 각종소음기 (팽창형, 미로형)의 투과손실해석에 적 용하기 위하여 이론적인 면에서 고찰했으며, 프로그램도 개발하여 모델해석 에 적용하였다. 또한, 위에서 언급된 수치해석법의 타당성의 검증을 위하여, 측정에 의한 투과손실예측방법으로서 크로스스펙트럼(Cross Spectrum)법에 의한 음향인텐시티계측법의 이용에 대해서 이론적으로 고찰했으며, 그 이론 을 기초로 한 축척 모형실험을 병행하였다.

  • PDF

A study about frequency domain analysis of impact-wave for detecting of structural defects in the concrete structure (구조물의 안전진단을 위한 충격파의 주파수 영역 탐사에 관한 연구)

  • Suh Baeksoo;;Kim Hyoungjun;Lee Sangchul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.165-180
    • /
    • 2005
  • Impact seismic wave test is a method for nondestructive testing of concrete structure using of stress wave which is propagated and reflected from internal flaws within concrete structure and external surface, In this study, we performed non-destructive testing using impact seismic wave test for safety diagnosis of civil engineering structures. For this, I've compared and analized the result in the way of reflective method mostly using on one-dimension such as tunnel lining, and penetration method using the way of cross hole and tomography.

  • PDF