• Title/Summary/Keyword: 내부감쇠

Search Result 184, Processing Time 0.021 seconds

An Assessment of Elastic and Damping Material Properties of PVC/MBS by an Acoustic Resonance Method (음향공진법을 이용한 PVC/MBS의 탄성 및 감쇠 특성 평가)

  • 박명균;박세만;최영식;박상규
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.10
    • /
    • pp.766-772
    • /
    • 2002
  • In this investigation, experimental attempts were made to observe and determine the variations in elastic and damping properties of the PVC depending on the amounts of MBS added to the mixture, PVC/MBS, and also on the thicknesses of the specimens. An acoustic resonance technique was used for the tests In this investigation. It serves as a method to characterize properties of materials set in vibrational motions, which is initiated by low level stresses generated by externally supplied acoustic energy. Substantial variations were observed in the test results with the addition of the MBS to the PVC. It was found that the magnitudes of elastic constants decrease while the damping capacity improve when MBS rubber was added in the range up to 9 phr.

Effect of Microstructure on the Damping Capacity of 12Cr Martensitic Heat-resisting Steel (12Cr 마르텐사이트계 내열강의 감쇠능에 미치는 미세조직의 영향)

  • Lee, S.M.;Kang, C.Y.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.78-83
    • /
    • 2010
  • This study was carried out to investigate the effect of microstructure on the damping capacity of 12Cr martensite heat-resisting steels, in case of the specimen with martensite phase contained the volume faction of ferrite phases, under 5%. The damping capacity was decreased with the increase of solution treatment temperature and time. While it was increased with the increase of tempering temperature and time. The damping capacity was higher in case of specimen with martensite single phase structure than the specimen with martensite phase contained of ferrite phases.

Iterative Teconstruction of a Cylinder Buried in the Lossy Half Space (손실 반공간에 묻힌 원통형 산란체의 검출 및 영상제구성에 의한 식별)

  • 김정석;나정웅
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.939-945
    • /
    • 2000
  • A cylindrical object buried in the lossy half space is reconstructed from the measured scattered fields above the lossy half space. The position, the size and the medium parameters i.e. relative dielectric constants and conductivity of the buried object as well as the medium parameters of the background lossy half space are obtained from the scattered fields by using the iterative inversion method and the optimization hybrid algorithm combining the genetic algorithm and the Levenberg-Marquardt algorithm. Illposedness of the inversion due to the measurement errors in the scattered fields are regularized by filtering out the evanescent modes in the spatial frequency spectrum domain.

  • PDF

An Analysis of Intensity Attenuation Characteristics by Physics-based Strong Ground-Motion Simulation (물리적 지진모델링 기반 강지진동 모사를 통한 진도 감쇠 특성 분석)

  • Kim, Su-Kyong;Song, Seok Goo;Kyung, Jai Bok
    • Journal of the Korean earth science society
    • /
    • v.40 no.1
    • /
    • pp.56-67
    • /
    • 2019
  • In this study, we analyzed the intensity attenuation for M 6.0, 6.5, and 7.0 earthquakes using the broadband strong ground motion simulation platform based on the physical seismic modeling developed by the US Southern California Earthquake Center (SCEC). The location of the earthquake was assumed to be near the epicenter of the 2016 M 5.8 Gyeongju earthquake, but two of the representative US regional models provided by the SCEC strong ground motion simulation platform were used for the propagation model. One is the Central and Eastern United States (CEUS) model representing the intraplate region, and the other is the LA Basin model representing the interplate region. Five modeling methodologies are presented in the version 16.5 of the simulation platform, and Song and Exsim models were used in this study. In the analysis, we found that different intensity attenuation patterns can be observed with the same magnitude of earthquakes, especially depending on the region (CEUS vs LA Basin). Given the same magnitude and distance, the instrumental intensity in the CEUS region (intraplate) could be larger by a unit of 2 than that in the LA Basin region (interplate). Given the difference of intensity attenuation patterns observed in the study, it is important to know the regional intensity attenuation characteristics to understand the accurate level of seismic hazard imposed in the Korean Peninsula. This study also shows the level of the uncertainty of intensity attenuation if region specific attenuation characteristics are not considered.

Vibrational Properties of High Damping Polymer Concrete with Hybrid Damper (복합구조 댐퍼를 적용한 고 감쇠 폴리머 콘크리트의 진동 특성에 관한 연구)

  • Kim, Jeong-Jin;Choi, Kyung-Suk;We, Joon-Woo;Seok, Won-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.135-142
    • /
    • 2020
  • In the case of a concrete structure, vibration problems occur under various conditions because of its low damping performance. To solve this problem, a study on the high damping performance of the polymer concrete with hybrid damper has recently been increased. Since water is not used in polymer concrete, the curing time is short. Also, the physical properties and dynamic properties of polymer concrete are quite excellent. So polymer concrete is widely expected to be used for structural materials. The hybrid damper is the structural system that consists of steel balls and viscous fluid inside the pipe which is embedded in polymer concrete. It can reduce the structural vibrations through the energy dissipation mechanism of viscous fluid and steel balls. In this study, the physical and dynamic properties of polymer concrete with hybrid damper were compared with ordinary concrete. As a result, the elasticity coefficient and the strength of the polymer concrete with hybrid damper were so much excellent. In particular, the tensile strength was 6.5 to 10 times higher than ordinary concrete. The frequency response function and damping ratio were also compared. As a result, the dynamic Stiffness of the polymer concrete was 25% greater than that of ordinary concrete. The damping ratio of the polymer concrete was approximately 3 times higher than that of ordinary concrete. Although the dynamic stiffness of the hybrid damper showed similar tendency, the damping ratio was 3.5 times higher than that of ordinary concrete. Therefore, the polymer concrete with hybrid damper was superior to ordinary concrete.

Comparison of Dynamic Property Estimation by Transient Vibration and Synchronized Human Excitation (건물의 상시진동계측과 인력가진계측을 통한 동적특성 비교)

  • Jang, Young-Ju;Cho, Bong-Ho;Kim, Hong-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.259-266
    • /
    • 2011
  • The transient vibration test and synchronized human excitation is performed for low-rise concrete buildings and their identified natural frequency, damping ratio, and mode shape are compared. Form the identified dynamic parameters, it was found that the damping ratio obtained through the synchronized human excitation test is greater than those obtained from the transient vibration test. However, the mode shapes of the first mode are not significantly different regardless of the test method. Further, the stiffness of the interior brick partition considerably affect the stiffness of the entire building such that the first natural mode of rectangular shaped building occurred in the longitudinal direction rather than transverse direction.

Development of Complementary Mild-slope Equation for Stream Function Over Permeable Bed (투수층에 적용 가능한 흐름함수방식의 확장형 완경사방정식의 개발)

  • Kim, Gunwoo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.6
    • /
    • pp.758-765
    • /
    • 2016
  • In this study, wave damping due to a permeable bed of finite depth was modelled using a complementary mild-slope equation for stream function. The energy dissipating term in the mild-slope equation was presented in terms of stream function. In order to prevent re-reflection of reflected waves along the outer boundary, a delta-function-shaped source function was derived to generate a wave in a computational domain. Numerical experiments were conducted to measure the reflection coefficient of waves over a planar slope for various incident wave periods. The numerical result of the proposed model was compared with that of an integral equation method, showing good agreement in general. However, the proposed model showed relatively higher transmission rate for the larger permeability and the longer wavelength.

A Study on the Attenuation of High-frequency P and S Waves in the Crust of the Southeastern Korea using the Seismic Data in Deok-jung Ri (덕정리 지진자료를 이용한 한국남동부지역 지각의 P, S파 감쇠구조 연구)

  • Chung, Tae-Woong;Sato, Haruo
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.3
    • /
    • pp.193-200
    • /
    • 2000
  • The attenuation characteristics($Q^{-1}$) are important factors representing the physical properties of the Earth interiors, and are essential for the quantitative prediction of strong ground-motion. Based on 156 earthquakes including 76 single-station record on the seismic station located Deok-jung Ri, southeastern Korea, we made the simultaneous measurement of P and S wave attenuation($Q_P^{-1}\;and\;Q_S^{-1}$) by means of extended coda-normalization method. Estimated $Q_P^{-1}\;and\;Q_S^{-1}$ decreased from $1{\times}10^{-2}\;and\;9{\times}10^{-3}$ at 1.5 Hz to $6{\times}10^{-4}\;and\;5{\times}10^{-4}$ at 24 Hz, respectively. This can be expressed by $Q_P^{-1}=0.01\;f^{-1.07}\;and\;Q_S^{-1}=0.01\;f^{-1.03}$ which indicate strong frequency dependence.

  • PDF

Numerical Analysis of Sunroof Buffeting using STAR-CCM+ (STAR-CCM+를 이용한 썬루프 버페팅 유동 소음 해석)

  • Bonthu, Satish Kumar;Mendonca, Fred;Kim, Ghuiyeon;Back, Young-R.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.213-218
    • /
    • 2014
  • CFD flow simulation of vehicles with open sunroof and passenger window help the automotive OEM(original equipment manufacturer) to identify the low frequency noise levels in the cabin. The lock-in and lock-off phenomena observed in the experimental studies of sunroof buffeting is well predicted by CFD speed sweep calculations over the operating speed range of the vehicle. The trend of the shear layer oscillation frequency with vehicle speed is also well predicted. The peak SPL from the CFD calculation has a good compromise with the experimental value after incorporating the real world effects into the CFD model by means of artificial compressibility and damping correction. The entire process right from modeling to flow analysis as well as acoustic analysis has been performed within the single environment i.e., STAR-CCM+.

Vibration Damping Ratio Performance Evaluation According to the Polymer Mixing Rate of SBR-based Polymer Modified Mortar through Ultrasonic Pulse Analysis (초음파 펄스 분석을 통한 SBR계 폴리머 혼입 모르타르의 폴리머 혼입률에 따른 진 동감쇠비 성능 평가)

  • Jeong, Min-Goo;Jang, Jong-Min;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.543-551
    • /
    • 2022
  • The mechanical performance and vibration damping ratio performance of a specimen according to the polymer mixing rate were evaluated for polymer modified mortar. As a polymer, Styrene Butadiene Rubber(SBR) liquid polymer with a solid content of about 49~51% was used, and the polymer content was increased by liquid 5%. The specimen was 40*40*160(mm), and after curing, compressive strength, flexural strength, and vibration damping ratio were measured using the ultrasonic pulse method. As a result, it was found that the compressive strength decreased as the polymer was mixed, but the flexural strength was increased. The vibration damping ratio increased by 11% at 5% polymer, 28% at 10% polymer, 33% at 15% polymer, and 72 at 20% polymer. I was found that the incorporation of the polymer was very effective to reduce the vibration of the mortar. In addition, through SEM and SEM-EDS analysis, it is determined that the cause of vibration reduction due to polymer mixing is that the polymer film formed in the transition zone of aggregate and internal voids buffered the vibration of the mortar inside. Taken together, in the scope of this study, the appropriate polymer mixing ratio for reducing the vibration of mortar is judged to be about 7.5%.