• Title/Summary/Keyword: 납 차폐

Search Result 148, Processing Time 0.022 seconds

Dose Customized Apron Micro Functional Design Using Convergence Shielding Sheet (융합 차폐시트를 이용한 선량 맞춤형 에이프런 마이크로 기능성 디자인)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.119-126
    • /
    • 2021
  • Radiation shielding clothing for medical institutions is used based on lead equivalent of 0.25 mmPb. However, this study intends to study the shielding suit that can guarantee the user's activity while considering the sensitivity of each part of the body. By manufacturing based on eco-friendly shielding material, it was attempted to solve the weight problem and environmental problem of existing lead aprons, and to present the same shielding performance as lead equivalent in thickness. The fabric of the produced shielding sheet was manufactured through a calendar process that adjusts the thickness of the shielding sheet from lead equivalent 0.12 mmPb to 0.32 mmPb. In addition, the usability evaluation of the manufactured shielding clothes was conducted for the subjects who were workers in medical institutions. As a result, the activity became easier and the weight was reduced by 0.26 kg. In the future, it is thought that it is necessary to improve the shielding suit design considering the activity.

Evaluation of the Shielding Effect of Lead Apron according to the Energy Spectrum Change of 99mTc (99mTc의 에너지 스펙트럼 변화에 따른 납 앞치마의 차폐 효과 평가)

  • Changyong Yoon;Youngsik Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.889-896
    • /
    • 2023
  • Changes in the energy spectrum were analyzed using 99mTc as a point source and a scattering phantom, and the shielding effect of the lead apron according to the changed gamma ray energy was evaluated. In the gamma ray energy spectrum of the scattering phantom, the photo peak area decreased and the compton scattering area increased compared to the point source. The coefficients for each energy range according to the change in the shape of the gamma ray source showed a reduction rate of up to 66.1 % at a distance of 20 cm compared to the coefficient of the point source, and in the compton scattering area, the coefficient of the scattering phantom was 122.2 % at a distance of up to 40 cm compared to the coefficient of the point source. In the difference in shielding rate according to the distance between the source and the scattering phantom using a gamma camera, the photo peak area showed similar results, but in the Compton scattering area, the shielding rate of the scattering phantom at a distance of 20 cm increased by 29.2 % compared to the shielding rate of the point source. As the distance increased, the difference in shielding rate decreased. In measuring the shielding rate of the lead apron using a radiation dosimeter, the difference in the shielding rate of the scattering phantom was up to 15.3 %, and as the distance increased, the difference in the shielding rate between the two sources decreased. The shielding rate of the lead apron of the scattering phantom is higher than that of the point source, and the effectiveness of the lead apron increases as the distance to the source increases. As a result, wearing a lead apron when directly confronting a patient who has injected radioactive pharmaceuticals is expected to be helpful in reducing radiation exposure.

A Study on the Lead(Pb) Shield Thickness per Electron Beam Energy in Radiotherapy (방사선 치료용 전자선의 에너지별 납(Pb) 차폐체 두께 측정)

  • Gha-Jung, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.719-725
    • /
    • 2022
  • This study aimed to measure, quantitatively evaluate, and set the criteria for the minimum lead(Pb) shield thickness per level of clinically applied electron beam energy. The lead shield thickness per electron beam energy was measured using the primary field 95% reduction based on the open field at the depth of maximum dose (dmax) and depth from the surface as the reference depth of tissue dose(10 mm). The measured values were 1.906 mmPb and 1.992 mmPb at the dmax and 10 mm, respectively, regarding the lead shield thickness for 6 MeV electron beam; 2.746 mmPb and 3.743 mmPb for 9 MeV electron beam, 3.718 mmPb and 6.093 mmPb for 12 MeV electron beam, 7.300 mmPb and 15.270 mmPb for 16 MeV electron beam, and 16.825 mmPb and 25.090 mmPb for 20 MeV electron beam. Consequently, a thicker lead shield was required if the measurement was at 10 mm. The required lead shield thickness was also higher than that of the theoretical formula for electron beams of ≥ 16 MeV.

Analysis of Lead and Bismuth Absorption Rate by Monte Carlo Simulation (몬테카를로 시뮬레이션에 의한 납과 비스무트 흡수율 분석)

  • Kim, Gap-Jung;Kim, Nak-Sang;Yoo, Se-Jong;Lee, Won-Jeong;Kim, Jeong-Ho;Hong, Seong-Il;Jeon, Min-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.419-425
    • /
    • 2022
  • In the medical field, lead aprons are used to protect the human body from radiation. However, lead is a heavy metal that is harmful to the human body and the environment, so various shield are being developed. In this study, bismuth, which has a similar atomic number to lead, was set as a new material and the absorption rate according to thickness in the same energy region was compared and evaluated through Monte Carlo simulation. The same tendency was confirmed when the thickness of the lead shield was 0.25 mm, the thickness of the bismuth was 0.3 mm, when the lead was 0.50 mm, the bismuth was 0.60 mm, and when the lead was 0.75 mm, the bismuth was 0.90 mm. Therefore, it is reasonable to replace lead with bismuth in the shield material.

Barium Compounds through Monte Carlo Simulations Compare the Performance of Medical Radiation Shielding Analysis (몬테카를로 시뮬레이션을 통한 바륨화합물의 의료방사선 차폐능 비교 분석)

  • Kim, Seonchil;Kim, Kyotae;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.403-408
    • /
    • 2013
  • This study made a tentative estimation of the shielding rate of barium compound by thickness through monte carlo simulation to apply medical radiation shielding products that can replace existing lead. Barium sulfate($BaSO_4$) was used for the shielding material, and thickness of the shielding material specimen was simulated from 0.1 mm to 5 mm by applying $15{\times}15cm^2$ of specimen area, $4.5g/cm^3$ of density of barium sulfate, and $11.34g/cm^3$ density of lead. Entered source was simulated with 10kVp Step in consecutive X-ray energy spectrum(40 kVp ~ 120 kVp). Absorption probability in 40 kVp ~ 60 kVp showed same shielding rate with lead in 3 mm ~ 5 mm of thickness, but it was identified that under 2 mm, the shielding rate was a bit lower than the existing lead shielding material. Also, the shielding rate in 70 kVp ~ 120 kVp energy band showed similar performance as the existing lead shielding material, but it was tentatively estimated as fairly low shielding rate below 0.5 mm. This study estimated the shielding rate of barium compound as the thickness function of x-ray energy band for medical radiation through monte carlo simulation, and made comparative analysis with existing lead. Also, this study intended to verify application validity of the x-ray shielding material for medical radiation of pure barium sulfate. As a result, it was estimated that the shielding effect was 95% higher than the existing lead 1.5 mm in at least 2 mm thickness of barium compound in medical radiation energy band 70 kVp ~ 120 kVp, and this result is considered valid to be provided as a base data in weight lightening production of radiation shielding product for medical radiation.

Analysis of a Lead Vest Dose Reduction Effect for the Radiation Field at Major Working Places during Refueling Outage of Korean PWR Nuclear Power Plants (국내 가압경수로형 원전 계획예방정비기간 주요 방사선작업에 대한 납 차폐복 선량저감효과 분석)

  • Kim, Jeong-In;Lee, Byoung-Il;Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.237-241
    • /
    • 2013
  • The gamma energy distributions at the major working places during refueling outage of Korean PWR nuclear power plants were measured. In order to estimate the dose reduction effect of a lead vest, Monte Carlo calculation method was used. For the simulations, the MIRD-V phantom with a lead vest was formed and exposed to the measured radiation field. The average measured gamma energy is lower than that of standard which is generally applied to radiation protection procedures. For the efficient use of a lead vest and achievement of radiation protection purpose, it is necessary to estimate the energy distribution of radiation field at working places.

Usefulness Evaluation and Fabrication of the Radiation Shield Using 3D Printing Technology (3차원 프린팅 기술을 이용한 차폐체 제작 및 유용성 평가)

  • Jang, Hui-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1015-1024
    • /
    • 2019
  • In the medical field, X-rays are essential in the diagnosis and treatment of diseases, and the use of X-rays continues to increase with the development of imaging technology, but X-rays have the disadvantage of radiation exposure. Although lead protection tools are used in clinical practice to protect against radiation exposure, lead is classified as a heavy metal and can cause harmful reactions such as lead poisoning. Therefore, the purpose of this study is to investigate the usefulness of the shield fabricated using materials of FDM (Fused Deposition Modeling) 3D printer. In order to confirm the filament's line attenuation factor, phantoms were fabricated using PLA, XT-CF20, Wood, Glow and Brass, and CT scan was performed. And the shielding sheet of 100 × 100 × 2 mm size was modeled, the dose and shielding rate was measured by using a diagnostic X-ray generator and irradiation dose meter, and the shielding rate with lead protection tools. As a result of the experiment, the CT number of the brass was measured to be the highest, and the shielding sheet was manufactured by using the brass. As a result of confirming with the diagnostic X-ray generator, the shielding rate was increased in the shielding sheet having a thickness of 6 mm upon X-ray irradiation under the condition of 100 kV and 40 mAs. It measured by 90% or more, and confirmed that the shielding rate is higher than apron 0.25 mmPb. As a result of this study, it was confirmed that the shield fabricated by 3D printing technology showed high shielding rate in the diagnostic X-ray region. there was.

Simulation of Energy Absorption Distribution using of Lead Shielding in the PET/CT (PET/CT 검사에서 납 차폐체 사용에 따른 에너지 흡수 분포에 관한 모의실험)

  • Jang, Dong-Gun;Kim, Changsoo;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.459-465
    • /
    • 2015
  • Energy absorption distribution according to lead shielding for 511 keV ${\gamma}$ ray was evaluated using a Monte Carlo simulation in PET/CT. Experimental method was performed about the depth of skin surface(0.07), lens(3) and the depth(10) was conducted by using ICRU Slab phantom. Difference of energy absorption distribution according to lead thickness and effect of air gap according to distance of lead and phantom. As a result, study showed that using a lead shielding makes high energy distribution by backscatter electron. As a distance between lead and phantom increased, energy absorption distribution gradually decreased. 9 cm or more air gap should exist to prevent effect of backscatter electron which reaches skin surface, when 0.25 mmPb shielding is used. Also 1 cm or more air gap was needed to prevent the effect in 0.5 mmPb. If air gap was not concerned, 0.75 mm or more lead thickness was necessary to prevent effect of backscatter electron.

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.