• Title/Summary/Keyword: 낙뢰시스템

Search Result 102, Processing Time 0.044 seconds

Construction of the Measuring System for Magnetic Field Waveform Associated with Lightning Return Strokes. (낙뢰에 의하여 발생되는 자계파형측정 시스템의 구성)

  • Lee, B.H.;Ha, B.C.;Kil, G.S.;Paek, Y.H.;Lee, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1658-1660
    • /
    • 1994
  • This paper describes the measurement system of the magnetic field waveforms generated by lightning return strokes. The frequency bandwidth of magnetic field measurement system is from 270[Hz] to about 2.3 [MHz]. As the application experiment, the magnetic field generated by simple impulse and oscillating impulse currents, which are measured by a current transformer (Tek. AM503), is observed by the trial magnetic field measurement system. The obtained results are agreement with each other. A typical magnetic field waveform associated with lightning return strokes was recorded and presented.

  • PDF

A study on surge state measurement with CAI method (CAI 방식의 서지상태측정 기술 연구)

  • Kim, Dong-Jin;Kim, Kwang-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.355-358
    • /
    • 2008
  • 고도의 정보화 사회로 대부분 반도체 소자로 이루어진 전기전자기기가 널리 보급되었다. 이러한 전자부품은 저전압에서 구동되고 있어 낮은 전압의 서지라도 오동작을 일으키거나 파괴될 수 있다. 이와 같이 정보통신기기는 물론 가전기기를 둘러싼 환경은 뇌 서지에 매우 취약하여 뇌 보호 대책의 필요성이 높아지고 있다. 뇌 보호 관련 규정이 KS C IEC 62305로 개정되면서 선택사항에 불과했던 내부 뇌보호 시스템인 서지보호기(SPD)가 필수사항이 되었다. 그런데 사용자들이 실제 현장에 설치하였을 때 많은 문제점이 발생되고 있다. SPD가 제대로 작동하는지의 동작상태와 경년에 따른 SPD의 특성 변화를 알 수 없다. 현재 SPD 기술은 단순한 LAMP에 의한 SPD의 소손 여부와 낙뢰 유입 횟수만 알 수 있을 뿐이다. 따라서 서지보호기에 유입되는 서지의 특성을 파악하여 대책 마련을 가능케 하여 규격에 적합한 서지보호 및 적용을 실현하고자 한다.

  • PDF

Development of Real Time Analysis System about Lightning Information (낙뢰정보 실신간 통계분석시스템 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.169-171
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission tines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

OPERATION OF LIGHTNING DETECTION NETWORK IN KOREA (국내의 낙뢰 위치 표정 시스템 운용 현황)

  • Wee, S.B.;Bae, J.H.;Cho, Y.G.;Kim, Y.S.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.186-188
    • /
    • 1993
  • This paper reports a status of KLDN(Korean Lightning Detection Network) SYSTEM in Korea, which was constructed by KMA(Korean Meteorological Administration) & KERI(Korean Electrotechnology Research Institute). At first, system configuration was introduced, and then lightning location data between August/1992 & April/1993, which was obtained in KLDN SYSTEM, was analyzed statistically. Finally, we show the future research planning in relation with this KLDN SYSTEM.

  • PDF

Development of Wireless lightning detecting and warning system (무선식 낙뢰통보시스템 개발)

  • Kim, Kyung-Man;Kwon, Tae-Woon;Sim, Kwang-Yeol;Kim, Se-Yeol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.500-503
    • /
    • 2006
  • This paper gives a Wireless lightning detecting and warning system. This system composed of transmitter and receiver. It promptly senses lightning strikes on the power lines and transmission towers by using the lightning current detection circuit in a small transmitter situated on the top of power tower, and it sends the number of lightning strikes and the ID. of the tower to patrols through the receivers. This system will be used to discover the exact location of a lightning strike.

  • PDF

Development of a Detect-and-Acquisition System for Broadband Lightning Signals (광대역 낙뢰신호 탐지 및 획득 시스템 개발)

  • Song, Seung-Hun;Kim, Dong-Hyouc;Lee, Sung-Ho;Woo, Jung-Wook;Sung, Tae-Kyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1503-1510
    • /
    • 2007
  • To implement a high-precision lightning tracking system utilizing TDOA measurements, high-speed data acquisition and precise timing synchronization between ground sensors should be achieved. At the same time, considering the size of digitizer's memory, the data memory needs to be managed so that only the sampled data around the occurrence of stepped leader pulse is stored. This paper presents a detection-and-acquisition system for lightning signals that is the main equipment of ground sensor in lightning tracking system. GPS clock module is used to get precise timing synchronization and the 500MHz high speed digitizer is employed. In order to detect the leading edge of the lightning pulse and save the sampled data and its timing, lightning detection module is implemented and multi-record method is employed in the proposed system. Field experiment results show that the proposed system can detect and save the lightning signal efficiently.

A method of minimization of output capacitor Considering transient characteristics of PFC circuit (PFC 회로의 과도 특성을 고려한 출력 커패시터 용량 최소화 방안)

  • Joo, Sungyong;Kang, Jeongil
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.151-153
    • /
    • 2020
  • PFC( Power Factor Corrector)회로의 목적은 입력전류의 역률 개선을 목적으로 널리 사용되고 있다. 그리고 입/출력 파워의 균형을 위해 대용량의 출력Cap이 사용되며 주로 전해액이 포함된 부품을 사용한다. 그러나 사용 되는 전해Cap은 AC-DC 변환회로의 수명시간을 결정지으며 이를 사용하는 전자제품의 전체 수명을 반영하게 된다. 본 연구는 출력Cap용량을 최소와시키며 이를 대체 할 수 있는 Film Cap을 사용하여 제품의 전체 수명시간을 개선시키는데 목적이 있으며 다이나믹 특성의 부하와 서지성 낙뢰 및 과전압 대책에 대한 해결방안을 실제 시스템에서 구현하고자 한다. 또한 입력 서지 및 다이나믹 부하에 대한 개선 회로를 확인하고 이론적 결과는 200W LED TV에서 검증한다.

  • PDF

Transient Response characteristics Associated with the Common Connection Points in Grounding Systems for Electric Power Utilitires (전력설비용 접지시스템에 공결점에 따른 과도응답특성)

  • 이복희;이승칠;엄주홍;심판섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.101-108
    • /
    • 1999
  • Ths paper describes the transient response characteristics of the grounding systems for electric power facilities against impluse currents. In this work, when the impulse current was injected through the grounding conductor for arrester, the investigations treasuring and analyzing potential rises induced at the cormron cormection trint and other grounding conductors were conducted. The lightning impulse current was awliErl so as to simulate the on-set of arrester due to lightning surges. Measured results of impulse response characteristics from the present experinrrits are as follows;

  • PDF

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

Efficient Integrated Real-time Discharge Measurement System Operating Strategy applying Non-face-to-face technology (비대면 기술을 적용한 효율적인 자동유량측정시스템 운영 방안)

  • Oh, Dong Heon;Baek, Jong Seok;Cho, Sang Uk;Cha, Jun Ho;Seo, Hae Yeop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.482-482
    • /
    • 2021
  • 자동유량측정시스템은 하천 유량을 실시간으로 측정하기 위한 수문조사시설로 전국 하천 64개 주요 지점에 설치·운영 중이며 실시간으로 운영되는 시스템의 특성상 내·외부 요인으로 인해 자료의 결측이 발생할 수 있다. 주요 결측 요인으로는 계측장비의 고장 및 오작동, 낙뢰로 인한 전원부문제, 시스템 컨트롤러 단순 오류 등이며, 현재 이로 인해 결측이 발생한 경우 현장 방문을 통한 조치 외에는 복구가 불가한 실정이다. 본 연구에서는 현장 유지관리 개선을 통해 자료 결측 최소화 방안을 마련하고자 최근 5년간(2015년~2019년) 수행된 유지관리 점검내역을 검토하였다. 현장 유지관리는 정기적으로 수행되는 정기점검, 수중점검과 장애 발생 시 수행되는 현장점검으로 구분되며 최근 5년간 수행된 점검(1,735회) 중 정기적인 점검을 제외한 현장점검의 경우 총 764회(46%) 수행된 것으로 나타났으며 현장점검 중 유지관리 방법 및 장비 개선 적용 사례를 통해 최소 1일~3일 소요되던 점검 시간이 즉시 조치가 가능한 것으로 나타났다. 시스템 확대 및 기존 장비의 노후로 현장점검은 지속적으로 증가하고 있으며 최근 사회적 상황을 고려하였을 때 사물인터넷(IoT)을 활용한 시설물 개선 등으로 비대면 점검 수행이 가능해짐에 따라 점검 소요시간을 단축하여 보다 효율적인 시설물 운영, 예산 절감, 자료의 연속성 확보 등이 가능할 것으로 판단된다.

  • PDF