• Title/Summary/Keyword: 깃 통과 주파수

Search Result 12, Processing Time 0.038 seconds

A Diagnosis and Solution Case of Structural Vibration caused by Pipe (배관에 의한 구조진동 진단 및 대책)

  • Lee, J.H.;Gu, D.S.;Choi, B.K.
    • Journal of Power System Engineering
    • /
    • v.12 no.2
    • /
    • pp.18-22
    • /
    • 2008
  • A few intake stations have vibration problems caused by pipes. The vibration transffered from pipes excites building severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration is measured and analysis is carried out for pipes at intake station in order to identify the usefulness and effectiveness of the solution proposed for pipe resonance avoidance. According to the result of analysis, the vibration of pipes is reduced by bellows.

  • PDF

Dynamic Characteristics of the Double Volute Double Suction Centrifugal Pump Using Measured Vibration Data (진동응답 측정에 의한 이중 벌류트형 양흡입 원심펌프의 동적특성)

  • 최복록;박진무
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.500-507
    • /
    • 2000
  • Dynamic forces due to mechanical and hydraulic related causes are always exerted on operating turbomachinery such as centrifugal pumps. To ensure the safety and the reliability of the pump. the magnitudes of the vibration must be kept within an acceptable limit. The focus of this paper is on the identification of the vibration behavior and the quantitative analysis of the hydraulic excitation forces. As the structure becomes more complex finite element analysis is essential to accurately predict the vibration characteristics and the excitation forces, This paper presents an experimental and analytical technique to find and solve to vibration problems in double volute double suction centrifugal pump. Measured vibration data due to the dynamic forces are presented and individual causes are identified, finally excitation forces of the pump are inversely estimated at each frequency on operating conditions.

  • PDF

A diagnosis and solution case of structural vibration caused by pipe (배관에 의한 구조진동 진단 및 해결 사례)

  • Lee, Jeong-Hwan;Gu, Dong-Sik;Choi, Byeong-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1371-1374
    • /
    • 2007
  • A few intake stations have vibration problems caused by pipes. The vibration transffered from pipes excites building severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration is measured and analysis is carried out for pipes at intake station in order to identify the usefulness and effectiveness of the solution proposed for pipe resonance avoidance. According to the result of analysis, bellows is reduced the vibration of pipes.

  • PDF

The Analysis of Vibration with Pump and Pipe for Intake Station (취수장용 펌프 및 배관 진동 분석 사례)

  • Choi, B.K.;Choe, C.R.;Kim, H.J.;Gu, D.S.;Jung, H.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.200-204
    • /
    • 2005
  • A few intake stations have vibration problems caused by pumps, motors and pipes. The vibration transffered from pumps, motors and pipes excites buiding severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration and noise have been measured and analyzed for pumps, motors, pipes and building at intake station. Also, the cause of vibration and noise is identified. Finally, the reference of vibration and noise is established using results of measurement.

  • PDF

Structural Vibration Analysis Caused by Piping Resonance (배관공진에 의한 구조물 진동 분석)

  • Gu, Dong-Sik;Kim, Hyo-Jung;Jeong, Han-Eol;Kim, Hak-Eun;Choi, Byeong-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.190-196
    • /
    • 2007
  • A few intake stations have vibration problems caused by pumps, motors and pipes. The vibration transferred from pumps, motors and pipes excites building severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration has been measured and analyzed for pumps, motors, pipes and building at intake station. Also, the cause of vibration is identified. Finally, the solution of structural vibration is established using the results of measurement.

A Computerized Design System of the Axial Fan Considering Performance and Noise Characteristics (성능 및 소음특성을 고려한 축류 팬 설계의 전산 체계)

  • Lee, Chan;Kil, Hyun-Gwon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.2
    • /
    • pp.48-53
    • /
    • 2010
  • A computerized design system of axial fan is developed for constructing 3-D blade geometry and predicting both aerodynamic performance and noise. The aerodynamic blading design of fan is conducted by blade angle distribution, camber line determination, airfoil thickness distribution and blade element stacking along spanwise distance. The internal flow and the aerodynamic performance of designed fan are predicted by the through-flow modeling technique with flow deviation and pressure loss correlations. Based on the predicted internal flow field and performance data, fan noise is predicted by two models for discrete frequency and broadband noise sources. The present predictions of the flow distribution, the performance and the noise level of actual fans are well agreed with measurement results.

Fan Noise Prediction Method of Air Conditioning and Cooling System (공기조화 및 냉각시스템의 팬 소음예측 기법)

  • Lee, Jin-Young;Lee, Chan;Kil, Hyun-Gwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1318-1320
    • /
    • 2007
  • Fan noise prediction method is presented for air conditioning and/or cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(Flow Network Modeling) with the flow resistances for flow elements of the system. Based on the fan operation point predicted from the FNM analysis results, the present fan noise model predicts overall sound power, pressure levels and spectrum. The predictions of the flow distribution, the fan operation and the noise level in electronic system by the present method are well agreed with 3-D CFD and actual noise test results.

  • PDF

Fan Noise Prediction Method of Air Cooling System (공기 냉각 시스템의 홴 소음 예측 기법)

  • Lee, Chan;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.952-960
    • /
    • 2008
  • Fan noise prediction method is presented for air conditioning, automobile and electronic cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(flow network modeling). Fan noise prediction method comprises two models for the discrete frequency noise due to rotating steady aerodynamic lift and blade interaction and for the broadband noise due to turbulent boundary layer and wake vortex shedding. Based on the fan operation point predicted from the FNM analysis results and fan design parameters, the present far noise model predicts overall sound pressure level and spectrum. The predictions for the flow distribution, the fan operation and the noise level in air cooling system by the present method are well agreed with 3-D CFD and actual noise test results.

A Case Study on Vibration of Vertical Pumps according to Changing Water Level (수위변화에 따른 수직형 펌프의 진동 발생 사례 고찰)

  • Song, Ae-Hee;Song, Jin-Dae;Kim, Hyeon-Sig;Jung, Gi-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.274-278
    • /
    • 2012
  • Vertical pumps are structurally weak in terms of vibration because of installed heavy motor on top of the pumps in form of cantilever. So high vibration on top of the pumps can occur with low vibration in the bottom. These vibration problems experienced very frequently. Majority of studies have been related to the unbalance of rotating parts or structural resonance. In this paper, we introduce an unusual case, vibration variation caused by VPF(Vane Passing Frequency) according to water level.

  • PDF

A Parametric Study of Aerodynamic Noise in Centrifugal Compresso (원심압축기의 공력소음에 관한 파라미터 연구)

  • Sun, Hyosung;Lee, Soogab;Lee, Jungeun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.2 s.95
    • /
    • pp.129-134
    • /
    • 2005
  • This paper describes the influence of geometric parameters on the noise generation from a centrifugal compressor. From the analysis of noise measurements, it is observed that Blade Passing Frequency noise related to the rotating impeller is more important, and it is focused on the comparison of this discrete frequency noise according to the shape change. Navier-Stokes solver is used to simulate the flow-field of the impeller and the vaned diffuser, and time-dependent pressure data are calculated and Fourier-transformed to perform the near-field noise prediction. The effects of various geometry design variables such as the gap between the impeller and the diffuser, impeller shape variations on the near-field noise distribution are investigated.