• Title/Summary/Keyword: 김주용

Search Result 498, Processing Time 0.03 seconds

Accelerating aging test of distribution lightning arresters (배전용 피뢰기의 가속열화시험)

  • 김주용;송일근;김찬영;이병성;문재덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.596-598
    • /
    • 2000
  • This paper presents a new accelerating aging test facility for distribution lightning arresters. Aging parameters of lightning arrester are moisture ingress, electrical stress and surge absorption and so on. In this system, we applied 13.2kV to 6 samples and controled temperature and humidity of chamber and measured leakage currents of the all samples. Also we developed accelerating aging cycle which consists of -35$^{\circ}C$∼90$^{\circ}C$ temperature and 40%∼90% humidity. Through the aging test we found out the leakage current of aged sample increases rapidly according to the temperature rising. Hereafter we can determine the replacement guide of leakage current for field operating arresters and condition assessment of aged samples through this aging test.

  • PDF

The Economic Evaluation based Design Program for the Off-Grid Microgrid (경제성평가 기반의 독립형 마이크로그리드 설계 프로그램 개발)

  • Lee, Hak-Ju;Chae, Woo-Kyu;Jung, Won-Wook;Kim, Ju-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.90-98
    • /
    • 2010
  • Microgrid is a small-scale power system composed of distributed generators, energy storage system and loads, and can operate in the grid-connected mode and the islanded mode. This paper presents optimal design procedures for remote microgrid. The design program is based on the economic evaluations including the feasibility study module, optimal combination and allocation of DERs, power network design and the reduction of the GHG emmission. This program which is suggested in this paper shows good performance as a tool of remote microgrid design.

Leakage Current Characteristics of 18kv ZnO Lightning Arresters by Accelerated Aging Test (가속열화시험에 의한 18kV ZnO 피뢰기의 누설 전류 특성 분석)

  • Kim, Ju-Yong;Song, Il-Geun;Kim, Chan-Yeong;Mun, Jae-Deok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • This paper provides the results of accelerated aging test of 18kV ZnO lightning arresters to investigate the leakage current characteristics. It was impossible to establish the replacement criterion for field operating lightning arrester because conventional aging test was only focused on the aging of ZnO elements. In general, it is possible to replace the aged arresters before the failure in the field using the leakage current measurement because it must be increased by the aging. But we can not use the method because we don't know the characteristics of the installed lightning arresters. Therefore in this paper we applied operating voltage and accelerating cycle which consists of temperature and humidity to the arresters. Then we measured the variation of total and resistive leakage current and found out the characteristics of the acted lightning arresters.

Characteristic Analysis of Suspension Insulators for Distribution Line (배전용 현수애자의 특성분석)

  • 김찬영;김주용;송일근;이병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.259-264
    • /
    • 2000
  • The paper provides the characteristic analyses of porcelain suspension insulators. The comparisons of characteristics were made as a function of failed and unfailed insulators which had ben used in the fields. This paper also describes the failure modes occurred in the fields. The aging of cement corrosion of metal breaking of shed puncture in the head and separation of glaze are different failure modes for porcelain suspension insulators. Among these failure modes the puncture breaking and glaze problems were major concerns in this research. The cracks porosities of porcelain and micro-crystals on the graze were the causes of these failures. These results were confirmed by conducting various failure analyses.

  • PDF

Analysis on power loss of three-phase soft switching inverter (3상 소프트 스위칭 인버터의 전력손실에 관한 해석)

  • Kim, J.Y.;Mun, S.P.;Kim, Y.S.;Suh, K.Y.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.3-5
    • /
    • 2002
  • This paper proposes a new prototype auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually measured conduction loss characteristic of switching device module. Voltage-type soft switching three phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF

Relation between Dielectric Diagnosis and ACBD Strength in URD Cables (배전케이블 진단결과와 교류절연파괴강도의 상관성)

  • 한재홍;김주용;김동명;이병성;정년호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.484-487
    • /
    • 2000
  • This study is for assessing a reliability of diagnostic device through comparing diagnostic results to ACDB strength. The dielectric diagnosis using IRC (isothermal relaxation current) measurement was carried on service-aged cables. From this study, there was little correlation between dielectric diagnosis and ACBD strength in long distance cables. But the correlation between them showed in short distance below 200 m. Therefore, it is desirable to diagnose the URD cables in short distance.

  • PDF

A Positioning Method of Droop Controlled Sources for Minimum Average Voltage Variation in a DC Microgrid (직류 마이크로그리드의 평균 전압 변동을 최소화하기 위한 드룹 제어 전원의 위치 선정 기법)

  • Ko, Byoung-Sun;Lee, Gi-Young;Kim, Rae-Young;Kim, Tae-Hoon;Kim, Ju-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.116-117
    • /
    • 2017
  • 본 논문에서는 전압 민감도를 통해 직류 마이크로그리드의 전압 변동을 최소화하기 위한 드룹 제어 전원의 위치 선정 기법을 제시한다. 전압 민감도를 도출하기 위해 전력 흐름 분석을 수행하였으며, 드룹 제어의 특성을 반영하기 위해 드룹 버스를 도입하였다. 그러나 드룹 버스를 적용함으로써 전력망의 전압 민감도는 드룹 제어 전원의 위치에 의존하게 된다. 따라서 드룹 제어 전원의 위치에 따른 전압 민감도를 분석하고 이를 비교하여 DC MG의 평균 전압 변동이 최소화되는 위치를 결정하였다. 제안한 드룹 제어 전원의 위치 선정 기법의 결과를 PSCAD/EMTDC 시뮬레이션을 통해 검증하였다.

  • PDF

Three Port NPC based DAB Converter for the Bipolar DC Grid (양극성 직류 배전망에 적용 가능한 3포트 기반의 DAB 컨버터)

  • Yun, Hyeok-Jin;Kim, Myoungho;Ryo, Myung-Hyo;Baek, Ju-Won;Kim, Ju-Yong;Kim, Hee-Je
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.351-352
    • /
    • 2017
  • 본 논문은 반도체 변압기에 사용되는 3포트 DC-DC 컨버터의 전력 전달 모델링에 대해서 다룬다. 이 DC-DC 컨버터는 고전압 입력에 대응하기 위해 3L-NPC 구조를 가진다. 또한, 양극성 배전망에 적용하기 위해 3권선 변압기와 2차측에 2개의 하프 브릿지 회로를 사용한다. 본 논문에서는 이 특수한 구조 때문에 발생하는 전력 전달 모델링의 복잡성을 단순화하기 위해 분리 행렬을 도입하였다. 제안하는 컨버터와 모델링의 성능은 시뮬레이션 및 15kW 반도체 변압기 시제품을 통해 검증하였다.

  • PDF

A study and implementation of a 30kV highly isolated DC-DC converter (30kV 절연성능을 갖는 고절연 DC-DC 컨버터에 관한 연구)

  • Kim, Jeongwoo;Bu, Hanyoung;Cho, Younghoon;Kim, Ho-Sung;Cho, Jintae
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.355-356
    • /
    • 2017
  • In this paper, a highly isolated DC-DC converter is designed as a power supply, and an insulator-molded transformer is used to achieve high insulation performance. Finally, the insulation performance of the power supply was verified by experimental results.

  • PDF

Thermal analysis of the active-front-end rectifier for solid-state-transformer applications (반도체 변압기용 AFE 정류기의 열해석 연구)

  • WANG, SHANSHAN;Kang, Kyoung Pil;Baek, Ju Won;Kim, juyong;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.435-436
    • /
    • 2017
  • This papaer is study on thermal analysis of the active-front-end(AFE) rectifier for solid-state-transformer(SST) applications. finite element analysis simulation model is combined by switching component model, power diode and heat-sink model. thermal model is calculated by computer program and feedback the result. using simulation result analysis switching loss and compare to thermal diffusion of the heat in the model for steady-state operation.

  • PDF