• Title/Summary/Keyword: 김용하

Search Result 1,769, Processing Time 0.023 seconds

A Study on Probabilistic Harmonic Filter Design (확률론적 고조파필터 설계에 관한 연구)

  • Kim, Y.H.;Lee, Buhm;Choi, S.K.;Lee, S.J.;Lee, M.M.;Na, I.K.;Lee, K.S.;Choi, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.465-467
    • /
    • 2005
  • Filter design for harmonic reduction suggests that measurement from IEEE std-519 and IEEE-61000 standards for 1 year designs filter about the worst case, filter design about method applied probability from IEEE std-519 standard suggests the basic alternative. At filter design method applied to temporary occurred harmonic maximum, analyzed into closely harmonic that applied to probability develops that ignorable harmonic that lowers temporary occurred probability is rational and economic filter design in detailed method.

  • PDF

Nodal price of the power system considering voltage and transient stability (전압안정도 및 과도 안정도틀 고려한 모선가격 산정)

  • Kim, Yong-Ha;Lee, Bum;Choi, Sang-Gyu;Jo, Sung-Lin;Jung, Hyeon-Sung;Oh, Suk-Hyeon;Kim, Dong-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.129-130
    • /
    • 2006
  • This paper presents a optimal power flow calculation algorithm considering voltage and transient stability. In this method, voltage stability margin and transient stability constraints is incorporated into a optimal power flow calculation formulation to guarantee adequate voltage and transient security levels in power system. In addition, this paper provides the Effect of Nodal Price and decomposed Element in Power System Operation. This Effect can be applied in the Estimation of Electric rates because the Electric market will be Competitive Market. The proposed method is applied to IEEE-24 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

A study on Estimation Method of Generation Cost for Planning for Combined Heat and Power (열병합발전의 계획발전원가 산정방법에 관한 연구)

  • Kim, Yong-Ha;Lee, Buhm;Choi, Sang-Kyu;Kim, Mi-Ye;Cho, Sung-Rin;Jung, Hyun-Sung;Yun, Jong-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.828-830
    • /
    • 2005
  • A index using generation cost for planning' for representing economical efficiency of generator, However in case of Combined heat and power(CHP) the product is divided in electrical power and steam, so there are no unconditional comparison between general generator and CHP. To calculating the generation cost for planning of CHP, this study using the method that change electrical power and steam into same unit and suggest the comparing system that can compare economical efficiency with other generators.

  • PDF

A Study on Effect Considering the Electricity Supply & Demand and Environment Using CHP (열병합발전이 전력수급 및 환경에 미치는 영향에 관한 연구)

  • Kim, Yong-Ha;Na, In-Gyu;Kim, Dong-Geun;Woo, Sung-Min;Kim, Mi-Ye;Lim, Hyun-Sung;Son, Seung-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.521-522
    • /
    • 2006
  • This paper calculates co-generation generating capacity for the electric supply and demand. CHP is applied to SCM(Screening Curve Method) to calculate CHP generating capacity On the other hand, small co-generation is applied to potential area conversing small co-generation generating capacity considering economic analysis and useful life. these methods executed project scheduled to construction plan. Accordingly, EES(Expected Energy Served), Fuel type consumption and CO2 effects is analyzed by Booth-Baleriaux and data

  • PDF

A Study on Priority Solution of ANP for Harmonic filter setting (ANP에 의한 고조파 필터설치의 우선순위 결정에 관한 연구)

  • Kim, Y.H.;Lee, Buhm;Choi, S.K.;Woo, S.M.;Hwang, B.S.;Kim, Y.T.;Im, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.468-470
    • /
    • 2005
  • This paper presents a method which can select optimal nodes to reduce harmonics by using ANP. First, we measured harmonics for the real distribution system and Tried to Analyze It. Second, we designed filters to reduce harmonics. Third, we composed each clusters and calculated it to select optimal nodes based on ANP. We a lied it to the distribution system, and deduce most advantageous method in many technical and economical among harmonic decrease measures. We proved the adequacy and usefulness of the result.

  • PDF

A Estimation Method for Ratio of Generator Composition included Combined Heat and Power Using Screening Curve Method (열병합발전이 고려된 심사곡선법에 의한 전원구성 비율 산정방법의 연구)

  • Kim, Yong-Ha;Lee, Buhm;Choi, Sang-Kyu;Kim, Mi-Ye;Yeon, Jun-Hee;Kim, Myung-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.736-738
    • /
    • 2005
  • For calculating optimal generation composition of The Basic Plan of Long Term Electricity Supply & Demand, the Screening Curve Method that using generation cost for planning is needed. This paper will induce optimal power system ratio included Combined Head and Power and suggest the method for optimal generation composition of The Basic Plan of Long Term Electricity Supply & Demand that considered policy side.

  • PDF

Research about composition of protective system in Co-Generation (PSCAD/EMTDC를 이용한 소형열병합발전 설비에서 보호계전시스템의 구성에 관한 연구)

  • Kim, Y.H.;Choi, S.K.;Lee, Bum;Lee, S.J.;Lee, K.S.;Park, N.C.;Lee, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.458-459
    • /
    • 2006
  • System has to be applied as protection at existent supply of electric power system and link is different from when system is operated individually Co-Generation. When equipment is driven Co-Generation that associate in existent equipment in this paper, displayed operating state of function by duty of protective system.

  • PDF

A Study to Calculation Industrial Customer Interruption Cost Using Value- Based Distribution Reliability Assessment (가치평가법에 의한 산업용 수용가의 공급지장비 산정에 관한 연구)

  • Kim, Yong-Ha;Park, Nam-Cheol;Lee, Bum;Shin, Hyoung-Cheol;Woo, Sung-Min;Leem, Hyun-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.408-410
    • /
    • 2006
  • This paper analyzes supply interruption cost for out industrial customer through data survey. And then we calculate SCDF using data survey. To decide the optimal SCDF, we decide regression function using AHP. Therefore we decide suitable SCDF of our industrial customer.

  • PDF

A Study on Development of Optimal Power Flow Calculation Algorithm Considering Voltage and Transient Stability (전압 및 과도안정도를 고려한 최적조류계산 알고리즘 개발에 관한 연구)

  • Kim, Yong-Ha;Lee, Buhm;Choi, Sang-Kyu;Cho, Sung-Rin;Jung, Hyun-Sung;Oh, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.39-42
    • /
    • 2005
  • This paper presents a optimal power flow calculation algorithm considering voltage and transient stability In this method, voltage stability margin and transient stability constraints is incorporated into a optimal power flow calculation formulation to guarantee adequate voltage and transient security levels in power system. The proposed method is applied to IEEE-24 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

Development of Quantitative Stability Evaluation Method for Electric Distribution System (전기설비 구성에 따른 배전시스템 안정성의 정량적 평가기법의 개발)

  • Kim, Yong-Ha;Lee, Buhm;Choi, Sang-Kyu;Choi, Young-Ju;Lee, Goang-Sung;Yeon, Jun-Hee;Im, Hyeon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.286-288
    • /
    • 2005
  • 본 논문에서는 전력의 품질요소 중 배전시스템의 운용에 많은 영향을 미치는 신뢰도, 전압Sag/Swell, 전압변동, 고조파를 하나의 종합화된 지수로 표시할 수 있도록 하여, 배전시스템의 품질을 정량적으로 표시할 수 있도록 하였다. 또한 시스템의 전력품질을 하나의 지수로 표현하기 위하여, 각 항목의 중요도를 도출하고, AHP에 의한 통할전력품질지수를 개발하였다.

  • PDF